scholarly journals Millisecond Time-lapsed Monitoring of ATP Hydrolysis by Human Eg5 Kinesin: Real-time Dynamics of Conformation and Chemistry in vitro

2009 ◽  
Vol 96 (3) ◽  
pp. 507a ◽  
Author(s):  
Bokkyoo Jun ◽  
Sunyoung Kim
2010 ◽  
Vol 207 (12) ◽  
pp. 2733-2749 ◽  
Author(s):  
Rachel S. Friedman ◽  
Peter Beemiller ◽  
Caitlin M. Sorensen ◽  
Jordan Jacobelli ◽  
Matthew F. Krummel

The real-time dynamics of the T cell receptor (TCR) reflect antigen detection and T cell signaling, providing valuable insight into the evolving events of the immune response. Despite considerable advances in studying TCR dynamics in simplified systems in vitro, live imaging of subcellular signaling complexes expressed at physiological densities in intact tissues has been challenging. In this study, we generated a transgenic mouse with a TCR fused to green fluorescent protein to provide insight into the early signaling events of the immune response. To enable imaging of TCR dynamics in naive T cells in the lymph node, we enhanced signal detection of the fluorescent TCR fusion protein and used volumetric masking with a second fluorophore to mark the T cells expressing the fluorescent TCR. These in vivo analyses and parallel experiments in vitro show minimal and transient incorporation of TCRs into a stable central supramolecular activating cluster (cSMAC) structure but strong evidence for rapid, antigen-dependent TCR internalization that was not contingent on T cell motility arrest or cSMAC formation. Short-lived antigen-independent TCR clustering was also occasionally observed. These in vivo observations demonstrate that varied TCR trafficking and cell arrest dynamics occur during early T cell activation.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Hafiz Muhammad Umer Farooqi ◽  
Bohye Kang ◽  
Muhammad Asad Ullah Khalid ◽  
Abdul Rahim Chethikkattuveli Salih ◽  
Kinam Hyun ◽  
...  

AbstractHepatic fibrosis is a foreshadowing of future adverse events like liver cirrhosis, liver failure, and cancer. Hepatic stellate cell activation is the main event of liver fibrosis, which results in excessive extracellular matrix deposition and hepatic parenchyma's disintegration. Several biochemical and molecular assays have been introduced for in vitro study of the hepatic fibrosis progression. However, they do not forecast real-time events happening to the in vitro models. Trans-epithelial electrical resistance (TEER) is used in cell culture science to measure cell monolayer barrier integrity. Herein, we explored TEER measurement's utility for monitoring fibrosis development in a dynamic cell culture microphysiological system. Immortal HepG2 cells and fibroblasts were co-cultured, and transforming growth factor β1 (TGF-β1) was used as a fibrosis stimulus to create a liver fibrosis-on-chip model. A glass chip-based embedded TEER and reactive oxygen species (ROS) sensors were employed to gauge the effect of TGF-β1 within the microphysiological system, which promotes a positive feedback response in fibrosis development. Furthermore, albumin, Urea, CYP450 measurements, and immunofluorescent microscopy were performed to correlate the following data with embedded sensors responses. We found that chip embedded electrochemical sensors could be used as a potential substitute for conventional end-point assays for studying fibrosis in microphysiological systems.


Author(s):  
Hanieh Gholizadeh ◽  
Hui Xin Ong ◽  
Peta Bradbury ◽  
Agisilaos Kourmatzis ◽  
Daniela Traini ◽  
...  

2021 ◽  
Vol 186 (Supplement_1) ◽  
pp. 370-377
Author(s):  
Edward Chaum ◽  
Ernő Lindner

ABSTRACT Background Target-controlled infusion anesthesia is used worldwide to provide user-defined, stable, blood concentrations of propofol for sedation and anesthesia. The drug infusion is controlled by a microprocessor that uses population-based pharmacokinetic data and patient biometrics to estimate the required infusion rate to replace losses from the blood compartment due to drug distribution and metabolism. The objective of the research was to develop and validate a method to detect and quantify propofol levels in the blood, to improve the safety of propofol use, and to demonstrate a pathway for regulatory approval for its use in the USA. Methods We conceptualized and prototyped a novel “smart” biosensor-enabled intravenous catheter capable of quantifying propofol at physiologic levels in the blood, in real time. The clinical embodiment of the platform is comprised of a “smart” biosensor-enabled catheter prototype, a signal generation/detection readout display, and a driving electronics software. The biosensor was validated in vitro using a variety of electrochemical methods in both static and flow systems with biofluids, including blood. Results We present data demonstrating the experimental detection and quantification of propofol at sub-micromolar concentrations using this biosensor and method. Detection of the drug is rapid and stable with negligible biofouling due to the sensor coating. It shows a linear correlation with mass spectroscopy methods. An intuitive graphical user interface was developed to: (1) detect and quantify the propofol sensor signal, (2) determine the difference between targeted and actual propofol concentration, (3) communicate the variance in real time, and (4) use the output of the controller to drive drug delivery from an in-line syringe pump. The automated delivery and maintenance of propofol levels was demonstrated in a modeled benchtop “patient” applying the known pharmacokinetics of the drug using published algorithms. Conclusions We present a proof-of-concept and in vitro validation of accurate electrochemical quantification of propofol directly from the blood and the design and prototyping of a “smart,” indwelling, biosensor-enabled catheter and demonstrate feedback hardware and software architecture permitting accurate measurement of propofol in blood in real time. The controller platform is shown to permit autonomous, “closed-loop” delivery of the drug and maintenance of user-defined propofol levels in a dynamic flow model.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Pascal Donsbach ◽  
Dagmar Klostermeier

Abstract RNA helicases are a ubiquitous class of enzymes involved in virtually all processes of RNA metabolism, from transcription, mRNA splicing and export, mRNA translation and RNA transport to RNA degradation. Although ATP-dependent unwinding of RNA duplexes is their hallmark reaction, not all helicases catalyze unwinding in vitro, and some in vivo functions do not depend on duplex unwinding. RNA helicases are divided into different families that share a common helicase core with a set of helicase signature motives. The core provides the active site for ATP hydrolysis, a binding site for the non-sequence-specific interactions with RNA, and in many cases a basal unwinding activity. Its activity is often regulated by flanking domains, by interaction partners, or by self-association. In this review, we summarize the regulatory mechanisms that modulate the activities of the helicase core. Case studies on selected helicases with functions in translation, splicing, and RNA sensing illustrate the various modes and layers of regulation in time and space that harness the helicase core for a wide spectrum of cellular tasks.


Sign in / Sign up

Export Citation Format

Share Document