scholarly journals Soil chemistry, elemental profiles and elemental distribution in nickel hyperaccumulator species from New Caledonia

2020 ◽  
Vol 457 (1-2) ◽  
pp. 293-320 ◽  
Author(s):  
Vidiro Gei ◽  
Guillaume Echevarria ◽  
Peter D. Erskine ◽  
Sandrine Isnard ◽  
Bruno Fogliani ◽  
...  
Chemoecology ◽  
2016 ◽  
Vol 26 (2) ◽  
pp. 67-82 ◽  
Author(s):  
Antony van der Ent ◽  
Guillaume Echevarria ◽  
Mark Tibbett

2020 ◽  
Vol 194 (1) ◽  
pp. 1-22 ◽  
Author(s):  
Vidiro Gei ◽  
Sandrine Isnard ◽  
Peter D Erskine ◽  
Guillaume Echevarria ◽  
Bruno Fogliani ◽  
...  

Abstract New Caledonia is a global biodiversity hotspot known for its metal hyperaccumulator plants. X-ray fluorescence technology (XRF) has enabled non-destructive and quantitative determination of elemental concentrations in herbarium specimens from the ultramafic flora of the island. Specimens belonging to six major hyperaccumulator families (Cunoniaceae, Phyllanthaceae, Salicaceae, Sapotaceae, Oncothecaceae and Violaceae) and one to four specimens per species of the remaining ultramafic taxa in the herbarium were measured. XRF scanning included a total of c. 11 200 specimens from 35 orders, 96 families, 281 genera and 1484 species (1620 taxa) and covered 88.5% of the ultramafic flora. The study revealed the existence of 99 nickel hyperaccumulator taxa (65 known previously), 74 manganese hyperaccumulator taxa (11 known previously), eight cobalt hyperaccumulator taxa (two known previously) and four zinc hyperaccumulator taxa (none known previously). These results offer new insights into the phylogenetic diversity of hyperaccumulators in New Caledonia. The greatest diversity of nickel hyperaccumulators occur in a few major clades (Malphigiales and Oxalidales) and families (Phyllanthaceae, Salicaceae, Cunoniaceae). In contrast, manganese hyperaccumulation is phylogenetically scattered in the New Caledonian flora.


Plants ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 701
Author(s):  
Yohan Pillon ◽  
Vanessa Hequet

The taxonomy of Argophyllum (Argophyllaceae) in New Caledonia is reviewed here. All names validly published in Argophyllum in this archipelago are discussed and lectotypified when necessary. A new species is described, Argophyllum riparium Pillon and Hequet sp. nov. Argophyllum grunowii and A. ellipticum are both species complexes in which several species previously recognized are included here as well. Seven species are recognized in New Caledonia: A. brevipetalum, A. ellipticum, A. grunowii, A. montanum, A. nitidum, A. riparium and A. vernicosum, all endemic. Leaf nickel content of A. riparium can exceed 1000 μg·g−1, which makes this species a nickel hyperaccumulator. Measurements with a handheld X-Ray Fluorescence (XRF) spectrometer confirmed that this was also the case for all other species from New Caledonia, except A. nitidum. An identification key of New Caledonian species is provided.


2014 ◽  
Vol 14 (1) ◽  
Author(s):  
Jolanta Mesjasz-Przybyłowicz ◽  
Elżbieta Orłowska ◽  
Maria Augustyniak ◽  
Mirosław Nakonieczny ◽  
Monika Tarnawska ◽  
...  

Author(s):  
R.D. Leapman ◽  
C.R. Swyt

The intensity of a characteristic electron energy loss spectroscopy (EELS) image does not, in general, directly reflect the elemental concentration. In fact, the raw core loss image can give a misleading impression of the elemental distribution. This is because the measured core edge signal depends on the amount of plural scattering which can vary significantly from region to region in a sample. Here, we show how the method for quantifying spectra due to Egerton et al. can be extended to maps.


