scholarly journals Applicability of Dmax Method on Heart Rate Variability to Estimate the Lactate Thresholds in Male Runners

2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Eduardo Marcel Fernandes Nascimento ◽  
Diego Antunes ◽  
Paulo Cesar do Nascimento Salvador ◽  
Fernando Klitzke Borszcz ◽  
Ricardo Dantas de Lucas

Introduction. The purpose of this study was to evaluate the application of the Dmax method on heart rate variability (HRV) to estimate the lactate thresholds (LT), during a maximal incremental running test (MIRT). Methods. Nineteen male runners performed two MIRTs, with the initial speed at 8 km·h−1 and increments of 1 km·h−1 every 3 minutes, until exhaustion. Measures of HRV and blood lactate concentrations were obtained, and lactate (LT1 and LT2) and HRV (HRVTDMAX1 and HRVTDMAX2) thresholds were identified. ANOVA with Scheffe’s post hoc test, effect sizes (d), the bias ± 95% limits of agreement (LoA), standard error of the estimate (SEE), Pearson’s (r), and intraclass correlation coefficient (ICC) were calculated to assess validity. Results. No significant differences were observed between HRVTDMAX1 and LT1 when expressed for speed (12.1 ± 1.4 km·h−1 and 11.2 ± 2.1 km·h−1; p=0.55; d = 0.45; r = 0.46; bias ± LoA = 0.8 ± 3.7 km·h−1; SEE = 1.2 km·h−1 (95% CI, 0.9–1.9)). Significant differences were observed between HRVTDMAX2 and LT2 when expressed for speed (12.0 ± 1.2 km·h−1 and 14.1 ± 2.5 km·h−1; p=0.00; d = 1.21; r = 0.48; bias ± LoA = −1.0 ± 1.8 km·h−1; SEE = 1.1 km·h−1 (95% CI, 0.8–1.6)), respectively. Reproducibility values were found for the LT1 (ICC = 0.90; bias ± LoA = −0.7 ± 2.0 km·h−1), LT2 (ICC = 0.97; bias ± LoA = −0.1 ± 1.1 km·h−1), HRVTDMAX1 (ICC = 0.48; bias ± LoA = −0.2 ± 3.4 km·h−1), and HRVTDMAX2 (ICC = 0.30; bias ± LoA = 0.3 ± 3.5 km·h−1). Conclusions. The Dmax method applied over a HRV dataset allowed the identification of LT1 that is close to aerobic threshold, during a MIRT.

2021 ◽  
Vol 21 (1) ◽  
pp. 61-68
Author(s):  
Lyubomyr Vovkanych ◽  
Yuriy Boretsky ◽  
Viktor Sokolovsky ◽  
Dzvenyslava Berhtraum ◽  
Stanislav Kras

The study purpose was estimation of the accuracy of RR time series measurements by SHC “Rytm” and validity of derived heart rate variability (HRV) indexes under physical loads and recovery period. Materials and methods. The participants were 20 healthy male adults aged 19.7 ± 0.23 years. Data was recorded simultaneously with CardioLab CE12, Polar RS800, and SHC “Rytm”. Test protocol included a 2 minute step test (20 steps per minute, platform height – 40 cm) with the next 3 minute recovery period. HRV indexes were calculated by Kubios HRV 2.1. Results. The RR data bias in the case of physical loads was -0.06 ms, it increased to 0.09-0.33 ms during the recovery period. The limits of agreement for RR data ranged from 3.7 ms to 22.8 ms, depending on the period of measurements and pair of compared devices. It is acceptable for the heart rate and HRV estimation. The intraclass correlation coefficients (0.62–1.00) and Spearman correlation coefficient (0.99) were high enough to suggest very high repeatability of the data. We found no significant difference (p > 0.05) and good correlation (r = 0.94-1.00) between the majority of HRV indexes, calculated from data of Polar RS800 and SHC “Rytm” in conditions of physical loads (except for LF/HF ratio) and in the recovery period. The only one index (RMSSD) was different (p < 0.05) in case of Polar RS800 and SHC “Rytm” data, obtained in the recovery period. The largest numbers of different HRV indexes have been found during the comparison of CardioLab CE12 and Polar RS800 – RMSSD, pNN50, and SD1. Correlation between HRV indexes (r = 0.81-1.00) was very high in all pairs of devices in all periods of measurements. Conclusions. The SHC “Rytm” appears to be acceptable for RR intervals registration and the HRV analysis during physical loads and recovery period.


