scholarly journals The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis

Author(s):  
Valentina Pecoraro ◽  
Davide Petri ◽  
Giorgio Costantino ◽  
Alessandro Squizzato ◽  
Lorenzo Moja ◽  
...  

AbstractNot much is known about how accurate and reproducible different thermometers are at diagnosing patients with suspected fever. The study aims at evaluating which peripheral thermometers are more accurate and reproducible. We searched Medline, Embase, Scopus, WOS, CENTRAL, and Cinahl to perform: (1) diagnostic accuracy meta-analysis (MA) using rectal mercury-in-glass or digital thermometry as reference, and bivariate models for pooling; (2) network MA to estimate differences in mean temperature between devices; (3) Bland–Altman method to estimate 95% coefficient of reproducibility. PROSPERO registration: CRD42020174996. We included 46 studies enrolling more than 12,000 patients. Using 38 °C (100.4 ℉) as cut-off temperature, temporal infrared thermometry had a sensitivity of 0.76 (95% confidence interval, 0.65, 0.84; low certainty) and specificity of 0.96 (0.92, 0.98; moderate certainty); tympanic infrared thermometry had a sensitivity of 0.77 (0.60,  0.88; low certainty) and specificity of 0.98 (0.95, 0.99; moderate certainty). For all the other index devices, it was not possible to pool the estimates. Compared to the rectal mercury-in-glass thermometer, mean temperature differences were not statistically different from zero for temporal or tympanic infrared thermometry; the median coefficient of reproducibility ranged between 0.53 °C [0.95 ℉] for infrared temporal and 1.2 °C [2.16 ℉] for axillary digital thermometry. Several peripheral thermometers proved specific, but not sensitive for diagnosing fever with rectal thermometry as a reference standard, meaning that finding a temperature below 38 °C does not rule out fever. Fixed differences between temperatures together with random error means facing differences between measurements in the order of 2 °C [4.5 ℉]. This study informs practitioners of the limitations associated with different thermometers; peripheral ones are specific but not sensitive.

2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Emily MacLean ◽  
Giorgia Sulis ◽  
Claudia M. Denkinger ◽  
James C. Johnston ◽  
Madhukar Pai ◽  
...  

ABSTRACT Invasive collection methods are often required to obtain samples for the microbiological evaluation of children with presumptive pulmonary tuberculosis (PTB). Nucleic acid amplification testing of easier-to-collect stool samples could be a noninvasive method of diagnosing PTB. We conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of testing stool with the Xpert MTB/RIF assay (“stool Xpert”) for childhood PTB. Four databases were searched for publications from January 2008 to June 2018. Studies assessing the diagnostic accuracy among children of stool Xpert compared to a microbiological reference standard of conventional specimens tested by mycobacterial culture or Xpert were eligible. Bivariate random-effects meta-analyses were performed to calculate pooled sensitivity and specificity of stool Xpert against the reference standard. From 1,589 citations, 9 studies (n = 1,681) were included. Median participant ages ranged from 1.3 to 10.6 years. Protocols for stool processing and testing varied substantially, with differences in reagents and methods of homogenization and filtering. Against the microbiological reference standard, the pooled sensitivity and specificity of stool Xpert were 67% (95% confidence interval [CI], 52 to 79%) and 99% (95% CI, 98 to 99%), respectively. Sensitivity was higher among children with HIV (79% [95% CI, 68 to 87%] versus 60% [95% CI, 44 to 74%] among HIV-uninfected children). Heterogeneity was high. Data were insufficient for subgroup analyses among children under the age of 5 years, the most relevant target population. Stool Xpert could be a noninvasive method of ruling in PTB in children, particularly those with HIV. However, studies focused on children under 5 years of age are needed, and generalizability of the evidence is limited by the lack of standardized stool preparation and testing protocols.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Ali Pormohammad ◽  
Mohammad Javad Nasiri ◽  
Timothy D. McHugh ◽  
Seyed Mohammad Riahi ◽  
Nathan C. Bahr

