A new family of actinide sorbents with more open porous structure: Fibrous functionalized silica microspheres

2020 ◽  
Vol 385 ◽  
pp. 123892 ◽  
Author(s):  
Li-Yong Yuan ◽  
Ge Gao ◽  
Chuan-Qi Feng ◽  
Zhi-Fang Chai ◽  
Wei-Qun Shi
2007 ◽  
Vol 28 (11) ◽  
pp. 931-933 ◽  
Author(s):  
Jianfeng LI ◽  
Jiulong YANG ◽  
Miaomiao WANG ◽  
Yong LU ◽  
Mingyuan HE

RSC Advances ◽  
2015 ◽  
Vol 5 (25) ◽  
pp. 19082-19090 ◽  
Author(s):  
Heyong Cheng ◽  
Chunling Wu ◽  
Jinhua Liu ◽  
Zigang Xu

Thiol-functionalized silica microspheres were synthesized from aminosilica for online mercury preconcentration, followed by high performance liquid chromatographic separation and inductively coupled plasma mass spectrometry detection.


2016 ◽  
Vol 22 (4) ◽  
pp. 752-765 ◽  
Author(s):  
Jatender Pal Singh ◽  
Pulak M. Pandey ◽  
Anita Kamra Verma

Purpose Scaffolds are essentially required to have open porous structure for facilitating bone to grow. They are generally placed on those bone defective/fractured sites which are more prone to compressive loading. Open porous structure lacks in strength in comparison to solid. Selective laser sintering (SLS) process is prominently used for fabrication of polymer/composite scaffolds. So, this paper aims to study for fabrication of three-dimensional open porous scaffolds with enhanced strength, process parameters of SLS of a biocompatible material are required to be optimized. Design/methodology/approach Regular open porous structures with suitable pore size as per computer-aided design models were fabricated using SLS. Polyamide (PA-2200) was used to fabricate the specimen/scaffold. To optimize the strength of the designed structure, response surface methodology was used to design the experiments. Specimens as per ASTM D695 were fabricated using SLS and compressive testing was carried out. Analysis of variance was done for estimating contribution of individual process parameters. Optimized process parameters were obtained using a trust region algorithm and correlated with experimental results. Accuracy of the fabricated specimen/scaffold was also assessed in terms of IT grades. In vitro cell culture on the fabricated structures confirmed the biocompatibility of polyamide (PA-2200). Findings Optimized process parameters for open cell process structures were obtained and confirmed experimentally. Laser power, hatch spacing and layer thickness have contributed more in the porous part’s strength than scan speed. The accuracy of the order of IT16 has been found for all functional dimensions. Cell growth and proliferation confirmed biocompatibility of polyamide (PA-2200) for scaffold applications. Originality/value This paper demonstrates the biocompatibility of PA-2200 for scaffold applications. The optimized process parameters of SLS process for open cell structure having pore size 1.2 × 1.2 mm2 with strut diameter of 1 mm have been obtained. The accuracy of the order of IT16 was obtained at the optimized process factors.


2011 ◽  
Vol 2 (5) ◽  
pp. 493-498 ◽  
Author(s):  
O. V. Arzhakova ◽  
A. A. Dolgova ◽  
L. M. Yarysheva ◽  
A. L. Volynskii ◽  
N. F. Bakeev

Sign in / Sign up

Export Citation Format

Share Document