scholarly journals Validity of the Empatica E4 Wristband to Measure Heart Rate Variability (HRV) Parameters: a Comparison to Electrocardiography (ECG)

2020 ◽  
Vol 44 (11) ◽  
Author(s):  
Angela A. T. Schuurmans ◽  
Peter de Looff ◽  
Karin S. Nijhof ◽  
Catarina Rosada ◽  
Ron H. J. Scholte ◽  
...  

Abstract Wearable monitoring devices are an innovative way to measure heart rate (HR) and heart rate variability (HRV), however, there is still debate about the validity of these wearables. This study aimed to validate the accuracy and predictive value of the Empatica E4 wristband against the VU University Ambulatory Monitoring System (VU-AMS) in a clinical population of traumatized adolescents in residential care. A sample of 345 recordings of both the Empatica E4 wristband and the VU-AMS was derived from a feasibility study that included fifteen participants. They wore both devices during two experimental testing and twelve intervention sessions. We used correlations, cross-correlations, Mann-Whitney tests, difference factors, Bland-Altman plots, and Limits of Agreement to evaluate differences in outcomes between devices. Significant correlations were found between Empatica E4 and VU-AMS recordings for HR, SDNN, RMSSD, and HF recordings. There was a significant difference between the devices for all parameters but HR, although effect sizes were small for SDNN, LF, and HF. For all parameters but RMSSD, testing outcomes of the two devices led to the same conclusions regarding significance. The Empatica E4 wristband provides a new opportunity to measure HRV in an unobtrusive way. Results of this study indicate the potential of the Empatica E4 as a practical and valid tool for research on HR and HRV under non-movement conditions. While more research needs to be conducted, this study could be considered as a first step to support the use of HRV recordings provided by wearables.

2021 ◽  
Vol 38 (3) ◽  
pp. 192-199
Author(s):  
Ji-Min Hwang ◽  
Jun-Yeon Kim ◽  
Ha-Na Kim ◽  
Kyeong-Ju Park ◽  
Min-Gi Jo ◽  
...  

Background: In this retrospective study, we aimed to determine which diagnostic tests were associated with an improvement in Bell’s palsy symptoms. Methods: There were 30 patients who visited Kyung Hee University Korean Medicine Hospital from April 1, 2017 to February 29, 2020, and who received East-West collaboration treatment for Bell’s palsy. The tests included electroneurography (ENoG), electromyography (EMG), hematology, and heart rate variability (HRV) results which were used to determine if any test correlated with improvement of Bell’s palsy symptoms. Results: The initial severity of symptoms did not correlate with the tests performed, with the exception of mean corpuscular hemoglobin concentration (p = 0.013). For both ENoG for oculi degeneration and mean EMG tests, the rate of nerve degeneration showed a significant negative correlation with the improvement of Bell’s palsy symptoms. Amongst the HRV test indicators, the square root of the mean of the sum of the squares of differences between the adjacent normal R-R wave interval, the standard deviation of intervals, total power, very low frequency, and high frequency of the wave was negatively correlated with improvement of Bell’s palsy symptoms. Similarly, glycosylated hemoglobin Type A1c (HbA1c) and erythrocyte sedimentation rate (ESR) showed a negative correlation with improvement of symptoms of Bell’s palsy. With the exception of HbA1c and ESR, the remaining hematology test results showed no significant difference when comparing before and after treatment. Conclusion: ENoG, EMG, HRV test, HbA1c, and ESR negatively correlated with improvements in Bell’s palsy symptoms and may determine the prognosis of Bell’s palsy.


2021 ◽  
Vol 21 (1) ◽  
pp. 61-68
Author(s):  
Lyubomyr Vovkanych ◽  
Yuriy Boretsky ◽  
Viktor Sokolovsky ◽  
Dzvenyslava Berhtraum ◽  
Stanislav Kras