ABSTRACTThe diagnosis of tuberculous meningitis (TBM) is difficult and poses a significant challenge to physicians worldwide. Recently, nucleic acid amplification (NAA) tests have shown promise for the diagnosis of TBM, although their performance has been variable. We undertook a systematic review and meta-analysis to evaluate the diagnostic accuracy of NAA tests with cerebrospinal fluid (CSF) samples against that of culture as the reference standard or a combined reference standard (CRS) for TBM. We searched the Embase, PubMed, Web of Science, and Cochrane Library databases for the relevant records. The QUADAS-2 tool was used to assess the quality of the studies. Diagnostic accuracy measures (i.e., sensitivity and specificity) were pooled with a random-effects model. All statistical analyses were performed with STATA (version 14 IC; Stata Corporation, College Station, TX, USA), Meta-DiSc (version 1.4 for Windows; Cochrane Colloquium, Barcelona, Spain), and RevMan (version 5.3; The Nordic Cochrane Centre, the Cochrane Collaboration, Copenhagen, Denmark) software. Sixty-three studies comprising 1,381 cases of confirmed TBM and 5,712 non-TBM controls were included in the final analysis. These 63 studies were divided into two groups comprising 71 data sets (43 in-house tests and 28 commercial tests) that used culture as the reference standard and 24 data sets (21 in-house tests and 3 commercial tests) that used a CRS. Studies which used a culture reference standard had better pooled summary estimates than studies which used CRS. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the NAA tests against culture were 82% (95% confidence interval [CI], 75 to 87%), 99% (95% CI, 98 to 99%), 58.6 (95% CI, 35.3 to 97.3), and 0.19 (95% CI, 0.14 to 0.25), respectively. The pooled sensitivity, specificity, PLR, and NLR of NAA tests against CRS were 68% (95% CI, 41 to 87%), 98% (95% CI, 95 to 99%), 36.5 (95% CI, 15.6 to 85.3), and 0.32 (95% CI, 0.15 to 0.70), respectively. The analysis has demonstrated that the diagnostic accuracy of NAA tests is currently insufficient for them to replace culture as a lone diagnostic test. NAA tests may be used in combination with culture due to the advantage of time to result and in scenarios where culture tests are not feasible. Further work to improve NAA tests would benefit from the availability of standardized reference standards and improvements to the methodology.


2016 ◽  
Vol 17 (1) ◽  
pp. 3-8 ◽  
Author(s):  
S. Buczinski ◽  
G. Fecteau ◽  
M. Chigerwe ◽  
J. M. Vandeweerd

AbstractCalves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.


2015 ◽  
Vol 53 (12) ◽  
pp. 3738-3749 ◽  
Author(s):  
Caroline Chartrand ◽  
Nicolas Tremblay ◽  
Christian Renaud ◽  
Jesse Papenburg

Respiratory syncytial virus (RSV) rapid antigen detection tests (RADT) are extensively used in clinical laboratories. We performed a systematic review and meta-analysis to evaluate the accuracy of RADTs for diagnosis of RSV infection and to determine factors associated with accuracy estimates. We searched EMBASE and PubMed for diagnostic-accuracy studies of commercialized RSV RADTs. Studies reporting sensitivity and specificity data compared to a reference standard (reverse transcriptase PCR [RT-PCR], immunofluorescence, or viral culture) were considered. Two reviewers independently extracted data on study characteristics, diagnostic-accuracy estimates, and study quality. Accuracy estimates were pooled using bivariate random-effects regression models. Heterogeneity was investigated with prespecified subgroup analyses. Seventy-one articles met inclusion criteria. Overall, RSV RADT pooled sensitivity and specificity were 80% (95% confidence interval [CI], 76% to 83%) and 97% (95% CI, 96% to 98%), respectively. Positive- and negative-likelihood ratios were 25.5 (95% CI, 18.3 to 35.5) and 0.21 (95% CI, 0.18 to 0.24), respectively. Sensitivity was higher in children (81% [95% CI, 78%, 84%]) than in adults (29% [95% CI, 11% to 48%]). Because of this disparity, further subgroup analyses were restricted to pediatric data (63 studies). Test sensitivity was poorest using RT-PCR as a reference standard and highest using immunofluorescence (74% versus 88%;P< 0.001). Industry-sponsored studies reported significantly higher sensitivity (87% versus 78%;P= 0.01). Our results suggest that the poor sensitivity of RSV RADTs in adults may preclude their use in this population. Furthermore, industry-sponsored studies and those that did not use RT-PCR as a reference standard likely overestimated test sensitivity.


