scholarly journals Thermal Performance of Single-Story Air-Welled Terraced House in Malaysia: A Field Measurement Approach

2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.

Author(s):  
Pau Chung Leng ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Gabriel Hoh Teck Ling ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building by Law 1984 Malaysia has been practiced by designers for building plan submission approval. However, the effectiveness of thermal performance in landed residential buildings, despite the imposition by the by-law, has never been empirically measured and proven. Although terraced houses in Malaysia have dominated 40.9% of the total property transaction in 2019, such mass production with typical designs hardly provides its occupants with thermal comfort due to the static outdoor air condition and lack of external windows, where the conventional ventilation technique does not work well, even for houses with an air well system. Consequently, the occupants need to rely on mechanical cooling, which is a high energy-consuming component contributing to outdoor heat dissipation and therefore urban heat island effect. Thus, encouraging more effective natural ventilation to eliminate excessive heat from the indoor environment is critical. Since most of the research focuses on simulation modelling lacking sufficient empirical validation, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air well system. More importantly, the key concern as to what extent the current air well system serving as a ventilator is effective to provide better thermal performance in the single storey terraced house is to be addressed. By adopting an existing single storey air welled terrace house, the existing indoor environmental conditions and thermal performance were monitored and measured using scientific equipment, namely HOBO U12 air temperature and air humidity, the HOBO U12 anemometer and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The findings show that the air temperature of the air well ranged from 27.48°C to 30.92°C, while the mean relative humidity were from 72.67% to 79.25%. The mean air temperature for a test room (single sided ventilation room) ranged from 28.04°C to 30.92°C with a relative humidity of 70.16% to 76%. These empirical findings are of importance, offering novel policy insights and suggestions to potentially revising the existing building code standard and by laws; since the minimum provision of 10% openings has been revealed to be less effective to provide a desired thermal performance and comfort, mandatory compliance with, and the necessity for, the bylaw requirement should be revisited and further studied.


2019 ◽  
Vol 11 (20) ◽  
pp. 5730 ◽  
Author(s):  
Pau Chung Leng ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Gabriel H.T. Ling ◽  
Samsiah Abdullah ◽  
...  

In Malaysia, terraced housing hardly provides thermal comfort to the occupants. More often than not, mechanical cooling, which is an energy consuming component, contributes to outdoor heat dissipation that leads to an urban heat island effect. Alternatively, encouraging natural ventilation can eliminate heat from the indoor environment. Unfortunately, with static outdoor air conditioning and lack of windows in terraced houses, the conventional ventilation technique does not work well, even for houses with an air well. Hence, this research investigated ways to maximize natural ventilation in terraced housing by exploring the air well configurations. By adopting an existing single storey terraced house with an air well, located in Kuching, Sarawak, the existing indoor environmental conditions and thermal performance were investigated and monitored using scientific equipment, namely HOBO U12 air temperature and air humidity, the HOBO U12 anemometer and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter. For this parametric study, the DesignBuilder software was utilized. The field study illustrated that there is a need to improve indoor thermal comfort. Thus, the study further proposes improvement strategies to the existing case study house. The proposition was to turn the existing air well into a solar chimney taking into account advantages of constant and available solar radiation for stack ventilation. The results suggest that the enhanced air well was able to improve the indoor room air velocity and reduce air temperature. The enhanced air well with 3.5 m height, 1.0 m air gap width, 2.0 m length was able to induce higher air velocity. During the highest air temperature hour, the indoor air velocity in existing test room increased from 0.02 m/s in the existing condition to 0.29 m/s in the hottest day with 2.06 °C air temperature reduction. The findings revealed that the proposed air well could enhance the thermal and ventilation performance under the Malaysia tropical climate.


2018 ◽  
Vol 34 ◽  
pp. 02053
Author(s):  
Esra’a Sh. Abbaas ◽  
Ala’eddin A. Saif ◽  
MAC Munaaim ◽  
Md. Azree Othuman Mydin

The influence of courtyard on the thermal performance of Development Department office building in University Malaysia Perlis (UniMAP, Pauh Putra campus) is investigated through simulation study for the effect of ventilation on indoor air temperature and relative humidity of the building. The study is carried out using EnergyPlus simulator interface within OpenStudio and SketchUp plug in software to measure both of air temperature and relative humidity hourly on 21 April 2017 as a design day. The results show that the ventilation through the windows facing the courtyard has sufficient effect on reducing the air temperature compared to the ventilation through external windows since natural ventilation is highly effective on driving the indoor warm air out to courtyard. In addition, the relative humidity is reduced due to ventilation since the courtyard has high ability to remove or dilute indoor airborne pollutants coming from indoor sources. This indicates that the presence of courtyard is highly influential on thermal performance of the building.


