Investigation on the OH*and CH* chemiluminescence characteristics of single coal particle flames under O2/CO2 atmosphere

2022 ◽  
Vol 225 ◽  
pp. 107059
Author(s):  
Fei Xie ◽  
Runmin Wu ◽  
Juntao Wei ◽  
Xudong Song ◽  
Jinyun Li ◽  
...  
Keyword(s):  
Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1316
Author(s):  
Daniel Mahon ◽  
Gianfranco Claudio ◽  
Philip Eames

To improve the energy efficiency of an industrial process thermochemical energy storage (TCES) can be used to store excess or typically wasted thermal energy for utilisation later. Magnesium carbonate (MgCO3) has a turning temperature of 396 °C, a theoretical potential to store 1387 J/g and is low cost (~GBP 400/1000 kg). Research studies that assess MgCO3 for use as a medium temperature TCES material are lacking, and, given its theoretical potential, research to address this is required. Decomposition (charging) tests and carbonation (discharging) tests at a range of different temperatures and pressures, with selected different gases used during the decomposition tests, were conducted to gain a better understanding of the real potential of MgCO3 for medium temperature TCES. The thermal decomposition (charging) of MgCO3 has been investigated using thermal analysis techniques including simultaneous thermogravimetric analysis and differential scanning calorimetry (TGA/DSC), TGA with attached residual gas analyser (RGA) and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) (up to 650 °C). TGA, DSC and RGA data have been used to quantify the thermal decomposition enthalpy from each MgCO3.xH2O thermal decomposition step and separate the enthalpy from CO2 decomposition and H2O decomposition. Thermal analysis experiments were conducted at different temperatures and pressures (up to 40 bar) in a CO2 atmosphere to investigate the carbonation (discharging) and reversibility of the decarbonation–carbonation reactions for MgCO3. Experimental results have shown that MgCO3.xH2O has a three-step thermal decomposition, with a total decomposition enthalpy of ~1050 J/g under a nitrogen atmosphere. After normalisation the decomposition enthalpy due to CO2 loss equates to 1030–1054 J/g. A CO2 atmosphere is shown to change the thermal decomposition (charging) of MgCO3.xH2O, requiring a higher final temperature of ~630 °C to complete the decarbonation. The charging input power of MgCO3.xH2O was shown to vary from 4 to 8136 W/kg with different isothermal temperatures. The carbonation (discharging) of MgO was found to be problematic at pressures up to 40 bar in a pure CO2 atmosphere. The experimental results presented show MgCO3 has some characteristics that make it a candidate for thermochemical energy storage (high energy storage potential) and other characteristics that are problematic for its use (slow discharge) under the experimental test conditions. This study provides a comprehensive foundation for future research assessing the feasibility of using MgCO3 as a medium temperature TCES material. Future research to determine conditions that improve the carbonation (discharging) process of MgO is required.


Polymer ◽  
2020 ◽  
Vol 206 ◽  
pp. 122912
Author(s):  
Naoya Yanagishima ◽  
Shinji Kanehashi ◽  
Hiromu Saito ◽  
Kenji Ogino ◽  
Takeshi Shimomura

2021 ◽  
Vol 43 (5) ◽  
Author(s):  
Divya K. Unnikrishnan ◽  
Rachapudi V. Sreeharsha ◽  
Attipalli R. Reddy

Author(s):  
Wei Luo ◽  
Yanqiu Chen ◽  
Junhua Liu ◽  
Yue Yang ◽  
Fang Wang ◽  
...  
Keyword(s):  

Author(s):  
Dawei Yan ◽  
Mingyan Gu ◽  
Xianhui He ◽  
Jialun Wang ◽  
Fuling Wang ◽  
...  

2021 ◽  
Vol 9 (4) ◽  
pp. 577-587
Author(s):  
Wei Liu ◽  
Deyao Wu ◽  
Hao Xu ◽  
Xiangyu Chu ◽  
Wei Zhao ◽  
...  

Molecules ◽  
2020 ◽  
Vol 25 (7) ◽  
pp. 1558 ◽  
Author(s):  
George Mogildea ◽  
Marian Mogildea ◽  
Cristina Popa ◽  
Gabriel Chiritoi

This paper focuses on the dissociation of carbon dioxide (CO2) following the absorption processes of microwave radiation by noncontact metal wire (tungsten). Using a microwave plasma generator (MPG) with a single-mode cavity, we conducted an interaction of microwaves with a noncontact electrode in a CO2 atmosphere. High energy levels of electromagnetic radiation are generated in the focal point of the MPG’s cylindrical cavity. The metal wires are vaporized and ionized from this area, subsequently affecting the dissociation of CO2. The CO2 dissociation is highlighted through plasma characterization and carbon monoxide (CO) quantity determination. For plasma characterization, we used an optical emission spectroscopy method (OES), and for CO quantity determination, we used a gas analyzer instrument. Using an MPG in the CO2 atmosphere, we obtained a high electron temperature of the plasma and a strong dissociation of CO2. After 20 s of the interaction between microwaves and noncontact electrodes, the quantity of CO increased from 3 ppm to 1377 ppm (0.13% CO). This method can be used in space applications to dissociate CO2 and refresh the atmosphere of closed spaces.


2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Wen-Zheng Wang ◽  
Yan-Ming Wang ◽  
Guo-Qing Shi

Respirable coal particle generated during underground mining is the main cause for gas-dust explosions and coal workers’ pneumoconiosis (CWP) which needs accurate monitoring especially on its concentration. Focusing on the coal dust pollution in the fully mechanized working face of Huangbaici coalmine, coal particle was sampled for further industrial analysis and FT-IR test to obtain its chemical composition and optical constant. Combined with the simulated spatial distribution of airborne dust, the spectral transmission characteristics of coal dust within wavelengths of 2.5 to 25 μm under different operating conditions were obtained. The simulation results show that the transmittance and aerosol optical depth (AOD) of coal dust are closely linked and obviously influenced by the variation of dust generation source (intensity of dust release, position of coal cutting, and the wetting of the coal seam) and airflow field (wind speed and direction of ventilation). Furthermore, an optical channel of 1260–1280 cm−1(7.937–7.813 μm) which is almost only sensitive to the variation of dust concentration but dull to the diameter change of coal dust was selected to establish the correlation of dust concentration and infrared transmittance. The fitting curve was then applied to retrieve the equivalent dust concentration based on optical information, and the comparison results demonstrate that the estimated pollution level is consistent with field measurement data in engineering practice.


Sign in / Sign up

Export Citation Format

Share Document