Multifunctional n-ZnO/MoO3/PEDOT:PSS-based hybrid device for high-speed UV light detection and ReRAM applications

Author(s):  
Asif Rasool ◽  
R. Amiruddin ◽  
Shahnaz Kossar ◽  
MC Santhosh Kumar
Author(s):  
Surajit Das ◽  
Ashok Kumar ◽  
Ajay Kumar ◽  
Jitendra Singh ◽  
Rajan Jha ◽  
...  

2017 ◽  
Vol 140 (3) ◽  
Author(s):  
Husain Al Hashimi ◽  
Caleb F. Hammer ◽  
Michel T. Lebon ◽  
Dan Zhang ◽  
Jungho Kim

Techniques based on temperature-sensitive paints (TSP) to measure time-resolved temperature and heat transfer distributions at the interface between a wall and fluid during pool and flow boiling are described. The paints are excited using ultraviolet (UV) light emitting diodes (LEDs), and changes in fluorescence intensity are used to infer local temperature differences across a thin insulator from which heat flux distribution is obtained. Advantages over infrared (IR) thermometry include the ability to use substrates that are opaque to IR (e.g., glass, plexiglass and plastic films), use of low-cost optical cameras, no self-emission from substrates to complicate data interpretation, high speed, and high spatial resolution. TSP-based methods to measure wall heat transfer distributions are validated and then demonstrated for pool and flow boiling.


2015 ◽  
Vol 10 (05) ◽  
pp. P05008-P05008 ◽  
Author(s):  
S. Magill ◽  
M. Nayfeh ◽  
M. Fizari ◽  
J. Malloy ◽  
Y. Maximenko ◽  
...  

Author(s):  
Ting Yu ◽  
Tushar Chaitanya

MV (Medium Voltage) controller lineup electrical protection is crucial in protecting the equipment from large scale damage upon the occurrence of an electrical fault, reducing the time to restore power, thereby minimizing the impact to liquids pipelines operation. The paper discusses typical electrical failure modes that may occur in MV controller lineups, and demonstrates practical relaying engineering techniques that enable fast and effective fault clearing. Electrical faults in the MV controller lineup are often arcing type, commonly involve ground. Mitigating arc hazards in MV Class E2 controller lineups has traditionally been challenging without sacrificing the protection selectivity. As the paper demonstrates, a relaying scheme with the combined use of high-speed light-sensing and overcurrent detection will effectively mitigate the incident energy, while maintaining the protection selectivity for non-arcing overcurrent events. For new MV controller lineups, in addition to the “high-speed light detection and fault interruption”, zone-selective interlocking (ZSI) can also be a practical solution in improving relay protection speed, thus reduce the chance of severe arc flash occurrences. ZSI is particularly effective for fault occurrences on the line side of the phase CTs, busways or main incoming circuits. The ZSI scheme can be implemented on both Class E2 and circuit breaker (VCB) type MV controller lineups, however, with slightly different trip logic due to the limited fault clearing capability of the contactor. Although there are multiple contributing factors, the direct causes of electrical failures in MV controller lineup are commonly related to improper power cable installation and handling, potentially leading to premature insulation breakdown due mainly to the proximity effect and/or partial discharge. Inadequate cable separation and prolonged fault trip delay can increase the possibility of arcing fault occurrence. This can usually be mitigated through appropriate cable spacing, adequate conductor insulation, and optimized fault detection schemes. The paper provides overviews of the mechanisms of proximity effect and partial discharge propagation, and the modern relaying approaches for accurate fault type discrimination and facilitating fast fault interruption. Two case studies are provided in the paper as an aid in understanding the electrical fault mechanism originated from cable insulation failure, demonstrating the incident energy reduction before and after the implementation of high-speed light detection and fault interruption solutions on an existing MV controller lineup.


2020 ◽  
Author(s):  
Matteo Battisti ◽  
Enrico Arnone ◽  
Mario Bertaina ◽  
Marco Casolino ◽  
Olivier Chanrion ◽  
...  

<p>The search for the physical mechanisms of lightning, transient luminous events and terrestrial gamma-ray flashes is receiving an extraordinary support by new space observations that have recently become available. Next to lightning detectors on geostationary satellites, new low orbit experiments are giving an unprecedented insight in the very source of these processes. Looking at the physics behind these new observations requires however to have a variety of different instruments covering the same event, and this is proving extremely challenging. Here, we present observations of UV emissions of elves and lightning taken for the first time simultaneously from the two instruments Mini-EUSO and ASIM operating on the international space station. Mini-EUSO was designed to perform observations of the UV-light night emission from Earth. It is a wide field of view telescope (44°x44° square FOV) installed for the first time on October 2019 inside the Zvezda Module of the ISS, looking nadir through a UV transparent window. Its optical system consists of two Fresnel lenses for light collection. The light is focused onto an array of 36 multi-anode photomultiplier tubes (MAPMT), for a total of 2304 pixels. Each pixel has a footprint on ground of ~5.5 km. The instrument is capable of single-photon counting on three different timescales: a 2.5 microsecond (D1) and a 320 microsecond (D2) timescale with a dedicated trigger system, and a 40.96ms timescale (D3) used to produce a continuous monitoring of the UV emission from the Earth. ASIM is an experiment dedicated to lightning and atmospheric processes. Its Modular Multispectral Imaging Array (MMIA) is made of an array of 3 high speed photometers probing different wavelength sampling at rates up to 100 kHz, and 2 Electron Multiplication Charge Coupled Devices (EM-CCDs) with a sub-km spatial resolution with an 80° FOV and recording up to 12 frames per second. Mini-EUSO detected several bright atmospheric events like lightning and elves, with a few km spatial resolution and different time resolutions, probing therefore different stages of the electromagnetic phenomena. Observations from Mini-EUSO were simultaneously captured by ASIM instruments, allowing for the first time to compare and complement the capabilities of the two instruments with a time inter-calibration based on unambiguous series of lightning detections.</p>


2015 ◽  
Vol 222 ◽  
pp. 255-261 ◽  
Author(s):  
Praveen Kumar Shahi ◽  
A.K. Singh ◽  
S.B. Rai ◽  
Bruno Ullrich

Nanoscale ◽  
2018 ◽  
Vol 10 (40) ◽  
pp. 18926-18935 ◽  
Author(s):  
Hakan Selvi ◽  
Ernie W. Hill ◽  
Patrick Parkinson ◽  
Tim J. Echtermeyer

Graphene–silicon-on-insulator (GSOI) photodetectors for high-speed free space light detection.


Sign in / Sign up

Export Citation Format

Share Document