scholarly journals Shear capacity of masonry walls externally strengthened using Flax-TRM composite systems: experimental tests and comparative assessment

2020 ◽  
Vol 261 ◽  
pp. 120490
Author(s):  
Giuseppe Ferrara ◽  
Carmelo Caggegi ◽  
Enzo Martinelli ◽  
Aron Gabor
2020 ◽  
Vol 21 (5) ◽  
pp. 1777-1793
Author(s):  
Beatrice Belletti ◽  
Jesús Rodríguez ◽  
Carmen Andrade ◽  
Lorenzo Franceschini ◽  
Javier Sánchez Montero ◽  
...  

2021 ◽  
Vol 881 ◽  
pp. 149-156
Author(s):  
Mochamad Teguh ◽  
Novi Rahmayanti ◽  
Zakki Rizal

Building material innovations in various interlocking concrete block masonry from local materials to withstand lateral earthquake forces is an exciting issue in masonry wall research. The block hook has an advantage in the interlocking system's invention to withstand loads in the in-plane and out-of-plane orientations commonly required by the masonry walls against earthquake forces. Reviews of the investigation of in-plane and out-of-plane masonry walls have rarely been found in previous studies. In this paper, the results of a series of experimental tests with different interlocking models in resisting the simultaneous in-plane shear and out-of-plane bending actions on concrete blocks are presented. This paper presents a research investigation of various interlocking concrete blocks' mechanical properties with different hook thicknesses. Discussion of the trends mentioned above and their implications towards interlocking concrete block mechanical properties is provided.


2017 ◽  
Vol 747 ◽  
pp. 319-325 ◽  
Author(s):  
Matteo Maragna ◽  
Cristina Gentilini ◽  
Giovanni Castellazzi ◽  
Christian Carloni

In this paper, the preliminary results of a series of pull-out tests conducted on mortar cylinders with embedded bars are presented. The bars are made of high strength stainless steel and are of helical shape to increase mechanical interlocking with the surrounding mortar. Usually, such bars are employed in situ to realize structural repointing in the case of fair-faced masonry walls. To this aim, they are inserted in the mortar bed joints of masonry for providing tensile strength to the walls and with the function of crack stitching. The aim of the present experimental tests is to determine the bond-slip relationship for bars embedded in masonry. Firstly, pull-out tests are conducted on mortar cylinders considering different embedded lengths of the bars. Further tests are on-going on masonry specimens with bars embedded in the mortar joints. An analytical investigation is also carried out for the interpretation of the pull-out test results.


2018 ◽  
Vol 9 (3) ◽  
pp. 281-295 ◽  
Author(s):  
Patricia Raposo ◽  
André Furtado ◽  
António Arêde ◽  
Humberto Varum ◽  
Hugo Rodrigues

Purpose The infill masonry walls in recent worldwide earthquakes have shown that it is necessary to conduct further studies to characterize the behavior of existing buildings and, in particular, of infill masonry walls under seismic activity. The lack of characterization studies of infill walls made by concrete blocks justifies the investigation reported herein, which includes experimental tests on sample sets to evaluate the mechanical properties of masonry components (units and mortar) and assemblages (wallets) made with masonry units from Faial. For the later, normal compressive, diagonal tensile/shear and out-of-plane flexural strengths were obtained according to standard procedures, the results of which are presented in the manuscript. The paper aims to discuss these issues. Design/methodology/approach One experimental campaign was conducted with the aim to mechanically characterize concrete blocks masonry samples. Several experimental tests were carried out in full-scale masonry concrete wallets according to the constructive methodology used. Findings Based on the data obtained from the mechanical characterization tests of the concrete masonry blocks, it can be seen that under simple compression, the masonry specimens’ average resistance is about 6 times superior than the average resistance to diagonal shear/tension, while the stiffness is almost doubled. In simple compression tests, it was observed that the masonry specimens cracked in areas of higher drilling of the blocks. In the tensile tests by diagonal compression, it was found that the test specimens were mainly fissured by the block/mortar joint interfaces, following the delineation of settlement and top joints. Originality/value There are no experimental results available in the literature for this type of bricks that can contribute to the development of numerical studies.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Donia Salman ◽  
Rabab Allouzi ◽  
Nasim Shatarat

