A new distributed measurement index for the identification of harmonic distortion and/or unbalance sources based on the IEEE Std. 1459 framework

2019 ◽  
Vol 172 ◽  
pp. 96-104 ◽  
Author(s):  
Alejandro Pérez Vallés ◽  
Patricio Salmerón Revuelta
2020 ◽  
Vol 10 (11) ◽  
pp. 3869 ◽  
Author(s):  
Stanislav Babaev ◽  
Ravi Shankar Singh ◽  
Sjef Cobben ◽  
Vladimir Ćuk ◽  
Allan Downie

This paper focuses on studying the phenomenon of harmonic distortion propagation through distribution networks. This phenomenon is governed by a combination of factors involving the nature of harmonic loads and their dynamic interaction, the influence of background voltage distortion, and harmonic impedance values. The objective of the proposed research includes evaluation of the network response at different nodes to harmonic current injections via utilizing a time-synchronized distributed measurement system. The study is performed in a fully controlled and flexible test network with three medium voltage/low voltage (MV/LV) distribution substations and several managed LV harmonic sources, namely PV inverter, single-phase EV charger and emulated harmonic load with reference current injections. A selection of the results is analyzed and interpretation of the observed phenomena is given with implications that synchronized harmonic measurements can be considered as potential powerful instruments for analyzing power quality disturbances.


2020 ◽  
pp. 85-88 ◽  
Author(s):  
Nadezhda P. Kondratieva

The article describes the results of the study concerning the effect of the voltage level on current harmonic composition in greenhouses irradiators. It is found that its change affects the level of current harmonics of all types of the studied greenhouse irradiators. With decrease of nominal supply voltage by 10 %, the total harmonic distortion THDi decreases by 9 % for emitters equipped with high pressure sodium lamps (HPSL), by 10 % for emitters with electrode-less lamps and by 3 % for LED based emitters. With increase of nominal supply voltage by 10 %, THDi increases by 23 % for lighting devices equipped with HPSL, by 10 % for irradiators with electrode-less lamps and by 3 % for LED based emitters. Therefore, changes of supply voltage cause the least effect on the level of current harmonics of LED based emitters and then the emitters with electrode-less lamps. Change of the level of supply voltage causes the greatest effect on the level of current harmonics of HPSL based irradiators. Mathematical models of dependence of THDi on the level of supply voltage for greenhouse emitters equipped with LED, electrode-less lamps and HPSL lamps were formulated. These mathematical models may be used for calculations of total current when selecting transformers and supply cable lines for greenhouse lighting devices, for design of new or reconstruction of existing irradiation systems of greenhouse facilities, and for calculation of power losses in power supply networks of greenhouse facilities during feasibility studies for energy saving and energy efficiency increasing projects.


2003 ◽  
Vol 1 (01) ◽  
pp. 461-467 ◽  
Author(s):  
I. Zamora ◽  
◽  
I. Albizu ◽  
A.J. Mazón ◽  
K.J. Sagastabeitia ◽  
...  