Non-destructive determination of 235U, 238U, 232Th and 40K concentrations in various consumed nuts and their implication on radiation dose levels to the human body

2015 ◽  
Vol 307 (2) ◽  
pp. 1065-1068 ◽  
Author(s):  
S. Landsberger ◽  
D. Tamalis ◽  
R. Lara
1983 ◽  
Vol 27 ◽  
Author(s):  
L. Salamanca-Riba ◽  
B.S. Elman ◽  
M.S. Dresselhaus ◽  
T. Venkatesan

ABSTRACTRutherford backscattering spectrometry (RBS) is used to characterize the stoichiometry of graphite intercalation compounds (GIC). Specific application is made to several stages of different donor and acceptor compounds and to commensurate and incommensurate intercalants. A deviation from the theoretical stoichiometry is measured for most of the compounds using this non-destructive method. Within experimental error, the RBS results agree with those obtained from analysis of the (00ℓ) x-ray diffractograms and weight uptake measurements on the same samples.


Author(s):  
Prong Kongsubto ◽  
Sirarat Kongwudthiti

Abstract Organic solderability preservatives (OSPs) pad is one of the pad finishing technologies where Cu pad is coated with a thin film of an organic material to protect Cu from oxidation during storage and many processes in IC manufacturing. Thickness of OSP film is a critical factor that we have to consider and control in order to achieve desirable joint strength. Until now, no non-destructive technique has been proposed to measure OSP thickness on substrate. This paper reports about the development of EDS technique for estimating OSP thickness, starting with determination of the EDS parameter followed by establishing the correlation between C/Cu ratio and OSP thickness and, finally, evaluating the accuracy of the EDS technique for OSP thickness measurement. EDS quantitative analysis was proved that it can be utilized for OSP thickness estimation.


2018 ◽  
Vol 69 (4) ◽  
pp. 875-880
Author(s):  
Oana Roxana Chivu ◽  
Ovidiu Mederle ◽  
Augustin Semenescu ◽  
Ileana Mates ◽  
Claudiu Babis ◽  
...  

The paper describes how to determine the noise in a production hall where there are production machines and equipment. The chosen plant is a production unit where filling of the polyurethane foam tubes is performed. The main activity is the production of professional insulators and wholesale of other products from the same range enumerating the following: wholesale chemical products; production of professional insulators; trade in chemicals and chemical industry. The recommended maximum admissible value for a normal 8h work program is 85 dB (A). The objective is to determine the level of noise in the factory and how it acts as a physical professional risk factor and its effects on the human body. The way in which the proposed objective was achieved was to determine the value of the noise level with the specialized equipment. Following the determinations that will be presented in the following chapters, appropriate protective measures have been taken.


2020 ◽  
Vol 16 ◽  
Author(s):  
Ramazan Akçan ◽  
Halit Canberk Aydogan ◽  
Mahmut Şerif Yıldırım ◽  
Burak Taştekin ◽  
Necdet Sağlam

Background/aim: Use of nanomaterials in the healthcare applications increases in parallel to technological developments. It is frequently utilized in diagnostic procedures, medications and in therapeutic implementations. Nanomaterials take place among key components of medical implants, which might be responsible for certain toxic effects on human health at nano-level. In this review, nanotoxicological effects, toxicity determination of nanobiomaterials used in human body and their effects on human health are discussed. Material and Method: A detailed review of related literature was performed and evaluated as per nanomaterials and medical implants. Results and Conclusion: The nanotoxic effects of the materials applied to human body and the determination of its toxicity are important. Determination of toxicity for each nanomaterial requires a detailed and multifactorial assessment considering the properties of these materials. There are limited studies in the literature regarding the toxic effects of nanomaterials used in medical implants. Although these implants are potentially biocompatible and biodegradable, it is highly important to discuss nanotoxicological characteristics of medical implant.


2019 ◽  
Vol 15 (5) ◽  
pp. 493-499 ◽  
Author(s):  
Francesco Caridi ◽  
Santina Marguccio ◽  
Alberto Belvedere ◽  
Maurizio D`Agostino ◽  
Giovanna Belmusto

Background: In this article a comprehensive study was carried out for the determination of natural radioactivity in animal and vegetable food (meat, fish, milk and derivates, legumes, cereals and derivates, fruit, hortalizas, vegetables, vegetable oils) typical of different feeding regimes, for the age category higher than 17 years. Methods: A total of eighty-five samples of Italian origin, coming from large retailers during the years 2014, 2015 and 2016, were analyzed through HPGe gamma spectrometry. Results: The specific activity of 40K was investigated and its mean value was found to be: (106.3 ± 6.9) Bq/kg for bovine, swine and sheep meat; (116.5 ± 9.7) Bq/kg for fish; (52.9 ± 3.1) Bq/kg for milk and derivates; (271.9 ± 16.7) Bq/kg for legumes; (67.2 ± 4.7) Bq/kg for cereals and derivates; (52.7 ± 4.4) Bq/kg for fruit; (72.9 ± 5.6) Bq/kg for hortalizas; (83.9 ± 6.5) Bq/kg for vegetables; lower than the minimum detectable activity for vegetable oils. For animal food the highest mean 40K activity concentration was found in fish samples; for vegetable food the highest one was detected in legumes. Conclusion: The evaluation of dose levels due to the food ingestion typical of Mediterranean, Vegetarian and Vegan diets was performed. The annual effective dose was found to be 0.16 mSv/y, 0.41 mSv/y and 0.54 mSv/y, respectively.


Metals ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 18
Author(s):  
Rahel Jedamski ◽  
Jérémy Epp

Non-destructive determination of workpiece properties after heat treatment is of great interest in the context of quality control in production but also for prevention of damage in subsequent grinding process. Micromagnetic methods offer good possibilities, but must first be calibrated with reference analyses on known states. This work compares the accuracy and reliability of different calibration methods for non-destructive evaluation of carburizing depth and surface hardness of carburized steel. Linear regression analysis is used in comparison with new methods based on artificial neural networks. The comparison shows a slight advantage of neural network method and potential for further optimization of both approaches. The quality of the results can be influenced, among others, by the number of teaching steps for the neural network, whereas more teaching steps does not always lead to an improvement of accuracy for conditions not included in the initial calibration.


Sign in / Sign up

Export Citation Format

Share Document