Author(s):  
R. L. Stears

Because of the nature of the bacterial endospore, little work has been done on analyzing their elemental distribution and composition in the intact, living, hydrated state. The majority of the qualitative analysis entailed intensive disruption and processing of the endospores, which effects their cellular integrity and composition.Absorption edge imaging permits elemental analysis of hydrated, unstained specimens at high resolution. By taking advantage of differential absorption of x-ray photons in regions of varying elemental composition, and using a high brightness, tuneable synchrotron source to obtain monochromatic x-rays, contact x-ray micrographs can be made of unfixed, intact endospores that reveal sites of elemental localization. This study presents new data demonstrating the application of x-ray absorption edge imaging to produce elemental information about nitrogen (N) and calcium (Ca) localization using Bacillus thuringiensis as the test specimen.


Author(s):  
N.K.R. Smith ◽  
K.E. Hunter ◽  
P. Mobley ◽  
L.P. Felpel

Electron probe energy dispersive x-ray microanalysis (XRMA) offers a powerful tool for the determination of intracellular elemental content of biological tissue. However, preparation of the tissue specimen , particularly excitable central nervous system (CNS) tissue , for XRMA is rather difficult, as dissection of a sample from the intact organism frequently results in artefacts in elemental distribution. To circumvent the problems inherent in the in vivo preparation, we turned to an in vitro preparation of astrocytes grown in tissue culture. However, preparations of in vitro samples offer a new and unique set of problems. Generally, cultured cells, growing in monolayer, must be harvested by either mechanical or enzymatic procedures, resulting in variable degrees of damage to the cells and compromised intracel1ular elemental distribution. The ultimate objective is to process and analyze unperturbed cells. With the objective of sparing others from some of the same efforts, we are reporting the considerable difficulties we have encountered in attempting to prepare astrocytes for XRMA.Tissue cultures of astrocytes from newborn C57 mice or Sprague Dawley rats were prepared and cultured by standard techniques, usually in T25 flasks, except as noted differently on Cytodex beads or on gelatin. After different preparative procedures, all samples were frozen on brass pins in liquid propane, stored in liquid nitrogen, cryosectioned (0.1 μm), freeze dried, and microanalyzed as previously reported.


Author(s):  
Judith M. Brock ◽  
Max T. Otten

A knowledge of the distribution of chemical elements in a specimen is often highly useful. In materials science specimens features such as grain boundaries and precipitates generally force a certain order on mental distribution, so that a single profile away from the boundary or precipitate gives a full description of all relevant data. No such simplicity can be assumed in life science specimens, where elements can occur various combinations and in different concentrations in tissue. In the latter case a two-dimensional elemental-distribution image is required to describe the material adequately. X-ray mapping provides such of the distribution of elements.The big disadvantage of x-ray mapping hitherto has been one requirement: the transmission electron microscope must have the scanning function. In cases where the STEM functionality – to record scanning images using a variety of STEM detectors – is not used, but only x-ray mapping is intended, a significant investment must still be made in the scanning system: electronics that drive the beam, detectors for generating the scanning images, and monitors for displaying and recording the images.


Author(s):  
Zhifeng Shao ◽  
Ruoya Ho ◽  
Andrew P. Somlyo

Electron energy loss spectroscopy (EELS) has been a powerful tool for high resolution studies of elemental distribution, as well as electronic structure, in thin samples. Its foundation for biological research has been laid out nearly two decades ago, and in the subsequent years it has been subjected to rigorous, but by no means extensive research. In particular, some problems unique to EELS of biological samples, have not been fully resolved. In this article we present a brief summary of recent methodological developments, related to biological applications of EELS, in our laboratory. The main purpose of this work was to maximize the signal to noise ratio (S/N) for trace elemental analysis at a minimum dose, in order to reduce the electron dose and/or time required for the acquisition of high resolution elemental maps of radiation sensitive biological materials.Based on the simple assumption of Poisson distribution of independently scattered electrons, it had been generally assumed that the optimum specimen thickness, at which the S/N is a maximum, must be the total inelastic mean free path of the beam electron in the sample.


Sign in / Sign up

Export Citation Format

Share Document