Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: A case study

2013 ◽  
Vol 60 ◽  
pp. 163-173 ◽  
Author(s):  
Hua Ge ◽  
Victoria Ruth McClung ◽  
Shenshu Zhang
Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1211
Author(s):  
Francesco Zaccaro ◽  
John Richard Littlewood ◽  
Carolyn Hayles

Calculating Repeating Thermal Bridges (RTBs) for Timber Frame (TF) closed panels that could occur in Offsite Manufactured (OSM) Modern Methods of Construction (MMC), such as exterior walls for nearly-to-zero operational energy dwellings to be constructed in Wales, United Kingdom (UK) is discussed in this paper. Detailed calculations for linear RTBs due to the TF components are often neglected when evaluating thermal transmittance (known as U-values hereafter). The use of standard TF fractions does not allow the designer to perceive their detrimental impact on RTBs and consequent U-values for exterior walls. With the increase of the thermal performance of exterior walls and as such lower U-values due to ever-tightening Building Regulations, specifically related to the energy use and carbon emissions from the space heating of dwellings, then the impacts of RTBs requires more investigation. By not calculating the potential of linear RTB at the design stage could lead to a performance gap where assumed U-values for exterior walls differ from manufacture to onsite. A TF detail from the Welsh manufacture has been chosen as a case study, to develop and apply a methodology using manufacturing drawings to evaluate TF fraction and their effect on the thermal performance.


2011 ◽  
Vol 39 (5) ◽  
pp. 1195-1212
Author(s):  
Ahmed Aly ◽  
Esam El-Din Kamal Mahrous ◽  
Ezzat Abd El-Moniem Morghany ◽  
Essam Salah Said Abdel Magid

Author(s):  
Junaidah Jailani ◽  
◽  
Norsyalifa Mohamad ◽  
Muhammad Amirul Omar ◽  
Hauashdh Ali ◽  
...  

According to the National Energy Balance report released by the Energy Commission of Malaysia in 2016, the residential sector uses 21.6% of the total energy in Malaysia. Residents waste energy through inefficient energy consumption and a lack of awareness. Building occupants are considered the main factor that influences energy consumption in buildings, and to change energy consumption on an overall scale, it is crucial to change individual behaviour. Therefore, this study focused on analysing the energy consumption pattern and the behaviour of consumers towards energy consumption in their homes in the residential area of Batu Pahat, Johor. A self-administrated questionnaire approach was employed in this study. The findings of this study showed that the excessive use of air conditioners was a significant factor in the increasing electricity bills of homeowners as well as the inefficient use of electrical appliances. Also, this study determined the effect of awareness on consumer behaviour. This study recommends ways to help minimise energy consumption in the residential area.


2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


Sign in / Sign up

Export Citation Format

Share Document