The study purpose was estimation of the accuracy of RR time series measurements by SHC “Rytm” and validity of derived heart rate variability (HRV) indexes under physical loads and recovery period. Materials and methods. The participants were 20 healthy male adults aged 19.7 ± 0.23 years. Data was recorded simultaneously with CardioLab CE12, Polar RS800, and SHC “Rytm”. Test protocol included a 2 minute step test (20 steps per minute, platform height – 40 cm) with the next 3 minute recovery period. HRV indexes were calculated by Kubios HRV 2.1. Results. The RR data bias in the case of physical loads was -0.06 ms, it increased to 0.09-0.33 ms during the recovery period. The limits of agreement for RR data ranged from 3.7 ms to 22.8 ms, depending on the period of measurements and pair of compared devices. It is acceptable for the heart rate and HRV estimation. The intraclass correlation coefficients (0.62–1.00) and Spearman correlation coefficient (0.99) were high enough to suggest very high repeatability of the data. We found no significant difference (p > 0.05) and good correlation (r = 0.94-1.00) between the majority of HRV indexes, calculated from data of Polar RS800 and SHC “Rytm” in conditions of physical loads (except for LF/HF ratio) and in the recovery period. The only one index (RMSSD) was different (p < 0.05) in case of Polar RS800 and SHC “Rytm” data, obtained in the recovery period. The largest numbers of different HRV indexes have been found during the comparison of CardioLab CE12 and Polar RS800 – RMSSD, pNN50, and SD1. Correlation between HRV indexes (r = 0.81-1.00) was very high in all pairs of devices in all periods of measurements. Conclusions. The SHC “Rytm” appears to be acceptable for RR intervals registration and the HRV analysis during physical loads and recovery period.


2018 ◽  
Vol 80 (1-2) ◽  
pp. 50-54 ◽  
Author(s):  
Masafumi Nozoe ◽  
Miho Yamamoto ◽  
Miki Kobayashi ◽  
Masashi Kanai ◽  
Hiroki Kubo ◽  
...  

Autonomic dysfunction is one of the predictors of poor outcome in patients with acute ischemic stroke. We compared the heart rate variability (HRV) during early mobilization in patients with or without neurological deterioration (ND). We enrolled 7 acute ischemic patients with ND and 14 without ND and measured their HRV in the rest and mobilization by electrocardiography. There was a significant difference in sympathetic nervous activity during mobilization between the 2 groups. However, no significant differences in blood pressure, heart rate, and parasympathetic nerve activity were observed. In patients with acute ischemic stroke, it is likely that the increase in sympathetic nervous activity during mobilization is associated with ND.


2021 ◽  
Vol 6 (3) ◽  
pp. 413-421
Author(s):  
Sapna Yadav ◽  
Gaurav Kadyan

Background: This study aimed to compare and correlate the resting heart rate, body composition and heart rate variability among judo and wushu players. Method: 40 athletes (20 judo and 20 wushu players) were included in the study. Body composition (BMI, subcutaneous body mass, skeletal body mass, body fat %, body density, Visceral fat, Lean body mass) was evaluated with the help of 7 skinfold thickness and body circumferences with the help of Harpenden calliper and measuring tape respectively. HRV (RMSSD, SDNN, LF/HF, LFnu and HFnu) was recorded in resting state (~5min) with the help of Heart wear shimmer ECG device. Result: No significant difference of body composition and HRV variables (p> 0.05) was found between the two groups except Body fat % and body density (p<0.05) which differ significantly among the two groups. In Judo, LF/HF and LFnu showed significant positive correlation with BMI (p<0.05, r=-0.488), subcutaneous whole-body mass (p<0.05, r=-0.464), visceral fat (p<0.05, r =-0.508), and body fat % (p<0.05, r =-0.626. Whereas HFnu showed significant negative correlation with BMI (p<0.05, r=-0.488), subcutaneous whole-body mass (p<0.05, r=-0.464), visceral fat (p<0.05, r=-0.505) and body fat % (p<0.05, r=-0.626). Whereas no correlation was found between HRV and Body composition in wushu players. Conclusion: Reduction in body fat % and visceral fat in judo players indicate improved sympathovagal balance which can be due to the adaptation induced by training loads. Similar results were not seen in wushu players because of high amount of body fat% and visceral fat. Keywords: Body composition, combat sports, heart rate variability, Body fat %, resting heart rate.


Pharmacology ◽  
2019 ◽  
Vol 104 (1-2) ◽  
pp. 1-6
Author(s):  
Alfredo Costa ◽  
Daniele Bosone ◽  
Matteo Cotta Ramusino ◽  
Giulia Perini ◽  
Natascia Ghiotto ◽  
...  

