scholarly journals An automated cluster surface scanning method for exploring reaction paths on metal-cluster surfaces

2021 ◽  
Vol 186 ◽  
pp. 110010
Author(s):  
Sean A. Tacey ◽  
Benjamin W.J. Chen ◽  
Tibor Szilvási ◽  
Manos Mavrikakis
2020 ◽  
Vol 55 (8) ◽  
pp. 1448-1452 ◽  
Author(s):  
Xicheng Deng ◽  
Peng Huang ◽  
Jinwen Luo ◽  
Jinghua Wang ◽  
Liwen Yi ◽  
...  

Open Physics ◽  
2010 ◽  
Vol 8 (2) ◽  
Author(s):  
Juha Saarela ◽  
Torbjörn Löfqvist ◽  
Kerstin Ramser ◽  
Per Gren ◽  
Erik Olson ◽  
...  

AbstractThis study is focused on exploring the feasibility of an all-optic surface scanning method in determining the size and position of a submerged, laser generated, optoacoustic (OA) source. The optoacoustic effect in this case was generated when the absorption of a short electromagnetic pulse in matter caused a dielectric breakdown, a plasma emission flash and a subsequent acoustic wave. In the experiment, a laser pulse with λ = 1064 nm and 12 ns pulse length was aimed at a volume of deionized water. When the laser beam was focused by a f = 16 mm lens, a single dielectric breakdown spot occurred. When a f = 40 mm was used several breakdowns in a row were induced. The breakdowns were photographed using a double shutter camera. The acoustic wave generated by the dielectric breakdowns were detected at a point on the water surface using a laser Doppler vibrometer (LDV). First, the LDV signal was used to calculate the speed of sound with an accuracy of 10 m/s. Secondly, the location and length of the dielectric breakdown was calculated with an accuracy of 1 mm. The calculated position matched the breakdown location recorded by a camera. The results show that it is possible to use LDV surface measurements from a single spot to determine both the position and length of the OA source as well as the speed of sound in the medium. Furthermore, the LDV measurements also show a secondary peak that originates from the OA source. To unravel the origin and properties of this interesting feature, further investigations are necessary


PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0262296
Author(s):  
Pawel Kudzia ◽  
Erika Jackson ◽  
Genevieve Dumas

Body segment parameters are inputs for a range of applications. Participant-specific estimates of body segment parameters are desirable as this requires fewer prior assumptions and can reduce outcome measurement errors. Commonly used methods for estimating participant-specific body segment parameters are either expensive and out of reach (medical imaging), have many underlying assumptions (geometrical modelling) or are based on a specific subset of a population (regression models). Our objective was to develop a participant-specific 3D scanning and body segmentation method that estimates body segment parameters without any assumptions about the geometry of the body, ethnic background, and gender, is low-cost, fast, and can be readily available. Using a Microsoft Kinect Version 2 camera, we developed a 3D surface scanning protocol that enabled the estimation of participant-specific body segment parameters. To evaluate our system, we performed repeated 3D scans of 21 healthy participants (10 male, 11 female). We used open source tools to segment each body scan into 16 segments (head, torso, abdomen, pelvis, left and right hand, forearm, upper arm, foot, shank and thigh) and wrote custom software to estimate each segment’s mass, mass moment of inertia in the three principal orthogonal axes relevant to the center of the segment, longitudinal length, and center of mass. We compared our body segment parameter estimates to those obtained using two comparison methods and found that our system was consistent in estimating total body volume between repeated scans (male p = 0.1194, female p = 0.2240), estimated total body mass without significant differences when compared to our comparison method and a medical scale (male p = 0.8529, female p = 0.6339), and generated consistent and comparable estimates across a range of the body segment parameters of interest. Our work here outlines and provides the code for an inexpensive 3D surface scanning method for estimating a range of participant-specific body segment parameters.


Author(s):  
L. T. Germinario

Understanding the role of metal cluster composition in determining catalytic selectivity and activity is of major interest in heterogeneous catalysis. The electron microscope is well established as a powerful tool for ultrastructural and compositional characterization of support and catalyst. Because the spatial resolution of x-ray microanalysis is defined by the smallest beam diameter into which the required number of electrons can be focused, the dedicated STEM with FEG is the instrument of choice. The main sources of errors in energy dispersive x-ray analysis (EDS) are: (1) beam-induced changes in specimen composition, (2) specimen drift, (3) instrumental factors which produce background radiation, and (4) basic statistical limitations which result in the detection of a finite number of x-ray photons. Digital beam techniques have been described for supported single-element metal clusters with spatial resolutions of about 10 nm. However, the detection of spurious characteristic x-rays away from catalyst particles produced images requiring several image processing steps.


