Water vapor mass transport across nanofibrillated cellulose films: effect of surface hydrophobization

Cellulose ◽  
2017 ◽  
Vol 25 (1) ◽  
pp. 347-356 ◽  
Author(s):  
Iina Solala ◽  
Romain Bordes ◽  
Anette Larsson
2016 ◽  
Vol 51 (21) ◽  
pp. 9562-9572 ◽  
Author(s):  
V. L. D. Costa ◽  
A. P. Costa ◽  
M. E. Amaral ◽  
C. Oliveira ◽  
M. Gama ◽  
...  

2015 ◽  
Vol 50 (21) ◽  
pp. 6926-6934 ◽  
Author(s):  
Arttu Miettinen ◽  
Axel Ekman ◽  
Gary Chinga-Carrasco ◽  
Markku Kataja

2019 ◽  
Vol 147 (11) ◽  
pp. 4045-4069 ◽  
Author(s):  
Alexandre O. Fierro ◽  
Yunheng Wang ◽  
Jidong Gao ◽  
Edward R. Mansell

Abstract The assimilation of water vapor mass mixing ratio derived from total lightning data from the Geostationary Lightning Mapper (GLM) within a three-dimensional variational (3DVAR) system is evaluated for the analysis and short-term forecast (≤6 h) of a high-impact convective event over the northern Great Plains in the United States. Building on recent work, the lightning data assimilation (LDA) method adjusts water vapor mass mixing ratio within a fixed layer depth above the lifted condensation level by assuming nearly water-saturated conditions at observed lightning locations. In this algorithm, the total water vapor mass added by the LDA is balanced by an equal removal outside observed lightning locations. Additional refinements were also devised to partially alleviate the seasonal and geographical dependence of the original scheme. To gauge the added value of lightning, radar data (radial velocity and reflectivity) were also assimilated with or without lightning. Although the method was evaluated in quasi–real time for several high-impact weather events throughout 2018, this work will focus on one specific, illustrative severe weather case wherein the control simulation—which did not assimilate any data—was eventually able to initiate and forecast the majority of the observed storms. Given a relatively reasonable forecast in the control experiment, the GLM and radar assimilation experiments were still able to improve the short-term forecast of accumulated rainfall and composite radar reflectivity further, as measured by neighborhood-based metrics. These results held whether the simulations made use of one single 3DVAR analysis or high-frequency (10 min) successive cycling over a 1-h period.


2007 ◽  
Vol 96 (7) ◽  
pp. 1776-1793 ◽  
Author(s):  
Henning Gieseler ◽  
William J. Kessler ◽  
Michael Finson ◽  
Steven J. Davis ◽  
Phillip A. Mulhall ◽  
...  

CrystEngComm ◽  
2015 ◽  
Vol 17 (31) ◽  
pp. 5998-6005 ◽  
Author(s):  
Ilio Miccoli ◽  
Paola Prete ◽  
Nico Lovergine

The MOVPE growth dynamics of AlGaAs shell material around ensembles of free-standing GaAs nanowires is presented and described by a model based on the vapor mass-transport of group-III species and the nanowires relevant size (diameter, height) and density.


Author(s):  
Khaled Yousef ◽  
Ahmed Hegazy ◽  
Abraham Engeda

Abstract Computational Fluid Dynamics (CFD) for air/water-vapor and water-liquid two-phase flow mixing with condensation in a vertical inverted U-tube is presented in this paper. This study is to investigate the flow behaviors and underlying some physical mechanisms encountered in air/water-vapor and water-liquid mixing flow when condensation is considered. Water-liquid flows upward-downward through the inverted U-tube while the air/water-vapor mixture is extracted from a side-tube just after the flow oriented downward. The CFD simulation is carried out for a side air/water-vapor mixture volume fraction (αm) of 0.2–0.7, water-vapor mass fraction (Xv) of 0.1–0.5 in the side air/water-vapor mixture and water-liquid mass flowrate (mw) of 2,4,6, and 8 kg/s. The present results reveal that, at lower air mass flow rate, no significant effect of Xv on the generated static pressure at the inverted U-tube higher part. However, by increasing the air mass flow rates, ma ≥ 0.001 at mw = 2 kg/s, and ma ≥ 0.00125 at mw = 4 kg/s, we can infer that the lowest static pressure can be attained at Xv = 0.1. This may be attributed to the increased vapor and air mass flow rates from the side tube which results in shifting the condensation from the tube highest part due to air accumulation. This leads to increasing the flow pressure and decelerating the water-liquid flow. Raising mw from 2 to 4 kg/s at the same vapor mass ratio results in a lower static pressure due to more condensation of water vapor. The turbulent intensity and kinetic energy starts to drop approximately at ma = 0.002 kg/s, and αm = 0.55–0.76 at mw = 2 kg/s for all Xv values but no noticeable change at mw = 4 kg/s occurs. These findings estimate the operational values of air and water mass flow rates for stable air entrainment from the side-tube. Increasing the air and vapor mass ratio over these values may block the evacuation process and fails the system continuance. Likewise more air entrainment from the side-tube will decelerate the water flow through the inverted U-tube and hence the flow velocity will decrease thereafter. Moreover, this study reveals that the inverted U-tube is able to generate a vacuum pressure down to 55.104 kPa for the present model when vapor condensation is considered. This generated low-pressure helps to vent an engineering system from the non-condensable gases and water vapor that fail its function if these are accumulated with time. Moreover, the water-liquid mass flow rate in the inverted U-tube can be used to sustain the required operating pressure for this system and extract the non-condensable gases with a less energy consuming system. The present CFD model provides a good physical understanding of the flow behavior for air/water-vapor and water-liquid flow for possible future application in the steam power plant.


Sign in / Sign up

Export Citation Format

Share Document