Aim: To assess the effects of chronic evening oral administration of bromazepam alone or in combination with propranolol on ambulatory blood pressure (BP) and heart rate (HR) in mild hypertensive subjects. Methods: Thirty-seven mild hypertensive patients after a 2-week placebo period were randomized to bromazepam 3 mg, propranolol 40 mg, bromazepam 3 mg plus propranolol 40 mg or placebo for 2 weeks according to a double-blind, double dummy, cross-over design. After each treatment period, 24-h BP and HR ambulatory monitoring was performed by using a non-invasive device. Results: Ambulatory monitoring showed that during night-time SBP and DBP values were unaffected by bromazepam as compared to placebo, whereas SBP was significantly reduced by propranolol both when taken alone and in combination with bromazepam. HR nocturnal values were significantly reduced by propranolol, whereas they were significantly increased by bromazepan both when taken alone (+11.5%, p < 0.05 vs. placebo) and in combination with propranolol (+12.8%, p < 0.05 vs. propranolol). No significant difference in day-time values of SBP, DBP and HR was observed among the 4 treatment groups. Conclusions: In mild hypertensive patients, evening consumption of bromazepam for a 2-week period did not affect BP, while it increased nocturnal HR. Such an increase was observed both when bromazepam was taken alone and in combination with propranolol, which suggests that it depends on a bromazepam mediated decrease in vagal tone. Whatever the mechanism, the HR nocturnal increase might be of clinical relevance, due to the role of high HR as cardiovascular risk factor, particularly in already at risk hypertensive subjects.


2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Eduardo Marcel Fernandes Nascimento ◽  
Diego Antunes ◽  
Paulo Cesar do Nascimento Salvador ◽  
Fernando Klitzke Borszcz ◽  
Ricardo Dantas de Lucas

Introduction. The purpose of this study was to evaluate the application of the Dmax method on heart rate variability (HRV) to estimate the lactate thresholds (LT), during a maximal incremental running test (MIRT). Methods. Nineteen male runners performed two MIRTs, with the initial speed at 8 km·h−1 and increments of 1 km·h−1 every 3 minutes, until exhaustion. Measures of HRV and blood lactate concentrations were obtained, and lactate (LT1 and LT2) and HRV (HRVTDMAX1 and HRVTDMAX2) thresholds were identified. ANOVA with Scheffe’s post hoc test, effect sizes (d), the bias ± 95% limits of agreement (LoA), standard error of the estimate (SEE), Pearson’s (r), and intraclass correlation coefficient (ICC) were calculated to assess validity. Results. No significant differences were observed between HRVTDMAX1 and LT1 when expressed for speed (12.1 ± 1.4 km·h−1 and 11.2 ± 2.1 km·h−1; p=0.55; d = 0.45; r = 0.46; bias ± LoA = 0.8 ± 3.7 km·h−1; SEE = 1.2 km·h−1 (95% CI, 0.9–1.9)). Significant differences were observed between HRVTDMAX2 and LT2 when expressed for speed (12.0 ± 1.2 km·h−1 and 14.1 ± 2.5 km·h−1; p=0.00; d = 1.21; r = 0.48; bias ± LoA = −1.0 ± 1.8 km·h−1; SEE = 1.1 km·h−1 (95% CI, 0.8–1.6)), respectively. Reproducibility values were found for the LT1 (ICC = 0.90; bias ± LoA = −0.7 ± 2.0 km·h−1), LT2 (ICC = 0.97; bias ± LoA = −0.1 ± 1.1 km·h−1), HRVTDMAX1 (ICC = 0.48; bias ± LoA = −0.2 ± 3.4 km·h−1), and HRVTDMAX2 (ICC = 0.30; bias ± LoA = 0.3 ± 3.5 km·h−1). Conclusions. The Dmax method applied over a HRV dataset allowed the identification of LT1 that is close to aerobic threshold, during a MIRT.


