Frequency-Dependent Electrical Characterization of GO-SiO2 Composites in a Schottky Device

2018 ◽  
Vol 47 (11) ◽  
pp. 6691-6700 ◽  
Author(s):  
Ikram Orak ◽  
Adem Kocyigit ◽  
İbrahim Karteri ◽  
Serhan Uruş
2009 ◽  
Vol 94 (10) ◽  
pp. 102902 ◽  
Author(s):  
É. O’Connor ◽  
S. Monaghan ◽  
R. D. Long ◽  
A. O’Mahony ◽  
I. M. Povey ◽  
...  

2015 ◽  
Vol 821-823 ◽  
pp. 436-439 ◽  
Author(s):  
Razvan Pascu ◽  
Gheorghe Pristavu ◽  
Gheorghe Brezeanu ◽  
Florin Draghici ◽  
Marian Badila ◽  
...  

The electrical behavior and stability of a temperature sensor based on 4H-SiC Schottky diodes using Ni2Si as Schottky contact, are investigated. The ideality factor and the barrier height were found to be strongly dependent on the post-annealing temperature of the Ni contact (which lead to the formation of Ni2Si). A nearly ideal Schottky device, with the barrier height approaching the high value of1.7eV, and a slight temperature dependence, was obtained after an annealing atTA=800°C.This high barrier height proves that Ni2Si is suitable as Schottky contact for temperature sensors, able to reliably operate up to450°C. Sensor sensitivity levels between1.00mV/°Cand2.70 mV/°Chave been achieved.


2011 ◽  
Author(s):  
Isha Gawri ◽  
Mamta Sharma ◽  
S. K. Tripathi ◽  
S. K. Tripathi ◽  
Keya Dharamvir ◽  
...  

2017 ◽  
Vol 113 (02) ◽  
pp. 253
Author(s):  
O. B. Olatinsu ◽  
D. O. Olorode ◽  
M. Josh ◽  
B. Clennell ◽  
L. Esteban

1981 ◽  
Vol 4 ◽  
Author(s):  
T. J. Stultz ◽  
J. F. Gibbons

ABSTRACTStructural and electrical characterization of laser recrystallized LPCVD silicon films on amorphous substrates using a shaped cw laser beam have been performed. In comparing the results to data obtained using a circular beam, it was found that a significant increase in grain size can be achieved and that the surface morphology of the shaped beam recrystallized material was much smoother. It was also found that whereas circular beam recrystallized material has a random grain structure, shaped beam material is highly oriented with a <100> texture. Finally the electrical characteristics of the recrystallized film were very good when measured in directions parallel to the grain boundaries.


2011 ◽  
Vol E94-C (2) ◽  
pp. 157-163 ◽  
Author(s):  
Masakazu MUROYAMA ◽  
Ayako TAJIRI ◽  
Kyoko ICHIDA ◽  
Seiji YOKOKURA ◽  
Kuniaki TANAKA ◽  
...  

Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


Author(s):  
Randal Mulder ◽  
Sam Subramanian ◽  
Tony Chrastecky

Abstract The use of atomic force probe (AFP) analysis in the analysis of semiconductor devices is expanding from its initial purpose of solely characterizing CMOS transistors at the contact level with a parametric analyzer. Other uses found for the AFP include the full electrical characterization of failing SRAM bit cells, current contrast imaging of SOI transistors, measuring surface roughness, the probing of metallization layers to measure leakages, and use with other tools, such as light emission, to quickly localize and identify defects in logic circuits. This paper presents several case studies in regards to these activities and their results. These case studies demonstrate the versatility of the AFP. The needs and demands of the failure analysis environment have quickly expanded its use. These expanded capabilities make the AFP more valuable for the failure analysis community.