Preoperative international normalised ratio (INR) and bleeding during open-heart procedure

2004 ◽  
Vol 20 (3) ◽  
pp. 132-134
Author(s):  
Pawan Kumar ◽  
Raghvendra Chikkatur ◽  
Pranav Kandhachar ◽  
Rajesh Parida ◽  
Vinod Ahuja ◽  
...  
2004 ◽  
Vol 20 (1) ◽  
pp. 42-43
Author(s):  
P Kumar ◽  
SK Pranav ◽  
C Raghavendra ◽  
R Parida ◽  
V Ahuja ◽  
...  

1978 ◽  
Vol 39 (02) ◽  
pp. 474-487 ◽  
Author(s):  
E R Cole ◽  
F Bachmann ◽  
C A Curry ◽  
D Roby

SummaryA prospective study in 13 patients undergoing open-heart surgery with extracorporeal circulation revealed a marked decrease of the mean one-stage prothrombin time activity from 88% to 54% (p <0.005) but lesser decreases of factors I, II, V, VII and X. This apparent discrepancy was due to the appearance of an inhibitor of the extrinsic coagulation system, termed PEC (Protein after Extracorporeal Circulation). The mean plasma PEC level rose from 0.05 U/ml pre-surgery to 0.65 U/ml post-surgery (p <0.0005), and was accompanied by the appearance of additional proteins as evidenced by disc polyacrylamide gel electrophoresis of plasma fractions (p <0.0005). The observed increases of PEC, appearance of abnormal protein bands and concomitant increases of LDH and SGOT suggest that the release of an inhibitor of the coagulation system (similar or identical to PIVKA) may be due to hypoxic liver damage during extracorporeal circulation.


1994 ◽  
Vol 72 (03) ◽  
pp. 426-429 ◽  
Author(s):  
S Kitchen ◽  
I D Walker ◽  
T A L Woods ◽  
F E Preston

SummaryWhen the International Normalised Ratio (INR) is used for control of oral anticoagulant therapy the same result should be obtained irrespective of the laboratory reagent used. However, in the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation INRs determined using different reagents have been significantly different.For 18 NEQAS samples Manchester Reagent (MR) was associated with significantly lower INRs than those obtained using Diagen Activated (DA, p = 0.0004) or Instrumentation Laboratory PT-Fib HS (IL, p = 0.0001). Mean INRs for this group were 3.15, 3.61, and 3.65 for MR, DA, and IL respectively. For 61 fresh samples from warfarin-ised patients with INRs of greater than 3.0 the relationship between thromboplastins in respect of INR was similar to that observed for NEQAS data. Thus INRs obtained with MR were significantly lower than with DA or IL (p <0.0001). Mean INRs for this group were 4.01, 4.40, and 4.59 for MR, DA, and IL respectively.We conclude that the differences between INRs measured with the thromboplastins studied here are sufficiently great to influence patient management through warfarin dosage schedules, particularly in the upper therapeutic range of INR. There is clearly a need to address the issues responsible for the observed discrepancies.


1994 ◽  
Vol 72 (01) ◽  
pp. 084-088 ◽  
Author(s):  
E M Duncan ◽  
C R Casey ◽  
B M Duncan ◽  
J V Lloyd

SummaryThe aim of this study was to determine whether the concentration of trisodium citrate used to anticoagulate blood has an effect on the INR of the sample and the ISI of the thromboplastin. Five thromboplastins including and Australian reference material were used to measure the prothrombin time of normal and patient samples collected into two concentrations of trisodium citrate - 109 mM and 129 mM. There was no effect of citrate concentration on the INRs determined with the reference material. However for the other four thromboplastins there was a significant difference between INRs for the two citrate groups. The prothrombin times of the samples collected into 129 mM were longer than those collected into 109 mM. This difference was only slight in normal plasma but more marked in patients receiving oral anticoagulants, causing the INRs for patient plasmas collected into 129 mM citrate to be higher then the corresponding samples collected into 109 mM citrate.From orthogonal regression of log prothrombin times by the reference method against each thromboplastin, we found that the ISI for each thromboplastin was approximately 10% lower when determined with samples collected into 129 mM citrate than with samples collected into 109 mM. These results suggest that the concentration of trisodium citrate used for collection of blood samples can affect the calculation of the INR and the calibration of the ISI of thromboplastin. This was found both for commercial thromboplastins prepared by tissue extraction and for a recombinant tissue factor.


1967 ◽  
Vol 18 (03/04) ◽  
pp. 634-646 ◽  
Author(s):  
N Thurnherr

SummaryBlood clotting investigations have been executed in 25 patients who have undergone open heart surgery with extracorporeal circulation. A description of alterations in the activity of blood clotting factors, the fibrinolytic system, prothrombin consumption and platelets during several phases of the operation is given.


1985 ◽  
Vol 54 (02) ◽  
pp. 515-517 ◽  
Author(s):  
E A Loeliger ◽  
L Poller ◽  
M Samama ◽  
J M Thomson ◽  
A M H P Van den Besselaar ◽  
...  

SummaryOne of the reasons why oral anticoagulants fell into disrepute is the absence of internationally accepted standardised procedures for controlling the level of anticoagulatiori. This deplorable situation resulted in over- and under-coagulation and uncertainty in the therapeutic range. International conformity can now be obtained by using an International Normalised Ratio (INR) which is derived from the individual result obtained in a given plasma sample and the International Sensitivity Index (ISI) of the tissue thromboplastin reagent used. Any thromboplastin reagent can be calibrated against an international primary or secondary W.H.O. reference preparation, so as to obtain its International Sensitivity Index. The new system of reporting the level of anticoagulation was designed and can only safely be applied in patients taking oral anticoagulants.


Sign in / Sign up

Export Citation Format

Share Document