Characterization and Classification of Extra Virgin Olive Oil from Five Less Well-Known Greek Olive Cultivars

2016 ◽  
Vol 93 (6) ◽  
pp. 837-848 ◽  
Author(s):  
Ioanna Kosma ◽  
Maria Vavoura ◽  
Stavros Kontakos ◽  
Ioannis Karabagias ◽  
Michael Kontominas ◽  
...  
2014 ◽  
Vol 69 (1) ◽  
Author(s):  
Abdul Rohman ◽  
Intan Gupitasari ◽  
Purwanto Purwanto ◽  
Kuwat Triyana ◽  
Arieff Salleh Rosman ◽  
...  

The presence of lard (LD) in cosmetics products is a serious matter for certain religion, like Islam. The Muslim community is not allowed to use cosmetics products containing pig derivatives such as LD. Therefore, analysis of LD in cosmetics products is highly needed. The present study highlighted the employment of Fourier transform infrared (FTIR) spectroscopy in combination with chemometrics of multivariate calibration and principle component analysis (PCA) for quantitative analysis and classification of LD in the binary mixture with extra virgin olive oil (EVOO) as oil base in cream formulations for halal authentication. The lipid component in cream was extracted using liquid-liquid extraction using hexane as extracting solvent, and the lipid obtained was subjected to FTIR spectra measurement, using horizontal attenuated total reflectance as sampling technique. The result showed that FTIR spectroscopy in combination with partial least squares can be used to quantify the levels of LD in the mixture with EVOO in cosmetics creams using the combined frequency regions of 1785-702 cm-1 and 3020-2808 cm-1. PCA using absorbance intensities at 1200 – 1000 cm-1 as variables has been successfully used for the classification of cream with and without LD in the formulation. The developed method is rapid and not involving the excessive sample preparation.


2015 ◽  
Vol 7 (20) ◽  
pp. 8839-8846 ◽  
Author(s):  
Karla Danielle Tavares de Melo Milanez ◽  
Márcio José Coelho Pontes

This work proposes a new methodology based on digital images and supervised pattern recognition methods for the classification of extra virgin olive oil (EVOO) samples with respect to brand (A, B and C) and verification of adulteration with soybean oil.


2020 ◽  
Vol 159 ◽  
pp. 105544
Author(s):  
Flavia T. Borghi ◽  
Priscilla C. Santos ◽  
Francine D. Santos ◽  
Márcia H.C. Nascimento ◽  
Thayná Corrêa ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Cinzia Montemurro ◽  
Monica Marilena Miazzi ◽  
Antonella Pasqualone ◽  
Valentina Fanelli ◽  
Wilma Sabetta ◽  
...  

The aim of the research was to verify the applicability of microsatellite (SSR) markers in High Resolution Melting (HRM) analysis for the identification of the olive cultivars used in the “Terra di Bari” PDO extra virgin olive oil. A panel of nine cultivars, widespread in Apulia region, was tested with seventeen SSR primer pairs and the PCR products were at first analysed with a Genetic Analyzer automatic sequencer. An identification key was obtained for the nine cultivars, which showed an unambiguous discrimination among the varieties constituting the “Terra di Bari” PDO extra virgin olive oil: Cima di Bitonto, Coratina, and Ogliarola. Subsequently, an SSR based method was set up with the DCA18 marker, coupled with HRM analysis for the distinction of the Terra di Bari olive oil from non-Terra di Bari olive oil using different mixtures. Thus, this analysis enabled the distinction and identification of the PDO mixtures. Hence, this assay provided a flexible, cost-effective, and closed-tube microsatellite genotyping method, well suited to varietal identification and authentication analysis in olive oil.


Foods ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 2823
Author(s):  
Pujun Xie ◽  
Lorenzo Cecchi ◽  
Maria Bellumori ◽  
Diletta Balli ◽  
Lisa Giovannelli ◽  
...  

Phenolic and triterpenoid compounds of the olive tree are recognized as having a key role in health promotion, thanks to their multiple protective actions in humans. To expand the source of these bioactive compounds, the phenolic and triterpenoid profiles of leaf, branch, destoned fruit, destoned pomace, shell, seed, and extra virgin olive oil from the Frantoio, Leccino, and Moraiolo olive cultivars were simultaneously characterized by HPLC-DAD-MS. Overall, 43 molecules were quantitated and expressed on the obtained dry extracts. Oleuropein was mainly concentrated in branches (82.72 g/kg), fruits (55.79 g/kg), leaves (36.71 g/kg), and shells (1.26 g/kg), verbascoside (4.88 g/kg) in pomace, and nüzhenide 11-methyl oleoside (90.91 g/kg) in seeds. Among triterpenoids, which were absent in shells, the highest amount of oleanolic acid was found in olive leaves (11.88 g/kg). HCT-116 colorectal cells were chosen to assess the cytotoxicity of the dry extract, using the phytocomplex from Frantoio, which was the richest in phenols and triterpenoids. The IC50 was also determined for 13 pure molecules (phenols and terpenoids) detected in the extracts. The greatest inhibition on the cell’s proliferation was induced by the branch dry extract (IC50 88.25 μg/mL) and by ursolic acid (IC50 24 μM). A dose-dependent relationship was observed for the tested extracts.


Measurement ◽  
2016 ◽  
Vol 78 ◽  
pp. 366-372 ◽  
Author(s):  
Maurizio Caciotta ◽  
Sabino Giarnetti ◽  
Fabio Leccese ◽  
Barbara Orioni ◽  
Marco Oreggia ◽  
...  

2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Abdul Rohman ◽  
Y. B. Che Man

Commercially, extra virgin olive oil (EVOO) is subjected to be adulterated with low-price oils having similar color to EVOO. Fourier transform infrared (FTIR) spectroscopy combined with chemometrics has been successfully used for classification and quantification of corn (CO) and sunflower oils (SFOs) in EVOO sets. The combined frequency regions of 3027–3000, 1076–860, and 790–698 cm-1were used for classification and quantification of CO in EVOO; meanwhile, SFO was analyzed using frequency regions of 3025–3000 and 1400–985 cm-1. Discriminant analysis can make classification of pure EVOO and EVOO adulterated with CO and SFO with no misclassification reported. The presence of CO in EVOO was determined with the aid of partial least square calibration using FTIR normal spectra. The calibration and validation errors obtained in CO's quantification are 0.404 and 1.13%, respectively. Meanwhile, the first derivative FTIR spectra and PLS calibration model were preferred for quantification of SFO in EVOO with high coefficient of determination (R2) and low errors, either in calibration or in validation sample sets.


2015 ◽  
Vol 7 (6) ◽  
pp. 2180-2189 ◽  
Author(s):  
Hery Mitsutake ◽  
Lucas C. Gontijo ◽  
Felipe B. de Santana ◽  
Eloiza Guimarães ◽  
Lilian Lúcia da Rocha ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document