2020 ◽  
Vol 27 (8) ◽  
Author(s):  
Nishant Aggarwal ◽  
Mohil Garg ◽  
Vignesh Dwarakanathan ◽  
Nitesh Gautam ◽  
Swasthi S Kumar ◽  
...  

Abstract Infrared thermal screening, via the use of handheld non-contact infrared thermometers (NCITs) and thermal scanners, has been widely implemented all over the world. We performed a systematic review and meta-analysis to investigate its diagnostic accuracy for the detection of fever. We searched PubMed, Embase, the Cochrane Library, medRxiv, bioRxiv, ClinicalTrials.gov, COVID-19 Open Research Dataset, COVID-19 research database, Epistemonikos, EPPI-Centre, World Health Organization International Clinical Trials Registry Platform, Scopus and Web of Science databases for studies where a non-contact infrared device was used to detect fever against a reference standard of conventional thermometers. Forest plots and Hierarchical Summary Receiver Operating Characteristics curves were used to describe the pooled summary estimates of sensitivity, specificity and diagnostic odds ratio. From a total of 1063 results, 30 studies were included in the qualitative synthesis, of which 19 were included in the meta-analysis. The pooled sensitivity and specificity were 0.808 (95%CI 0.656–0.903) and 0.920 (95%CI 0.769–0.975), respectively, for the NCITs (using forehead as the site of measurement), and 0.818 (95%CI 0.758–0.866) and 0.923 (95%CI 0.823–0.969), respectively, for thermal scanners. The sensitivity of NCITs increased on use of rectal temperature as the reference. The sensitivity of thermal scanners decreased in a disease outbreak/pandemic setting. Changes approaching statistical significance were also observed on the exclusion of neonates from the analysis. Thermal screening had a low positive predictive value, especially at the initial stage of an outbreak, whereas the negative predictive value (NPV) continued to be high even at later stages. Thermal screening has reasonable diagnostic accuracy in the detection of fever, although it may vary with changes in subject characteristics, setting, index test and the reference standard used. Thermal screening has a good NPV even during a pandemic. The policymakers must take into consideration the factors surrounding the screening strategy while forming ad-hoc guidelines.


2013 ◽  
Vol 3 (1) ◽  
pp. 18-27 ◽  
Author(s):  
Tatiana Raskovalova ◽  
Raphael Twerenbold ◽  
Paul O Collinson ◽  
Till Keller ◽  
Hélène Bouvaist ◽  
...  

Aims: This systematic review aimed to investigate the diagnostic accuracy of combined cardiac troponin (cTn) and copeptin assessment in comparison to cTn alone for early rule-out of acute myocardial infarction (AMI). Methods: Primary studies were eligible if they evaluated diagnostic accuracy for cTn with and without copeptin in patients with symptoms suggestive of AMI. AMI was defined according to the universal definition, using detection of cTn as a marker for myocardial necrosis. Eligible studies were identified by searching electronic databases (Medline, EMBASE, Science Citation Index Expanded, CINAHL, Pascal, and Cochrane) from inception to March 2013, reviewing conference proceedings and contacting field experts and the copeptin manufacturer. Results: In 15 studies totalling 8740 patients (prevalence of AMI 16%), adding copeptin improved the sensitivity of cTn assays (from 0.87 to 0.96, p=0.003) at the expense of lower specificity (from 0.84 to 0.56, p<0.001). In 12 studies providing data for 6988 patients without ST-segment elevation, the summary sensitivity and specificity estimates were 0.95 (95% CI 0.89 to 0.98) and 0.57 (95% CI 0.49 to 0.65) for the combined assessment of cTn and copeptin. When a high-sensitivity cTnT assay was used in combination with copeptin, the summary sensitivity and specificity estimates were 0.98 (95% CI 0.96 to 1.00) and 0.50 (95% CI 0.42 to 0.58). Conclusion: Despite substantial between-study heterogeneity, this meta-analysis demonstrates that copeptin significantly improves baseline cTn sensitivity. Management studies are needed to establish the effectiveness and safety of measuring copeptin in combination with high-sensitivity cTnT for early rule-out of AMI without serial testing.


