Comparing the performance of the conventional and fixed‐bed membrane bioreactors for treating municipal wastewater

Author(s):  
Hamidreza Khastoo ◽  
Amir Hessam Hassani ◽  
Roya Mafigholami ◽  
Rouhallah Mahmoudkhani
2015 ◽  
Vol 4 (0) ◽  
pp. 9781780402925-9781780402925
Author(s):  
H. van der Roest ◽  
D. Lawrence ◽  
A. van Bentem

2005 ◽  
Vol 51 (6-7) ◽  
pp. 1-8 ◽  
Author(s):  
B. Lesjean ◽  
S. Rosenberger ◽  
C. Laabs ◽  
M. Jekel ◽  
R. Gnirss ◽  
...  

Two similar membrane bioreactors of 2 m3 each were operated in parallel over two years under the same operational conditions, fed with the same municipal wastewater. The only process and operational difference between both pilot plants was the position of the denitrification zone (pre-denitrification in pilot 1 and post-denitrification in pilot 2). Despite parallel operation, the two MBRs exhibited different fouling rates and decreases in permeability. These differences could not be accounted for by MLSS concentrations, loading rates, or filtration flux. In a one-year investigation, soluble and colloidal organic material in the activated sludge of both MBR was regularly analysed by spectrophotometric and Size Exclusion Chromatography (SEC) methods. The larger organic molecules present in the sludge water phase (i.e. polysaccharides, proteins and organic colloids) originating from microbial activity (extracellular polymeric substances) were found to impact on the fouling and to explain the difference in membrane performance between the two MBR units. In both pilot plants, a linear relationship could be clearly demonstrated between the fouling rate of the membrane and the concentration of polysaccharides in the sludge water phase during a 5 month operational period at an SRT of 8 days.


2012 ◽  
Vol 122 ◽  
pp. 2-10 ◽  
Author(s):  
Jeremy T. Kraemer ◽  
Adrienne L. Menniti ◽  
Zeynep K. Erdal ◽  
Timothy A. Constantine ◽  
Bruce R. Johnson ◽  
...  

Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 231
Author(s):  
Yi Ding ◽  
Zhansheng Guo ◽  
Zhenlin Liang ◽  
Xuguang Hou ◽  
Zhipeng Li ◽  
...  

In this study, the characteristics of activated sludge flocs were investigated and their effects on the evolution of membrane fouling were considered in the anaerobic membrane bioreactors (AnMBR), which were operated at 25 and 35 °C for municipal wastewater treatment. It was found that the membrane fouling rate of the AnMBR at 25 °C was more severe than that at 35 °C. The membrane fouling trends were not consistent with the change in the concentration of soluble microbial product (SMP). The larger amount of SMP in the AnMBR at 35 °C did not induce more severe membrane fouling than that in the AnMBR at 25 °C. However, the polysaccharide and protein concentration of extracellular polymeric substance (EPS) was higher in the AnMBR at 25 °C in comparison with that in the AnMBR at 35 °C, and the protein/polysaccharide ratio of the EPS in the AnMBR at 25 °C was higher in contrast to that in the AnMBR at 35 °C. Meanwhile, the fouling tendencies measured for the AnMBRs could be related to the characteristics of loosely bound EPS and tightly bound EPS. The analysis of the activated sludge flocs characteristics indicated that a smaller sludge particle size and more fine flocs were observed at the AnMBR with 25 °C. Therefore, the membrane fouling potential in the AnMBR could be explained by the characteristics of activated sludge flocs.


2001 ◽  
Vol 44 (1) ◽  
pp. 105-112 ◽  
Author(s):  
M. Burde ◽  
F. Rolf ◽  
F. Grabowski

The absence of large rivers with rather high niveau of self purifying effect in parts of east Germany leads to a discharging of the effluent of wastewater treatment plants into the groundwater in many cases. One useful consequence is the idea of realisation of decentralised measures and concepts in urban water resources management concerning municipal wastewater as well as rainfall, precipitation. At the same time, only the upper soil zone - a few decimetres - is water - saturated and thus discharge effective, even when extreme rainfall takes place. Underneath, however, there generally exists an unsaturated soil zone, which is up to now a rather unexplored retardation element of the hydrologic- and substrate-cycle. Nutrient removal in small wastewater treatment plants that are emptying into ground waters is often beneficial. The presented studies optimised an inexpensive method of subsequent enhanced wastewater treatment. The developed reactor is similar to a concentrated subsoil passage. The fixed bed reactor is divided in two sections to achieve aerobic and anoxic conditions for nitrification/denitrification processes. To enhance phosphorus removal, ferrous particles are put into the aerobic zone. Two series of column tests were carried out and a technical pilot plant was built to verify the efficiency of the process. The results show that this method can be implemented successfully.


2012 ◽  
Vol 65 (6) ◽  
pp. 1109-1115 ◽  
Author(s):  
L. Rodríguez-Hernández ◽  
A. L. Esteban-García ◽  
A. Lobo ◽  
J. Temprano ◽  
C. Álvaro ◽  
...  

A new hybrid membrane bioreactor (HMBR) has been developed to obtain a compact module, with a small footprint and low requirement for aeration. The aim of this research was to assess its performance. The system consists of a single vertical reactor with a filtration membrane unit and, above this, a sponge fixed bed as support medium. The aeration system is located under the membrane unit, allowing for membrane cleaning, oxygenation, biofilm thickness control and bulk liquid mixing. Operated under continuous aeration, a bench-scale reactor (70 L) was fed with pre-treated, raw (unsettled) municipal wastewater. BOD5 and suspended solids removal efficiencies (96 and 99% respectively) were comparable to those obtained with other membrane bioreactors (MBRs). Total nitrogen removal efficiencies of 80% were achieved, which is better than those obtained in other HMBRs and similar to the values reached using more complex MBRs with extra anoxic tanks, intermittent aeration or internal deflectors.


1990 ◽  
Vol 22 (1-2) ◽  
pp. 475-482 ◽  
Author(s):  
C. Collivignarelli ◽  
G. Urbini ◽  
A. Farneti ◽  
A. Bassetti ◽  
U. Barbaresi

The results of pilot experiments on municipal wastewater treatment using advanced processes are described. The most important aims of this research were to achieve reductions in energy consumption, environmental impact, quantity of stabilized sludge produced, and area necessary for plant construction. The pilot plant, which was constructed in the environs of the Senigallia (AN, Italy) municipal wastewater treatment plant, had a capacity of 500 to 2500 population equivalents (p.e.). In the most attractive system, municipal wastewaters with a low organic concentration were first treated in an upflow anaerobic sludge blanket (UASB) bioreactor with a capacity of 336 m3. Part of the effluent from this process was then conveyed to an anoxic biological fluidized bed (with a volume of 8 m3 filled with 3 m3 of quartzite sand) for pre-denitrification, and then to an aerobic fixed bed (with random plastic media and a volume of 8m3) for nitrification. It was also possible to treat the municipal wastewaters using the anaerobic fluidized bed directly, after microscreening or primary sedimentation. The research undertaken was intended to verify the reliability of these processes at ambient temperatures and with variable wastewater concentrations. The preliminary results obtained for COD, BOD, and N removal from municipal wastewaters indicate that this system is quite an attractive treatment alternative, mainly due to its low sludge production and energy consumption. These results will enable accurate design criteria to be identified for the construction of more economic treatment plants on a larger scale.


Sign in / Sign up

Export Citation Format

Share Document