2014 ◽  
Vol 46 ◽  
pp. 340
Author(s):  
Nauris Tamulevicius ◽  
Martinique Sparks ◽  
Sarah J. Moss ◽  
Michiel R. de Boer ◽  
Harvey Campbell

Author(s):  
Júlia Halamová ◽  
Jana Koróniová ◽  
Martin Kanovský ◽  
Mária Kénesy Túniyová ◽  
Nuriye Kupeli

Emotion Focused Training for Self-Compassion and Self-Protection (EFT-SCP) is a novel intervention developed on the basis of the latest findings on self-criticism from Emotion-focused therapy and existing programs designed to cultivate compassion. EFT-SCP is designed to encourage participants to cultivate self-compassion and protective anger as a way of reducing selfcriticism. Our goal was to investigate the effect of this group-based intervention on self-criticism, self-protection, and self-compassion. A total of 73 students were assigned to the EFT-SCP intervention (n=19), no-treatment control (n=34) or to an active control group (n=20). The intervention group met weekly for 1.5 hours and were instructed to incorporate EFT-SCP tasks into their daily life for 12 weeks. Whilst the no-treatment group did not undergo an intervention, the active control group completed an adapted expressive writing task once a week. In addition to the assessment of heart rate variability during imagery tasks, participants also completed self-reported measures of self-compassion and self-criticism before and after the intervention. Compared with both control groups, the intervention group showed a significant increase in heart rate variability following EFT-SCP (during self-critical imagery, P=.049; probability of superiority was .63, and during self-compassionate imagery P=.007; probability of superiority was .62, both effect sizes were medium) and significant decreases in self-criticism (Hated Self P=.017; .34 and Inadequate Self P<.001; .33) and selfuncompassionate responding (P<.001; .39). All three effect sizes were small. Participating in EFT-SCP had a positive effect on psychological and physiological outcomes.


2016 ◽  
Vol 37 (5) ◽  
pp. 536-543 ◽  
Author(s):  
Rosangela Akemi Hoshi ◽  
Luiz Carlos Marques Vanderlei ◽  
Moacir Fernandes de Godoy ◽  
Fábio do Nascimento Bastos ◽  
Jayme Netto ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Bruce Rogers ◽  
David Giles ◽  
Nick Draper ◽  
Olaf Hoos ◽  
Thomas Gronwald

The short-term scaling exponent alpha1 of detrended fluctuation analysis (DFA a1), a nonlinear index of heart rate variability (HRV) based on fractal correlation properties, has been shown to steadily change with increasing exercise intensity. To date, no study has specifically examined using the behavior of this index as a method for defining a low intensity exercise zone. The aim of this report is to compare both oxygen intake (VO2) and heart rate (HR) reached at the first ventilatory threshold (VT1), a well-established delimiter of low intensity exercise, to those derived from a predefined DFA a1 transitional value. Gas exchange and HRV data were obtained from 15 participants during an incremental treadmill run. Comparison of both VO2 and HR reached at VT1 defined by gas exchange (VT1 GAS) was made to those parameters derived from analysis of DFA a1 reaching a value of 0.75 (HRVT). Based on Bland Altman analysis, linear regression, intraclass correlation (ICC) and t testing, there was strong agreement between VT1 GAS and HRVT as measured by both HR and VO2. Mean VT1 GAS was reached at 39.8 ml/kg/min with a HR of 152 bpm compared to mean HRVT which was reached at 40.1 ml/kg/min with a HR of 154 bpm. Strong linear relationships were seen between test modalities, with Pearson’s r values of 0.99 (p &lt; 0.001) and.97 (p &lt; 0.001) for VO2 and HR comparisons, respectively. Intraclass correlation between VT1 GAS and HRVT was 0.99 for VO2 and 0.96 for HR. In addition, comparison of VT1 GAS and HRVT showed no differences by t testing, also supporting the method validity. In conclusion, it appears that reaching a DFA a1 value of 0.75 on an incremental treadmill test is closely associated with crossing the first ventilatory threshold. As training intensity below the first ventilatory threshold is felt to have great importance for endurance sport, utilization of DFA a1 activity may provide guidance for a valid low training zone.


Author(s):  
Joel S. Burma ◽  
Sarah Graver ◽  
Lauren N. Miutz ◽  
Alannah Macaulay ◽  
Paige V. Copeland ◽  
...  

Background: Ultra-short-term (UST) heart rate variability (HRV) metrics have increasingly been proposed as surrogates for short-term HRV metrics. However, the concurrent validity, within-day reliability, and between-day reliability of UST HRV have yet to be comprehensively documented. Methods: Thirty-six adults (18 males, age: 26 ± 5 years, BMI: 24 ± 3 kg/m2) were recruited. Measures of HRV were quantified in a quiet-stance upright orthostatic position via three-lead electrocardiogram (ADInstruments, FE232 BioAmp). All short-term data recordings were 300-seconds in length and five UST time points (i.e., 30-seconds, 60-seconds, 120-seconds, 180-seconds, and 240-seconds) were extracted from the original 300-second recording. Bland-Altman plots with 95% limits of agreement, repeated measures ANOVA, and two-tailed paired t-tests demarcated differences between UST and short-term recordings. Linear regressions, coefficient of variation, intraclass correlation coefficients, and other tests examined the validity and reliability in both time- and frequency-domains. Results: No group differences were noted between all short-term and UST measures, for either time- (all p>0.202) or frequency-domain metrics (all p>0.086). A longer recording duration was associated with augmented validity and reliability, that was less impacted by confounding influences from physiological variables (e.g., respiration rate, carbon dioxide end-tidals, and blood pressure). Conclusively, heart rate, time-domain, and relative frequency-domain HRV metrics were acceptable with recordings greater or equal to 60s, 240s, and 300s, respectively. Conclusions: Future studies employing UST HRV metrics, should thoroughly understand the methodological requirements to obtain accurate results. Moreover, a conservative approach should be utilized regarding the minimum acceptable recording duration, which ensures valid/reliable HRV estimates are obtained.