Biofeedback ◽  
2016 ◽  
Vol 44 (4) ◽  
pp. 229-233 ◽  
Author(s):  
Fredric Shaffer ◽  
Steven Shearman ◽  
Zachary M. Meehan

Researchers have investigated whether ultra-short-term (UST) heart rate variability values can replace traditional 5-minute values in clinical and optimal performance settings. Concurrent validity is the extent to which the results of a measurement correspond to a previously validated assessment of the same construct. Several studies either failed to specify their concurrent validity criteria or used an inappropriate statistical test. The authors proposed a rigorous standard and demonstrated that artifacted resting ultra-short-term heart rate variability values can achieve strong concurrent validity for diverse time-domain, frequency-domain, and nonlinear measurements in healthy undergraduates. Based on these findings, resting baselines as brief as 1 minute should be sufficient to measure heart rate, the standard deviation of the interbeat interval for normal beats (SDNN), and the square root of the mean squared difference of adjacent NN intervals (RMSSD) in clinical, optimal performance, and personal health assessment with individuals who resemble Truman State University undergraduates.


2008 ◽  
Vol 17 (6) ◽  
pp. 575-583 ◽  
Author(s):  
Shih-Fong Huang ◽  
Po-Yi Tsai ◽  
Wen-Hsu Sung ◽  
Chih-Yung Lin ◽  
Tien-Yow Chuang

Sympathovagal modulation during immersion in a virtual environment is an important influence on human performance of a task. The aim of this study is to investigate sympathovagal modulation using heart rate variability and perceived exertion during exercise in a virtual reality (VR) environment. Sixteen young healthy volunteers were tested while using a stationary bicycle and maintained at an anaerobic threshold intensity for exercise sessions of approximately 10 min duration. Four randomized viewing alternatives were provided including desktop monitor, projector, head mounted device (HMD), and no simulation display. The “no simulation display” served as the control group. A quick ramp exercise test was conducted and maintained at an anaerobic threshold intensity for each session to evaluate power spectral density and rating of perceived exertion (RPE). The sampled heart rate data were rearranged by cubic spline interpolation into power spectrums spanning the ultra-low frequency (ULF) to high frequency (HF) range. A significant difference was found between the no-display and projector groups for total power (TP) and very low frequency (VLF) components. In particular, there was a significant difference when comparing HMD and no-display exercise RPE curves within 6 min of cycling and at the termination of the exercise. A significant difference was also achieved in projector vs. control group comparison at the termination of the exercise. Our results indicate that the use of HMD and the projected VR during cycling can reduce the TP and VLF power spectral density through a proposed decrease in the renin-angiotensin system, with the implication that this humoral effect may enable anaerobic exercise for longer durations through a reduction in sympathetic tone and subsequent increased blood flow to the muscles.


2011 ◽  
Vol 26 (S2) ◽  
pp. 147-147
Author(s):  
T. Diveky ◽  
D. Kamaradova ◽  
A. Grambal ◽  
K. Latalova ◽  
J. Prasko ◽  
...  

The aim of our study is to measure very low frequency band (VLF), low frequency band (LF) and high frequency band (HF) components of R-R interval during orthostatic experiment in panic disorder patients before and after treatment.MethodsWe assessed heart rate variability in 19 patients with panic disorder before and after 6-weeks treatment with antidepressants combined with CBT and 18 healthy controls. They were regularly assessed on the CGI, BAI and BDI. Heart rate variability was assessed during 5 min standing, 5 min supine and 5 min standing positions before and after the treatment. Power spectra were computed using a fast Fourier transformation for very low frequency - VLF (0.0033 - 0.04 Hz), low-frequency - LF (0.04-0.15 Hz) and high frequency - HF (0.15-0.40 Hz) powers.Results19 panic disorder patients entered a 6-week open-label treatment study with combination of SSRI and cognitive behavioral therapy. A combination of CBT and pharmacotherapy proved to be the effective treatment of patients. They significantly improved in all rating scales. There were highly statistical significant differences between panic patients and control group in all components of power spectral analysis in 2nd and in two component of 3rd (LF and HF in standing) positions. There was also statistically significant difference between these two groups in LF/HF ratio in supine position (2nd). During therapy there was tendency to increasing values in all three positions in components of HRV power spectra, but there was only statistically significant increasing in HF1 component.Supported by project IGA MZ ČR NS 10301-3/2009


Sign in / Sign up

Export Citation Format

Share Document