Real-time determination of kinetics of adsorption of lead(II) onto palm shell-based activated carbon using ion selective electrode

2008 ◽  
Vol 99 (13) ◽  
pp. 5786-5792 ◽  
Author(s):  
Mohamed Kheireddine Aroua ◽  
S.P.P. Leong ◽  
L.Y. Teo ◽  
Chun Yang Yin ◽  
Wan Mohd Ashri Wan Daud
Polymers ◽  
2018 ◽  
Vol 10 (11) ◽  
pp. 1275 ◽  
Author(s):  
Kun Shang ◽  
Siyu Song ◽  
Yaping Cheng ◽  
Lili Guo ◽  
Yuxin Pei ◽  
...  

A novel approach for preparing carbohydrate chips based on polydopamine (PDA) surface to study carbohydrate–lectin interactions by quartz crystal microbalance (QCM) biosensor instrument has been developed. The amino-carbohydrates were immobilized on PDA-coated quartz crystals via Schiff base reaction and/or Michael addition reaction. The resulting carbohydrate-chips were applied to QCM biosensor instrument with flow-through system for real-time detection of lectin–carbohydrate interactions. A series of plant lectins, including wheat germ agglutinin (WGA), concanavalin A (Con A), Ulex europaeus agglutinin I (UEA-I), soybean agglutinin (SBA), and peanut agglutinin (PNA), were evaluated for the binding to different kinds of carbohydrate chips. Clearly, the results show that the predicted lectin selectively binds to the carbohydrates, which demonstrates the applicability of the approach. Furthermore, the kinetics of the interactions between Con A and mannose, WGA and N-Acetylglucosamine were studied, respectively. This study provides an efficient approach to preparing carbohydrate chips based on PDA for the lectin–carbohydrate interactions study.


2001 ◽  
Vol 56 (24) ◽  
pp. 7017-7024 ◽  
Author(s):  
Xiaoyan Ji ◽  
Dongliang Chen ◽  
Tao Wei ◽  
Xiaohua Lu ◽  
Yanru Wang ◽  
...  

1997 ◽  
Vol 3 (3) ◽  
pp. 231-247 ◽  
Author(s):  
L. H. Catalani ◽  
A. M. Rabello ◽  
F. H. Florenzano ◽  
M. J. Politi ◽  
W. F. Reed

1981 ◽  
Vol 46 (2) ◽  
pp. 368-376 ◽  
Author(s):  
Josef Veselý

Titration of sulphates with lead perchlorate employing lead ion selective electrode indication was studied using additions of various organic solvents at different pH' and ionic strength values. As the optimum emerged systems with 60-70% 1,4-dioxane, pH' 5.3-5.6. After dehydration with sodium hydroxide, dioxane must be freed from the electrode surface-oxidizing impurities by their reduction with sodium metal and subsequent distillation. The method was applied to determination of sulphates in mountain spring waters. Units of ppm can be determined; the limit of determination, however, depends considerably on the content of dioxane, total salt content in the sample, and speed of the semi-automatic titration. Lead can be determined with EDTA in concentrations down to c(Pb2+) = 5 . 10-6 mol l-1.


Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 155
Author(s):  
Yan Su ◽  
Ting Liu ◽  
Caiqiao Song ◽  
Aiqiao Fan ◽  
Nan Zhu ◽  
...  

As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.


Sign in / Sign up

Export Citation Format

Share Document