2017 ◽  
Vol 41 (3) ◽  
pp. 225-246 ◽  
Author(s):  
Elizabeth Buechler ◽  
Simon Pallin ◽  
Philip Boudreaux ◽  
Michaela Stockdale

The indoor air temperature and relative humidity in residential buildings significantly affect material moisture durability, heating, ventilation, and air-conditioning system performance, and occupant comfort. Therefore, indoor climate data are generally required to define boundary conditions in numerical models that evaluate envelope durability and equipment performance. However, indoor climate data obtained from field studies are influenced by weather, occupant behavior, and internal loads and are generally unrepresentative of the residential building stock. Likewise, whole-building simulation models typically neglect stochastic variables and yield deterministic results that are applicable to only a single home in a specific climate. The purpose of this study was to probabilistically model homes with the simulation engine EnergyPlus to generate indoor climate data that are widely applicable to residential buildings. Monte Carlo methods were used to perform 840,000 simulations on the Oak Ridge National Laboratory supercomputer (Titan) that accounted for stochastic variation in internal loads, air tightness, home size, and thermostat set points. The Effective Moisture Penetration Depth model was used to consider the effects of moisture buffering. The effects of location and building type on indoor climate were analyzed by evaluating six building types and 14 locations across the United States. The average monthly net indoor moisture supply values were calculated for each climate zone, and the distributions of indoor air temperature and relative humidity conditions were compared with ASHRAE 160 and EN 15026 design conditions. The indoor climate data will be incorporated into an online database tool to aid the building community in designing effective heating, ventilation, and air-conditioning systems and moisture durable building envelopes.


2018 ◽  
Vol 3 (7) ◽  
pp. 357
Author(s):  
Lobna Hassan Ali Hassan Elgheriani ◽  
Parid Wardi ◽  
AbdulBasit Ali Ali Ahmed

Natural ventilation is an effectual passive design approach to create a better indoor thermal condition as well as energy efficiency. The primary goal of building design is providing a healthy and comfortable indoor environment titled as sustainable architecture. Literature suggests that the significant feature that alteration has to take place on for better energy performance is the envelope design. This paper aims to augment the Window to Wall Ratio (WWR), orientation and courtyard corridor size for improving the design of naturally ventilated courtyard high-rise residential buildings. Briefly, the findings indicate that contending with WWR, orientation and courtyard corridor size could increase the potential of improving its natural ventilation and thus, thermal performance.


2010 ◽  
Vol 39 (3) ◽  
pp. 685-694 ◽  
Author(s):  
Wander de Souza ◽  
Orlando Rus Barbosa ◽  
Jair de Araújo Marques ◽  
Marco Aurélio Teixeira Costa ◽  
Eliane Gasparino ◽  
...  

The aim of this work was to verify if the presence of trees and its height in formed silvipastoral systems with eucalyptus planted in rank can modify the microclimate and improve the environment for bovine raising during the day in summer. It was evaluated the microclimate of the environment in formed silvipastoral systems in rank of eucalyptus with 8 m, 18 m and 28 meters of height, compared to a system no shade in the summer. The experimental design was a split plot with six hour time in sub parcels. The systems are made up of parcels and the months as block in four replications and the interaction hour × system. The air temperature, black globe temperature, relative humidity and wind speed were observed to create the following indexes for thermal comfort: temperature-humidity index; black globe-humidity index; heat load index and the radiant thermal load. Excepted for the relative humidity, there was interaction for time × system for all variables and indexes. Interaction occurred for: air temperature at 10 a.m. and 6 p.m.; wind speed from 8 a.m. to 4 p.m.; temperature humidity index at 10 a.m. and 12 p.m.; black globe temperature, black globe humidity index, heat load index, and radiant thermal load at all the hours. During the summer, the system with shade of 28 m trees had the lowest average of black globe temperature; wind speed; black globe humidity index; radiant thermal load index; and heat load index. There was a reduction of wind speed average in systems 8 m, 18 m and 28 m trees in, respectively, 20.7; 50.0 and 48.0% in relation to no shade system; however it was not proportional to the height, with influence of the rank porosity and pantries height. Nevertheless, for radiant thermal load index the reduction was proportional to the height of the trees with 10.24; 12.49 and 20.76%, respectively, for 8 m, 18 m and 28 meters of height. There was a reduction of the thermal stress in the environment due to the presence of trees, being the heat load index thermal the index that better demonstrated the effect, despite of not being proportional to the rank height.


2013 ◽  
Vol 368-370 ◽  
pp. 666-669
Author(s):  
Li Li ◽  
Li Hua Zhao ◽  
Rao Chao Chen ◽  
Xiao Qing Zhou ◽  
Li Wei Xu

To study the thermal environment of the greenway in Guangzhou, a field measurement was taken and a series parameters were measured such as air temperature, relative humidity (RH), the surface temperature of the underlying and the WBGT. The measurement studied the effect of grass, shrub, arbor and water to the different underlying pattern which were water permeable brick (WP brick), cement, asphalt and tile and discussed the design methods of the greenway thermal environment.


2018 ◽  
Vol 40 ◽  
pp. 9
Author(s):  
Osvaldo Borges Pinto Junior ◽  
Sérgio Wagner Gripp Silveira ◽  
Carlo Ralph De Musis ◽  
Luiz Annunciação ◽  
Osvaldo Alves Pereira

In this study, maps of the estimated heat index for a preservation area in the city of Cuiabá, Mato Grosso, Brazil, were constructed using temperature and relative humidity gradients. Understanding microclimate variable behavior is useful for explaining the relationship between urban sprawl and increased environmental distress. The implementation and preservation of green areas is one way to mitigate the environmental impacts of human activities. Urban parks are one common type of green area in cities. According to ISO 7243, heat exposure can be assessed using the Wet Bulb Globe Temperature (WBGT). This study used multivariate statistical techniques and ordinary kriging to produce a WBGT map of the park during the dry and rainy seasons. Places with heat or freshness islands were identified. Locations along hiking trails and areas with exercise equipment were analyzed for WBGT tendencies in order to propose precautionary heat exposure measures.


Sign in / Sign up

Export Citation Format

Share Document