Postural muscle atrophy prevention and recovery and bone remodelling through high frequency proprioception for astronauts

2009 ◽  
Vol 65 (5-6) ◽  
pp. 813-819 ◽  
Author(s):  
Dario Riva ◽  
Franco Rossitto ◽  
Luciano Battocchio
Author(s):  
Adiba Ali ◽  
Yi-Xian Qin

Osteoporosis, induced by aging and long-term disuse, often occurs together with muscle loss. Musculoskeletal disuse causes severe physiologic changes and it has been proposed the synergistic effects of muscle function and bone adaptation. Bone fluid flow has been shown to be induced during mechanical loading, and is proposed to be a critical mediator of bone adaptation. The skeletal muscle may serve as a muscle pump that may mediate bone mechanotransduction via modulation of intramedullary pressure. Thus, muscular stimulation is proposed to be used to simultaneously treat both muscle and bone loss, but the optimal parameters required for such treatment is unclear. Studies have separately investigated the optimal signal parameters for bone or muscle. Insertion of recovery periods during high frequency stimulations have shown potential to reduce muscle atrophy by minimizing fatigue and mimicking physiologic contractions, and demonstrated enhancement of bone remodeling. Our preliminary research has indicated that dynamic muscle contractions within an optimal frequency range can significantly recover disuse induced bone loss. However, the optimal rest periods required to prevent muscle fatigue during stimulations are not clear. The overall objective of this study was to evaluate optimized dynamic muscle stimulations at relatively high frequency, e.g., 20 Hz, and to test the role of varying the rest duration on muscle mass and bone morphology in a functional hind limb disuse mouse model.


Cells ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 298
Author(s):  
Ute Nazet ◽  
Laura Feulner ◽  
Dominique Muschter ◽  
Patrick Neubert ◽  
Valentin Schatz ◽  
...  

Genetic predisposition, traumatic events, or excessive mechanical exposure provoke arthritic changes in the temporomandibular joint (TMJ). We analysed the impact of mechanical stress that might be involved in the development and progression of TMJ osteoarthritis (OA) on murine synovial fibroblasts (SFs) of temporomandibular origin. SFs were subjected to different protocols of mechanical stress, either to a high-frequency tensile strain for 4 h or to a tensile strain of varying magnitude for 48 h. The TMJ OA induction was evaluated based on the gene and protein secretion of inflammatory factors (Icam-1, Cxcl-1, Cxcl-2, Il-1ß, Il-1ra, Il-6, Ptgs-2, PG-E2), subchondral bone remodelling (Rankl, Opg), and extracellular matrix components (Col1a2, Has-1, collagen and hyaluronic acid deposition) using RT-qPCR, ELISA, and HPLC. A short high-frequency tensile strain had only minor effects on inflammatory factors and no effects on the subchondral bone remodelling induction or matrix constituent production. A prolonged tensile strain of moderate and advanced magnitude increased the expression of inflammatory factors. An advanced tensile strain enhanced the Ptgs-2 and PG-E2 expression, while the expression of further inflammatory factors were decreased. The tensile strain protocols had no effects on the RANKL/OPG expression, while the advanced tensile strain significantly reduced the deposition of matrix constituent contents of collagen and hyaluronic acid. The data indicates that the application of prolonged advanced mechanical stress on SFs promote PG-E2 protein secretion, while the deposition of extracellular matrix components is decreased.


2008 ◽  
Vol 82 (1) ◽  
pp. 88-99 ◽  
Author(s):  
Christian Windpassinger ◽  
Benedikt Schoser ◽  
Volker Straub ◽  
Sonja Hochmeister ◽  
Abdul Noor ◽  
...  

Author(s):  
Yi-Xian Qin ◽  
Hoyan Lam ◽  
Murtaza Malbari

Musculoskeletal adaptations to aging and disuse environment have significant physiological effects on skeletal health, i.e., osteopenia and bone loss. Osteoporosis often occurs together with muscle loss. Such musculoskeletal complications cause severe physiologic changes and have been proposed the synergistic effects of muscle function and bone adaptation. The role of mechanobiology in the skeletal tissue may be closely related to load-induced transductive signals, e.g., bone fluid flow, which is proposed to be a critical mediator of bone and muscle adaptation. The skeletal muscle may serve as a muscle pump that may mediate bone mechanotransduction via modulation of intramedullary pressure. Muscular stimulation (MS) is proposed to be used to simultaneously treat both muscle and bone loss. Indeed, our recent data have demonstrated that high frequency, short duration stimulation can inhibit bone loss and muscle atrophy. Although 10 min dynamic loading can effectively attenuate bone loss, it cannot totally recover disuse osteopenia. The optimal parameters required for such treatment are unclear. Studies have separately investigated the optimal signal parameters for bone or muscle. Insertion of recovery periods during high frequency stimulations to extend the loading cycles have shown potential to reduce muscle atrophy by minimizing fatigue and mimicking physiologic contractions, and demonstrated enhancement of bone remodeling. The overall hypothesis for this study is that dynamic MS can enhance anabolic activity in bone, and inhibit bone loss in a functional disuse condition. Combined high frequency and sufficient loading cycle may be able to completely mitigate bone loss induced by disuse osteopenia.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


Sign in / Sign up

Export Citation Format

Share Document