2018 ◽  
Vol 40 (02) ◽  
pp. 95-99 ◽  
Author(s):  
Fabiula Novelli ◽  
Jaqueline de Araújo ◽  
Geovane Tolazzi ◽  
Gabriel Tricot ◽  
Gisela Arsa ◽  
...  

AbstractThe aim of this study was to evaluate the reproducibility of the heart rate variability threshold (HRVT) by different HRV indexes and determination criteria. 68 untrained participants, 17 women (24.09±4.91 years old; 21.54±1.97 kg∙m−2) and 51 men (24.52±3.52 years old; 26.51±6.31 kg∙m−2), were evaluated on 2 different days (test and retest). The HRVT was determined during an incremental exercise test using 2 indexes (SD1 and RMSSD) and criteria (HRTV1, first intensity of physical effort with index<3 ms, and HRVT2, first intensity of physical effort, in which the index presents a difference<1 ms between 2 consecutive intensities). There was no significant difference (p<0.05) between the test and retest for any of the variables evaluated. All variables, except for the rate of perceived exertion at HRVT2, presented moderate to high intraclass correlation coefficient (HRVT1: 0.55–0.85 and HRVT2:0.58–0.69). All variables at HRVT1 and the heart rate at HRVT2 showed coefficient of variation ~ 10%. The HRVT, regardless of criteria and HRV index used, showed satisfactory reproducibility. Thus, these criteria can be used to assess clinically autonomic cardiac modulation and aerobic capacity, and to analyze the effect of different interventions.


2010 ◽  
Vol 24 (5) ◽  
pp. 1313-1320 ◽  
Author(s):  
Rodrigo P Simões ◽  
Renata G Mendes ◽  
Viviane Castello ◽  
Heloísa G Machado ◽  
Larissa B Almeida ◽  
...  

2021 ◽  
Vol 11 (5) ◽  
pp. 68
Author(s):  
Jacquelin M. Killian ◽  
Rachel M. Radin ◽  
Cubby L. Gardner ◽  
Lalon Kasuske ◽  
Kylee Bashirelahi ◽  
...  

Using healthy adult participants, seven measures of heart rate variability were obtained simultaneously from four devices in five behavioral conditions. Two devices were ECG-based and two utilized photoplethysmography. The 140 numerical values (measure, condition, device) are presented. The comparative operational reliability of the four devices was assessed, and it was found that the two ECG-base devices were more reliable than the photoplethysmographic devices. The interchangeability of devices was assessed by determining the between-device Limits of Agreement. Intraclass correlation coefficients were determined and used to calculate the standard error of measurement and the Minimal Detectable Difference. The Minimal Detectable Difference, MDD, quantifies the smallest statistically significant change in a measure and is therefore critical when HRV measures are used longitudinally to assess treatment response or disease progression.


2020 ◽  
Vol 44 (11) ◽  
Author(s):  
Angela A. T. Schuurmans ◽  
Peter de Looff ◽  
Karin S. Nijhof ◽  
Catarina Rosada ◽  
Ron H. J. Scholte ◽  
...  

Abstract Wearable monitoring devices are an innovative way to measure heart rate (HR) and heart rate variability (HRV), however, there is still debate about the validity of these wearables. This study aimed to validate the accuracy and predictive value of the Empatica E4 wristband against the VU University Ambulatory Monitoring System (VU-AMS) in a clinical population of traumatized adolescents in residential care. A sample of 345 recordings of both the Empatica E4 wristband and the VU-AMS was derived from a feasibility study that included fifteen participants. They wore both devices during two experimental testing and twelve intervention sessions. We used correlations, cross-correlations, Mann-Whitney tests, difference factors, Bland-Altman plots, and Limits of Agreement to evaluate differences in outcomes between devices. Significant correlations were found between Empatica E4 and VU-AMS recordings for HR, SDNN, RMSSD, and HF recordings. There was a significant difference between the devices for all parameters but HR, although effect sizes were small for SDNN, LF, and HF. For all parameters but RMSSD, testing outcomes of the two devices led to the same conclusions regarding significance. The Empatica E4 wristband provides a new opportunity to measure HRV in an unobtrusive way. Results of this study indicate the potential of the Empatica E4 as a practical and valid tool for research on HR and HRV under non-movement conditions. While more research needs to be conducted, this study could be considered as a first step to support the use of HRV recordings provided by wearables.