On the impact of user behaviour on heating energy consumption and indoor temperature in residential buildings

2021 ◽  
pp. 111657
Author(s):  
Marina Laskari ◽  
Rosa-Francesca de Masi ◽  
Stavroula Karatasou ◽  
Mat Santamouris ◽  
Margarita-Niki Assimakopoulos
Author(s):  
Shiyi Song ◽  
Hong Leng ◽  
Han Xu ◽  
Ran Guo ◽  
Yan Zhao

This study aims to acquire a better understanding of the quantitative relationship between environmental impact factors and heating energy consumption of buildings in severe cold regions. We analyze the effects of five urban morphological parameters (building density, aspect ratio, building height, floor area ratio, and shape factor) and three climatic parameters (temperature, wind speed, and relative humidity) on the heating energy use intensity (EUI) of commercial and residential buildings in a severe cold region. We develop regression models using empirical data to quantitatively evaluate the impact of each parameter. A stepwise approach is used to ensure that all the independent variables are significant and to eliminate the effects of multicollinearity. Finally, a spatial cluster analysis is performed to identify the distribution characteristics of heating EUI. The results indicate that the building height, shape factor, temperature, and wind speed have a significant impact on heating EUI, and their effects vary with the type of building. The cluster analysis indicated that the areas in the north, east, and along the river exhibited high heating EUI. The findings obtained herein can be used to evaluate building energy efficiency for urban planners and heating companies and departments based on the surrounding environmental conditions.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2538
Author(s):  
Praveen K. Cheekatamarla

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO2 per kWh electricity.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7590
Author(s):  
Adam Kula ◽  
Albert Smalcerz ◽  
Maciej Sajkowski ◽  
Zygmunt Kamiński

There are many papers concerning the consumption of energy in different buildings. Most describe residential buildings, with only a few about office- or public service buildings. Few articles showcase the use of energy consumption in specific rooms of a building, directed in different geographical directions. On the other hand, many publications present methods, such as machine learning or AI, for building energy management and prediction of its consumption. These methods have limitations and represent a certain level of uncertainty. In order to compare energy consumption of different rooms, the measurements of particular building-room parameters were collected and analyzed. The obtained results showcase the effect of room location, regarding geographical directions, for the consumption of energy for heating. For south-exposed rooms, due to sun radiation, it is possible to switch heating off completely, and even overheating of 3 °C above the 22 °C temperature set point occurs. The impact of the sun radiation for rooms with a window directed east or west reached about 1 °C and lasts for a few hours before noon for the east, and until late afternoon for the west.


Author(s):  
Nimra Kanwal ◽  
Nuhzat Khan

Buildings are the most important part of development activities, consumed over one-thirds of the global energy. Household used the maximum energy around the world, likewise in Pakistan residential buildings consumed about half of total energy (45.9% per year). The study aims to analyze the impact of building design on climate of Metropolitan City Karachi, Pakistan and to evaluate the change in urbanization patterns and energy consumption in the buildings. To have better understanding of the issues correlations was established amongst population, urbanization patterns, green area, number of buildings (residential and commercial), building design, energy consumption and metrological records (climate change parameters) by collecting the data from the respective departments. With the help of the collected data amount of carbon dioxide was estimated. The results reveled that during last 36 years the urban population of Karachi increased exponentially from 5,208,000 (1981) to 14,737,257 (2017) with increase in urbanized area from 8.35 km2 (1946) to 3,640 km2 (2017) that may led to reduce the green area of the city from 495,000 hectors (1971) to 100,000 hectors (2015). Moreover, the building’s design and numbers are being changed from 21 high-rise buildings (2009) to 344 (2017). It may be concluded that change in temperature pattern and climatic variability of the city may be due to increase in population and change in lifestyle that lead to high energy consumption that is prime source of increased in CO2 emission in the environment of Karachi city, However, Greenhouse Gases (GHG) releases are much lower than the levels reported from metropolitan cities around the world.


2019 ◽  
Vol 17 (1) ◽  
pp. 105-118
Author(s):  
Ana Vukadinovic ◽  
Jasmina Radosavljevic ◽  
Amelija Djordjevic ◽  
Nemanja Petrovic

The increase in energy consumption in building design and construction and the issues related to environmental protection have steered many current researchers toward examining the ways to reduce total CO2 emissions, which resulted in the development of various measures to increase energy efficiency. One measure for more cost-efficient and rational use of energy resources in individual residential buildings is the application of passive solar systems with a sunspace. This paper presents the effects of the shape factor of a residential building with a passive sunspace on the total consumption of heating and cooling energy. The total amount of energy required for building heating and cooling was calculated by means of dynamic modelling using EnergyPlus software. The simulations were run according to the meteorological parameters for the city of Nis. For simulation purposes, models of residential buildings with a passive sunspace and square- and rectangle-shaped floors were designed. The variations between the models include different building shape factor, floor geometry, surface area of the southern fa?ade, and glazing percentage, i.e. window-to-wall ratio (WWR). Examination of the models with WWR=20%, WWR=40%, and WWR=60% revealed that the elongated shape of a building with the aspect ratio of 2.25:1, with the longer side of the fa?ade facing south, is the most favourable in terms of heating energy consumption. For the same WWRs, the elongated shape of a building with the aspect ratio of 1.56:1, with the longer side of the fa?ade facing south, is the most favourable in terms of cooling energy consumption. As WWR increases, so does the amount of energy required to cool the building. The biggest increase in heating energy consumption was observed in buildings with the aspect ratio 1:2.25, with the shorter side facing south.


2018 ◽  
Vol 22 (6 Part A) ◽  
pp. 2355-2365
Author(s):  
Veliborka Bogdanovic ◽  
Dusan Randjelovic ◽  
Miomir Vasov ◽  
Marko Ignjatovic ◽  
Jelena Stevanovic

This paper analyzes the impact of Trombe wall construction on heating and cooling demands of building with form (rectangular single-store building of about one hundred square meters area) which is common for individual residential buildings in the Republic of Serbia. Trombe wall, as a representative of a passive solar design, was installed on the south wall of the building. Model of the building was made in the Google SketchUp software, while the results of energy performance were obtained using EnergyPlus and jEplus. Parameters of thermal comfort and climatic data for the area of city of Belgrade, Republic of Serbia, were taken into account. Coverage of the south fa?ade was varied, as well as the thickness of the thermal mass and orientation. Energy consumption of the object is discussed, based on obtained results of the analysis. According to comparative analysis of the above mentioned models it can be concluded that the application of the Trombe wall structure on south side may lead to savings of 33% on heating, but also the higher energy consumption for cooling. Total energy consumption on an annual basis is reduced by using this system.