PurposeThe main goal is to investigate the effect of size and location of opening and column size on the punching shear strength. Openings are often needed in order to install mechanical and electrical services. This process takes away part of the concrete volume which is responsible for resisting the shear forces and any unbalanced moment. Furthermore, the application of rectangular columns in flat slabs is commonly used in practice as they provide lateral stiffness to the building. They are also utilised in garages and multi-storey buildings where these elongated cross-sectional columns reduce the effective span length between adjacent columns.Design/methodology/approachThis research is a numerical-based investigation that is calibrated based on a thirteen previously tested and numerically calibrated slab specimens with no openings. A parametric study is conducted in this study to consider the effect of other parameters, which are the size and location of opening and the rectangularity ratio of column in order to evaluate their effect on the punching shear capacity. A total of 156 models are developed to study these factors. Additionally, the predicted shear carrying capacity of the simulated slabs is calculated using the ACI318–19 and Eurocode (EC2-04) equation.FindingsThe presence of openings reduced the punching shear capacity. The small opening's location and orientation have almost no effect except for one slab. For slabs of large openings, the presence of openings reduced the punching capacity. The punching capacity is higher when the openings are farther from the column. The numerically obtained results of slabs with rectangular columns show lower punching capacity compared to slabs of squared columns with the same length of the punching shear control perimeter. The punching capacity for all slabs is predicted by ACI318–19 and Eurocode (EC2-04) and it is found that Eurocode (EC2-04) provided a closer estimation.Originality/valueThe slabs considered for calibration were reinforced with four different punching shear reinforcement configurations, namely; ordinary closed rectangular stirrups, rectangular spiral stirrups, advanced rectangular spiral stirrups and circular spiral. Generally, there has been limited research on concrete flat slabs with openings in comparison with other subjects related to structural engineering (Guan, 2009) and no research on punching shear with openings of slabs reinforced with these reinforcement schemes. The available research focussed on the effects of openings on the flexural behaviour of reinforced concrete slabs includes Casadei et al. (2003), Banu et al. (2012) and Elsayed et al. (2009). In addition, experimental tests that examined slabs supported on rectangular columns are very limited.


Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5780
Author(s):  
Thomas Celano ◽  
Luca Umberto Argiento ◽  
Francesca Ceroni ◽  
Claudia Casapulla

This paper presents the results of several numerical analyses aimed at investigating the in-plane resistance of masonry walls by means of two modelling approaches: a finite element model (FEM) and a discrete macro-element model (DMEM). Non-linear analyses are developed, in both cases, by changing the mechanical properties of masonry (compressive and tensile strengths, fracture energy in compression and tension, shear strength) and the value of the vertical compression stress applied on the walls. The reliability of both numerical models is firstly checked by means of comparisons with experimental tests available in the literature. The analyses show that the numerical results provided by the two modelling approaches are in good agreement, in terms of both failure loads and modes, while some differences are observed in their load-displacement curves, especially in the non-linear field. Finally, the numerical in-plane resistances are compared with the theoretical formulations provided by the Italian building code for both flexural and shear failure modes and an amendment for the shape factor ‘b’ introduced in the code formulation for squat walls is proposed.


Materials ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6103
Author(s):  
Zheng-Nan Jing ◽  
Rong-Gui Liu ◽  
Gui-Hua Xie ◽  
Dan Liu

Deep T-section beams have been widely used in engineering structures due to their high bearing capacity, high construction efficiency and economic benefits, while the current beam design theory can hardly interpret reasonably the mechanical behaviors of deep beams. The performance features of the deep T-beam were investigated, involving in strain distribution and principal stress trace using experimental tests. Different near surface mounted (NSM) reinforcement schemes were proposed for deep T-beams aiming at improving the shear capacity. The results show that the behaviors of deep T-beams dissatisfy the assumption of plane cross-section, and the ‘strut-and-tie’ model is applicable in such structures. The reinforcement systems can significantly relieve the strain concentration, mid-span deflection and crack width in deep T-beams, consequently improving the shear capacity range from 45 to 65%. The scheme is preferential for the reinforcement of deep T-beams when the applied angles, positions and lengths of CFRP bars are optimized based on the ‘strut-and-tie’ model.


2015 ◽  
Vol 5 (1) ◽  
pp. 69-74 ◽  
Author(s):  
Eva Partene ◽  
Luminita Fekete-Nagy ◽  
V. Stoian

Abstract The papers presents the results of an experimental program and provides valuable information regarding the behaviour of structural masonry walls built up using ceramic blocks with hollows, which represents a very common system for low-rise residential buildings, up to 4 stories, depending on the seismic acceleration on site. A number of six masonry walls where tested in bear state being subjected to constant vertical loading and to cyclic in-plane horizontal loads. The main objective was to determine the shear capacity for unreinforced masonry walls and reinforced masonry walls. The experimental results were also useful to determine the contribution of the reinforcing of the masonry walls with concrete columns. The comparison between unreinforced masonry and reinforced masonry has a great importance due to the fact that the Romanian Seismic Standards have imposed the reinforcement in seismic areas for building with more than 1 storey. Further studies will be conducted on strengthening the masonry walls using FRP materials.


Sign in / Sign up

Export Citation Format

Share Document