Spatial distribution and speciation of sulfur in Ediacaran limestones with μ-XRF imaging and XANES spectroscopy: Implications for diagenetic mobilization of sulfur species

Author(s):  
Fumihiro Matsu'ura ◽  
Ryoichi Nakada ◽  
Tomohiro Usui ◽  
Yusuke Sawaki ◽  
Yuichiro Ueno ◽  
...  
2016 ◽  
Vol 14 (2) ◽  
pp. 82-89 ◽  
Author(s):  
Kuniko Takemoto ◽  
Daiya Bamba ◽  
Masahiro Ogawa ◽  
Toshiaki Ohta

2010 ◽  
Vol 151 (3-4) ◽  
pp. 354-361 ◽  
Author(s):  
Jae-Soon Choi ◽  
William P. Partridge ◽  
Michael J. Lance ◽  
Larry R. Walker ◽  
Josh A. Pihl ◽  
...  

2020 ◽  
Vol 105 (3) ◽  
pp. 375-381
Author(s):  
Brendan A. Anzures ◽  
Stephen W. Parman ◽  
Ralph E. Milliken ◽  
Antonio Lanzirotti ◽  
Matthew Newville

Abstract X-ray absorption near-edge structure (XANES) spectroscopy is a powerful technique to quantitatively investigate sulfur speciation in geologically complex materials such as minerals, glasses, soils, organic compounds, industrial slags, and extraterrestrial materials. This technique allows non-destructive investigation of the coordination chemistry and oxidation state of sulfur species ranging from sulfide (2–oxidation state) to sulfate (6+ oxidation state). Each sulfur species has a unique spectral shape with a characteristic K-edge representing the s → p and d hybridization photoelectron transitions. As such, sulfur speciation is used to measure the oxidation state of samples by comparing the overall XANES spectra to that of reference compounds. Although many S XANES spectral standards exist for terrestrial applications under oxidized conditions, new sulfide standards are needed to investigate reduced (oxygen fugacity, fO2, below IW) silicate systems relevant for studies of extraterrestrial materials and systems. Sulfides found in certain meteorites (e.g., enstatite chondrites and aubrites) and predicted to exist on Mercury, such as CaS (oldhamite), MgS (niningerite), and FeCr2S4 (daubréelite), are stable at fO2 below IW-3 but rapidly oxidize to sulfate and/or produce sulfurous gases under terrestrial surface conditions. XANES spectra of these compounds collected to date have been of variable quality, possibly due to the unstable nature of certain sulfides under typical (e.g., oxidizing) laboratory conditions. A new set of compounds was prepared for this study and their XANES spectra are analyzed for comparison with potential extraterrestrial analogs. S K-edge XANES spectra were collected at Argonne National Lab for FeS (troilite), MnS (alabandite), CaS (oldhamite), MgS (niningerite), Ni1–xS, NiS2, CaSO4 (anhydrite), MgSO4, FeSO4, Fe2(SO4)3, FeCr2S4 (daubréelite), Na2S, Al2S3, Ni7S6, and Ni3S2; the latter five were analyzed for the first time using XANES. These standards expand upon the existing S XANES end-member libraries at a higher spectral resolution (0.25 eV steps) near the S K-edge. Processed spectra, those that have been normalized and “flattened,” are compared to quantify uncertainties due to data processing methods. Future investigations that require well-characterized sulfide standards, such as the ones presented here, may have important implications for understanding sulfur speciation in reduced silicate glasses and minerals with applications for the early Earth, Moon, Mercury, and enstatite chondrites.


RSC Advances ◽  
2018 ◽  
Vol 8 (67) ◽  
pp. 38204-38209 ◽  
Author(s):  
Kazuhisa Isegawa ◽  
Daehyun Kim ◽  
Hiroshi Kondoh

Behavior of sulfur species derived from Nafion in PEFC under oxygen atmosphere was revealed by S-K XANES spectroscopy.


2018 ◽  
Vol 133 ◽  
pp. 891-899 ◽  
Author(s):  
Satoshi Asaoka ◽  
Akira Umehara ◽  
Sosuke Otani ◽  
Naoki Fujii ◽  
Tetsuji Okuda ◽  
...  

Microbiology ◽  
2009 ◽  
Vol 155 (8) ◽  
pp. 2766-2774 ◽  
Author(s):  
Bettina Franz ◽  
Thomas Gehrke ◽  
Henning Lichtenberg ◽  
Josef Hormes ◽  
Christiane Dahl ◽  
...  

Before its uptake and oxidation by purple sulfur bacteria, elemental sulfur probably first has to be mobilized. To obtain more insight into this mobilization process in the phototrophic purple sulfur bacterium Allochromatium vinosum, we used HPLC analysis and X-ray absorption near-edge structure (XANES) spectroscopy for the detection and identification of sulfur compounds in culture supernatants and bacterial cells. We intended to identify soluble sulfur compounds that specifically occur during growth on elemental sulfur, and therefore compared spectra of cultures grown on sulfur with those of cultures grown on sulfide or thiosulfate. While various unexpected oxidized organic sulfur species (sulfones, C–SO2–C, and sulfonates, ) were observed via XANES spectroscopy in the supernatants, we obtained evidence for the presence of monosulfane sulfonic acids inside the bacterial cells by HPLC analysis. The concentrations of the latter compounds showed a tight correlation with the content of intracellular sulfur, reaching their maximum when sulfur began to be oxidized. None of the detected sulfur compounds appeared to be a specific soluble intermediate or product of elemental sulfur mobilization. It therefore seems unlikely that mobilization of elemental sulfur by purple sulfur bacteria involves excretion of soluble sulfur-containing substances that would be able to act on substrate distant from the cells.


Author(s):  
L. D. Jackel

Most production electron beam lithography systems can pattern minimum features a few tenths of a micron across. Linewidth in these systems is usually limited by the quality of the exposing beam and by electron scattering in the resist and substrate. By using a smaller spot along with exposure techniques that minimize scattering and its effects, laboratory e-beam lithography systems can now make features hundredths of a micron wide on standard substrate material. This talk will outline sane of these high- resolution e-beam lithography techniques.We first consider parameters of the exposure process that limit resolution in organic resists. For concreteness suppose that we have a “positive” resist in which exposing electrons break bonds in the resist molecules thus increasing the exposed resist's solubility in a developer. Ihe attainable resolution is obviously limited by the overall width of the exposing beam, but the spatial distribution of the beam intensity, the beam “profile” , also contributes to the resolution. Depending on the local electron dose, more or less resist bonds are broken resulting in slower or faster dissolution in the developer.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
Auclair Gilles ◽  
Benoit Danièle

During these last 10 years, high performance correction procedures have been developed for classical EPMA, and it is nowadays possible to obtain accurate quantitative analysis even for soft X-ray radiations. It is also possible to perform EPMA by adapting this accurate quantitative procedures to unusual applications such as the measurement of the segregation on wide areas in as-cast and sheet steel products.The main objection for analysis of segregation in steel by means of a line-scan mode is that it requires a very heavy sampling plan to make sure that the most significant points are analyzed. Moreover only local chemical information is obtained whereas mechanical properties are also dependant on the volume fraction and the spatial distribution of highly segregated zones. For these reasons we have chosen to systematically acquire X-ray calibrated mappings which give pictures similar to optical micrographs. Although mapping requires lengthy acquisition time there is a corresponding increase in the information given by image anlysis.


Sign in / Sign up

Export Citation Format

Share Document