scholarly journals An Analysis of Repeating Thermal Bridges from Timber Frame Fraction in Closed Panel Timber Frame Walls: A Case Study from Wales, UK

Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1211
Author(s):  
Francesco Zaccaro ◽  
John Richard Littlewood ◽  
Carolyn Hayles

Calculating Repeating Thermal Bridges (RTBs) for Timber Frame (TF) closed panels that could occur in Offsite Manufactured (OSM) Modern Methods of Construction (MMC), such as exterior walls for nearly-to-zero operational energy dwellings to be constructed in Wales, United Kingdom (UK) is discussed in this paper. Detailed calculations for linear RTBs due to the TF components are often neglected when evaluating thermal transmittance (known as U-values hereafter). The use of standard TF fractions does not allow the designer to perceive their detrimental impact on RTBs and consequent U-values for exterior walls. With the increase of the thermal performance of exterior walls and as such lower U-values due to ever-tightening Building Regulations, specifically related to the energy use and carbon emissions from the space heating of dwellings, then the impacts of RTBs requires more investigation. By not calculating the potential of linear RTB at the design stage could lead to a performance gap where assumed U-values for exterior walls differ from manufacture to onsite. A TF detail from the Welsh manufacture has been chosen as a case study, to develop and apply a methodology using manufacturing drawings to evaluate TF fraction and their effect on the thermal performance.

2021 ◽  
Author(s):  
Kaitlin Paige Carroll

This study assesses the performance gap between actual energy performance and desired energy performance outcomes for a case study of 19 LEED-certified multi-unit residential buildings in the Greater Toronto Area. The study examines 1) how accurately design-stage energy modelling predicts actual energy use, 2) how much variation of energy performance can be seen between buildings of the same level of certification, and 3) the key contributing factors of this performance gap. Using EUI as the basis of comparison, trend analysis was carried out. It was determined that a performance gap between modelled and actual building energy use does exist. When compared to a larger sample of existing buildings, the case study buildings show no real improvement, on average. Regression models revealed no strong correlation between LEED Level or LEED EAc1 credits and reduced EUIs.


2021 ◽  
Author(s):  
Kaitlin Paige Carroll

This study assesses the performance gap between actual energy performance and desired energy performance outcomes for a case study of 19 LEED-certified multi-unit residential buildings in the Greater Toronto Area. The study examines 1) how accurately design-stage energy modelling predicts actual energy use, 2) how much variation of energy performance can be seen between buildings of the same level of certification, and 3) the key contributing factors of this performance gap. Using EUI as the basis of comparison, trend analysis was carried out. It was determined that a performance gap between modelled and actual building energy use does exist. When compared to a larger sample of existing buildings, the case study buildings show no real improvement, on average. Regression models revealed no strong correlation between LEED Level or LEED EAc1 credits and reduced EUIs.


2021 ◽  
Vol 1 ◽  
pp. 3279-3288
Author(s):  
Maria Hein ◽  
Darren Anthony Jones ◽  
Claudia Margot Eckert

AbstractEnergy consumed in buildings is a main contributor to CO2 emissions, there is therefore a need to improve the energy performance of buildings, particularly commercial buildings whereby building service systems are often substantially over-designed due to the application of excess margins during the design process.The cooling system of an NHS Hospital was studied and modelled in order to identify if the system was overdesigned, and to quantify the oversizing impact on the system operational and embodied carbon footprints. Looking at the operational energy use and environmental performance of the current system as well as an alternative optimised system through appropriate modelling and calculation, the case study results indicate significant environmental impacts are caused by the oversizing of cooling system.The study also established that it is currently more difficult to obtain an estimate of the embodied carbon footprint of building service systems. It is therefore the responsibility of the machine builders to provide information and data relating to the embodied carbon of their products, which in the longer term, this is likely to become a standard industry requirement.