Author(s):  
R. Levi-Setti ◽  
J.M. Chabala ◽  
Y.L. Wang

Finely focused beams extracted from liquid metal ion sources (LMIS) provide a wealth of secondary signals which can be exploited to create high resolution images by the scanning method. The images of scanning ion microscopy (SIM) encompass a variety of contrast mechanisms which we classify into two broad categories: a) Emission contrast and b) Analytical contrast.Emission contrast refers to those mechanisms inherent to the emission of secondaries by solids under ion bombardment. The contrast-carrying signals consist of ion-induced secondary electrons (ISE) and secondary ions (ISI). Both signals exhibit i) topographic emission contrast due to the existence of differential geometric emission and collection effects, ii) crystallographic emission contrast, due to primary ion channeling phenomena and differential oxidation of crystalline surfaces, iii) chemical emission or Z-contrast, related to the dependence of the secondary emission yields on the Z and surface chemical state of the target.


Author(s):  
Richard D. Powell ◽  
James F. Hainfeld ◽  
Carol M. R. Halsey ◽  
David L. Spector ◽  
Shelley Kaurin ◽  
...  

Two new types of covalently linked, site-specific immunoprobes have been prepared using metal cluster labels, and used to stain components of cells. Combined fluorescein and 1.4 nm “Nanogold” labels were prepared by using the fluorescein-conjugated tris (aryl) phosphine ligand and the amino-substituted ligand in the synthesis of the Nanogold cluster. This cluster label was activated by reaction with a 60-fold excess of (sulfo-Succinimidyl-4-N-maleiniido-cyclohexane-l-carboxylate (sulfo-SMCC) at pH 7.5, separated from excess cross-linking reagent by gel filtration, and mixed in ten-fold excess with Goat Fab’ fragments against mouse IgG (obtained by reduction of F(ab’)2 fragments with 50 mM mercaptoethylamine hydrochloride). Labeled Fab’ fragments were isolated by gel filtration HPLC (Superose-12, Pharmacia). A combined Nanogold and Texas Red label was also prepared, using a Nanogold cluster derivatized with both and its protected analog: the cluster was reacted with an eight-fold excess of Texas Red sulfonyl chloride at pH 9.0, separated from excess Texas Red by gel filtration, then deprotected with HC1 in methanol to yield the amino-substituted label.


2020 ◽  
Vol 118 (1) ◽  
pp. 106
Author(s):  
Lei Zhang ◽  
Jianliang Zhang ◽  
Kexin Jiao ◽  
Guoli Jia ◽  
Jian Gong ◽  
...  

The three-dimensional (3D) model of erosion state of blast furnace (BF) hearth was obtained by using 3D laser scanning method. The thickness of refractory lining can be measured anywhere and the erosion curves were extracted both in the circumferential and height directions to analyze the erosion characteristics. The results show that the most eroded positions located below 20# tuyere with an elevation of 7700 mm and below 24#–25# tuyere with an elevation of 8100 mm, the residual thickness here is only 295 mm. In the circumferential directions, the serious eroded areas located between every two tapholes while the taphole areas were protected well by the bonding material. In the height directions, the severe erosion areas located between the elevation of 7600 mm to 8200 mm. According to the calculation, the minimum depth to ensure the deadman floats in the hearth is 2581 mm, corresponding to the elevation of 7619 mm. It can be considered that during the blast furnace production process, the deadman has been sinking to the bottom of BF hearth and the erosion areas gradually formed at the root of deadman.


Author(s):  
Jeff Dunnihoo ◽  
Pasi Tamminen ◽  
Toni Viheriäkoski

Abstract In this study we present a novel method to use a field collapse method together with fully automated near field scanning equipment to construct E- and H-field information of a system during transient ESD events. This inexpensive method provides an alternative way for system designers to validate and analyze the EMC/ESD capability of electronic systems without TLP pulsers, ESD simulators, or precision inductive current probes.


Sign in / Sign up

Export Citation Format

Share Document