CJ89-45. The on-line measurement technique for the bulk modulus of hydraulic fluid

1990 ◽  
Vol 32 (2) ◽  
pp. 161
1993 ◽  
Vol 115 (1) ◽  
pp. 85-92 ◽  
Author(s):  
J. Ni ◽  
S. M. Wu

A hybrid on-line and off-line measurement technique is developed for machine volumetric error compensation based on a multiple-degree-of-freedom laser optical system. When implemented on a 3-axis machine up to 15 geometric error components can be measured simultaneously on-line and the remaining 6 components need to be calibrated off-line. Since the on-line measurement systems use different metrology bases, a modified volumetric error model is derived for a milling machine by considering the measurement features of the multiple-degree-of-freedom system. Through experimental tests, it was found that the discrepancy between the identified errors and the actual errors was less than 4 μm out of a maximum range of 20 μm.


1996 ◽  
Vol 27 ◽  
pp. S295-S296
Author(s):  
I.L. Tuinman ◽  
J. Veenstra ◽  
J.C.M. Marijnissen ◽  
B. Scarlett ◽  
J. Schoonman

Author(s):  
John F. Mansfield ◽  
Douglas C. Crawford

A method has been developed that allows on-line measurement of the thickness of crystalline materials in the analytical electron microscope. Two-beam convergent beam electron diffraction (CBED) patterns are digitized from a JEOL 2000FX electron microscope into an Apple Macintosh II microcomputer via a Gatan #673 CCD Video Camera and an Imaging Systems Technology Video 1000 frame-capture board. It is necessary to know the lattice parameters of the sample since measurements are made of the spacing of the diffraction discs in order to calibrate the pattern. The sample thickness is calculated from measurements of the spacings of the fringes that are seen in the diffraction discs. This technique was pioneered by Kelly et al, who used the two-beam dynamic theory of MacGillavry relate the deviation parameter (Si) of the ith fringe from the exact Bragg condition to the specimen thickness (t) with the equation:Where ξg, is the extinction distance for that reflection and ni is an integer.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 531-538 ◽  
Author(s):  
B. Teichgräber

A nitrification/denitrification process was applied to reject water treatment from sludge dewatering at Bottrop central sludge treatment facilities of the Emschergenossenschaft. On-line monitoring of influent and effluent turbidity, closed loop control of DO and pH, and on-line monitoring of nitrogen compounds were combined to a three level control pattern. Though on-line measurement of substrate and product showed substantial response time it could be used to operate nitrification/denitrification within process boundaries.


Author(s):  
Qiwen Jin ◽  
Xijiong Chen ◽  
Pei Li ◽  
Yonggang Zhou ◽  
Yingchun Wu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document