2021 ◽  
Vol 13 (17) ◽  
pp. 9591
Author(s):  
Sepehr Abrishami ◽  
Rocío Martín-Durán

The main goal of this study is to explore the adoption of a design for manufacturing and assembly (DfMA) and building information management (BIM) approach during the whole lifecycle of assets. This approach aims to tackle issues inherent in the design of traditional construction methods, such as low productivity and quality, poor predictability and building performance, and energy use, through the implementation of a BIM library of off-site components. In recent years, a renewed interest has been directed to the attempt to provide solutions to these urgent problems through the adoption of new advancements in technologies. However, while there are studies focussing on a BIM-DfMA approach, there is a lack of research regarding how this approach should be adopted during the whole lifecycle of the assets. Furthermore, to the best of our knowledge, defining an efficient way of developing a component-based BIM object library has not yet been included in any of the available studies. A mixed methodology approach has been used in this research. A conceptual framework was developed as the result of an extensive literature review to investigate new advancements in the AEC sector. Following the literature review, the framework was tested and validated through a case study based on the production and adoption of a BIM library of off-site components at the design stage of an asset. The architecture, engineering, and construction (AEC) industry has recognised the necessity of a new approach that helps to resolve the well-known issues presented in traditional methods of construction. The conceptual framework and case study proposed presents a valuable new method of construction that support the implementation of a BIM and DfMA approach, highlighting their benefits. This framework has been created using many valuable and reliable sources of information. The result of this research supports the idea of a novel new construction method that focuses on a manufacturing-digital-driven industry, with the use of DfMA in a BIM-integrated approach. This novel method will add significance and be beneficial for a wide range of aspects in the construction sector, contributing to the theoretical and practical domain.


2016 ◽  
Vol 23 (1) ◽  
pp. 67-75 ◽  
Author(s):  
Kalle KUUSK ◽  
Targo KALAMEES ◽  
Siim LINK ◽  
Simo ILOMETS ◽  
Alo MIKOLA

The paper presents a case study analysis of low-budget renovation of a typical concrete large-panel apartment building. Focus is on the measurements and analyses of energy consumption, indoor climate, CO2 concentration, air leakage rate, thermal transmittance of thermal bridges, and thermal transmittance of the building envelope before and after the renovation. Results indicate that the renovation project was generally successful, with delivered energy need de­creasing by 40% and heating energy need decreasing by 50%. However, some key problems need to be solved to achieve full energy efficiency potential of the renovation works. Those critical problems are the performance (thermal comfort, heat recovery) of ventilation systems, thermal bridges of external wall/window jamb and economic viability. Currently, a major renovation is not economically viable, therefore financial assistance to the apartment owners’ associations is required to encourage them to undertake major renovations.


2019 ◽  
Vol 38 (1) ◽  
pp. 51-67
Author(s):  
Cormac Flood ◽  
Lloyd Scott

Purpose The residential sector in Ireland accounted for 25 per cent of energy related CO2 emissions in 2016 through burning fossil fuels, a major contributor to climate change. In support of Ireland’s CO2 reduction targets, the existing housing stock could contribute greatly to the reduction of space-heating energy demand through retrofit. Approximately 50 per cent of Ireland’s 2m dwellings pre-date building regulations and are predominantly of cavity and solid wall construction, the performance of which has not been extensively investigated at present. Although commitment to thermal upgrade/retrofit of existing buildings may increase under future government policies, the poor characterisation of actual thermal performance of external walls may hinder the realisation of these targets. Thermal transmittance (U-values) of exterior walls represents a source of uncertainty when estimating the energy performance of dwellings. It has been noted in research that the standard calculation methodology for thermal transmittance should be improved. Implementing current U-value calculation methods may result in misguided retrofit strategies due to the considerable discrepancies between in situ measurements and calculated wall U-values as documented in the case studies carried out in this research. If the method of hygrothermal analysis were to be employed as a replacement for the current standard calculation, it could have significant implications for policy and retrofit decision making. The paper aims to discuss this issue. Design/methodology/approach This research project analysed a case study situated in Dublin, Ireland. The case studies offer an account of the in situ thermal transmittance of exterior walls and link these to hygrothermally simulated comparisons along with more traditional design U-values. Findings The findings of this research identify discrepancies between in situ and design U-values, using measurement, hygrothermal simulation and standard method U-value calculations. The outcomes of the research serve as an introduction to issues emanating from a larger research project in order to encourage researchers to understand and further explore the topic. Originality/value It has previously been highlighted that moisture content is linked to the increase in thermal conductivity of building materials, thus reducing the thermal effectiveness and increasing the elemental U-value. Therefore, it is vital to implement reliable prediction tools to assess potential thermal performance values. This paper presents the findings of a critical instance case study in Dublin, Ireland in which an existing west facing external wall in a semi-detached dwelling was analysed, simulated and measured to verify the elemental wall assembly and quantify thermal transmittance (U-value) incorporating the major criteria required for building performance simulation.