2012 ◽  
Vol 59 (6) ◽  
pp. 517-520.e4 ◽  
Author(s):  
Balwinder Singh ◽  
Ajay K. Parsaik ◽  
Dipti Agarwal ◽  
Alok Surana ◽  
Soniya S. Mascarenhas ◽  
...  

BMJ Open ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. e040765
Author(s):  
Aoife Leahy ◽  
Margaret O’Connor ◽  
Jennifer Condon ◽  
Sarah Heywood ◽  
Elaine Shanahan ◽  
...  

IntroductionFrailty is a common condition affecting older adults and is associated with increased mortality and adverse outcomes. Identification of older adults at risk of adverse outcomes is central to subsequent resource planning and targeted interventions. This systematic review and meta-analysis will examine the: (1) diagnostic accuracy of the Clinical Frailty Scale (CFS) in identifying hospitalised adults ≥65 years with frailty and a medical diagnosis compared with the reference standard Frailty Index or Frailty Phenotype and (2) predictive value of the CFS in determining those at increased risk of subsequent adverse outcomes.Methods and analysisWe will include cross-sectional, retrospective and prospective cohort studies, and randomised controlled trials that assess either the diagnostic accuracy of the CFS when compared with the reference standard Frailty Index/Frailty Phenotype or the predictive validity of the CFS to predict subsequent adverse outcomes in hospitalised adults over 65 years with medical complaints. Adverse outcomes include falls, functional decline, unplanned Emergency Department attendance, emergency rehospitalisation, nursing home admission or death. A systematic search will be conducted in Embase, AMED, MEDLINE (Ebsco, Ovid, Pubmed), CINAHL, PsycINFO, Cochrane Library. Studies will be limited to those published from 2005 to 30 October 2019. Two independent reviewers will screen all titles and abstracts to identify relevant studies. The methodological quality of studies will be independently assessed using the Quality Assessment of Diagnostic Accuracy Studies-2. A CFS score of >4 will be used to identify frailty. We will construct 2×2 tables and determine true positives, true negatives, false positives and false negatives for each study when compared with the reference standard and for each adverse outcome. A bivariate random effects model will be applied to generate pooled summary estimates of sensitivity and specificity.Ethics and disseminationEthical approval is not required for this systematic review. We will disseminate our findings through a peer-reviewed journal.


CJEM ◽  
2019 ◽  
Vol 21 (6) ◽  
pp. 727-738 ◽  
Author(s):  
Stuart Netherton ◽  
Velimir Milenkovic ◽  
Mark Taylor ◽  
Philip J. Davis

ABSTRACTObjectivesPerforming an extended Focused Assessment with Sonography in Trauma (eFAST) exam is common practice in the initial assessment of trauma patients. The objective of this study was to systematically review the published literature on diagnostic accuracy of all components of the eFAST exam.MethodsWe searched Medline and Embase from inception through October 2018, for diagnostic studies examining the sensitivity and specificity of the eFAST exam. After removal of duplicates, 767 records remained for screening, of which 119 underwent full text review. Meta-DiSc™ software was used to create pooled sensitivities and specificities for included studies. Study quality was assessed using the Quality in Prognostic Studies (QUADAS-2) tool.ResultsSeventy-five studies representing 24,350 patients satisfied our selection criteria. Studies were published between 1989 and 2017. Pooled sensitivities and specificities were calculated for the detection of pneumothorax (69% and 99% respectively), pericardial effusion (91% and 94% respectively), and intra-abdominal free fluid (74% and 98% respectively). Sub-group analysis was completed for detection of intra-abdominal free fluid in hypotensive (sensitivity 74% and specificity 95%), adult normotensive (sensitivity 76% and specificity 98%) and pediatric patients (sensitivity 71% and specificity 95%).ConclusionsOur systematic review and meta-analysis suggests that e-FAST is a useful bedside tool for ruling in pneumothorax, pericardial effusion, and intra-abdominal free fluid in the trauma setting. Its usefulness as a rule-out tool is not supported by these results.


Sign in / Sign up

Export Citation Format

Share Document