2014 ◽  
Vol 14 (4) ◽  
pp. 11-31 ◽  
Author(s):  
Michael Johnston ◽  
Mirko Guaralda ◽  
Sukanlaya Sawang

This research provides an assessment tool that assists the selection process of sustainability in detached suburban housing. It investigates the implications of using different design and construction methods including architecturally designed houses, developer housing and prefabricated houses. The study simulates one example of the three types of houses that have been chosen to fulfil a real client brief on a real site on the Sunshine Coast, Queensland Australia. Criteria for sustainability assessment are formulated based on literature reviews, exemplar designs and similar research projects for which the houses can be adequately evaluated. This criterion covers aspects including energy use, materials and thermal performance. The data is collected using computer models and sustainability assessment software to compare and draw conclusions on the success of each house.Our study indicates that architecturally designed housing with prefabricated building techniques are a better alternative to generic developer style housing. Our research provides an insight into the implications of three key elements of sustainability including energy use, materials and thermal performance. Designers, builders, developers and home-buyers are given an insight into some options currently available on the housing market and how the choices made during early design stages can provide a more positive environmental impact.  


Author(s):  
Amip Shah ◽  
Cullen Bash ◽  
Ratnesh Sharma ◽  
Tom Christian ◽  
Brian J. Watson ◽  
...  

Numerous evaluation metrics and standards are being proposed across industry and government to measure and monitor the energy efficiency of data centers. However, the energy use of data centers is just one aspect of the environmental impact. In this paper, we explore the overall environmental footprint of data centers beyond just energy efficiency. Building upon established procedures from the environmental sciences, we create an end-to-end life-cycle model of the environmental footprint of data centers across a diverse range of impacts. We test this model in the case study of a hypothetical 2.2-MW data center. Our analysis suggests the need for evaluation metrics that go beyond just operational energy use in order to achieve sustainable data centers.


Materials ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2392 ◽  
Author(s):  
Brzyski ◽  
Grudzińska ◽  
Majerek

This article analyses the connection of the two types of floors on the ground (floors on joists and self-supporting floors), with the external wall made of a hemp–lime composite for the occurrence of thermal bridges. Several factors that may affect the heat transfer in the junction were taken into account: the level of the floor on the ground, the wall thickness, the thermal conductivity of the composite, and the location of the timber frame construction. The technology of using hemp and lime is relatively new, and there is a lack of such analyses in the literature. The two-dimensional (2D) heat-transfer in the described construction joints was analyzed based on the finite-element method with the use of the THERM 7.4 software. The results were presented as averaged and linear thermal transmittance coefficients dependent on the above mentioned factors. The possibility of surface condensation was also checked. The differences in the values of the thermal transmittance of the junction between the two variants of ground floors reached around 0.13%–1.67% and the values of linear thermal transmittance factor reached approximately 2.43%–10.13%. The junctions with the highest floor level showed a decrease in the thermal transmittance value by about 3.00%–5.77% and in the linear thermal transmittance, by about 21.98%–53.83%, compared to the junctions with the lowest floor level. Calculations showed that almost all analyzed junctions are free from surface condensation causing mould growth, because the minimum temperature factors f0.25 were higher than 0.78 (except for junctions with the lowered floor levels). The junction with a floor on the timber joists showed better thermal parameters than the junction with a self-supporting floor in each of the analyzed variants. By increasing the level of floor insulation, it is possible to limit the thermal bridges and improve the thermal properties of the junction.


Sign in / Sign up

Export Citation Format

Share Document