A comparison of temperature distribution in PEMFC with single-phase water cooling and two-phase HFE-7100 cooling methods by numerical study

2018 ◽  
Vol 43 (29) ◽  
pp. 13406-13419 ◽  
Author(s):  
Eun Jung Choi ◽  
Jin Young Park ◽  
Min Soo Kim
2013 ◽  
Vol 307 ◽  
pp. 215-218
Author(s):  
Te Ba ◽  
Arthur Teck Bin Lim ◽  
Chang Wei Kang

The paper presents the numerical investigation of a radial flow centrifugal pump with 2D curvature blade geometry. The geometry is based on the experimental equipment by Anagostopulos. Single phase (water) flow is modeled with a normal mass flow rate and rotation speed. Pressure distribution and fluid streamlines are evaluated and visualized. An extension of the model to transient flow and two-phase flow simulation has been done to see the effect of impeller rotation and gas entrainment in the centrifugal operation procedure.


2001 ◽  
Author(s):  
G. Hetsroni ◽  
A. Mosyak ◽  
Z. Segal

Abstract Experimental investigation of a heat sink for electronics cooling is performed. The objective is to keep the operating temperature at a relatively low level of about 323–333K, while reducing the undesired temperature variation in both the streamwise and transverse directions. The experimental study is based on systematic temperature, flow and pressure measurements, infrared radiometry and high-speed digital video imaging. The heat sink has parallel triangular microchannels with a base of 250μm. According to the objectives of the present study, Vertrel XF is chosen as the working fluid. Experiments on flow boiling of Vertrel XF in the microchannel heat sink are performed to study the effect of mass velocity and vapor quality on the heat transfer, as well as to compare the two-phase results to a single-phase water flow.


Author(s):  
Mayumi Ouchi ◽  
Yoshiyuki Abe ◽  
Masato Fukagaya ◽  
Takashi Kitagawa ◽  
Haruhiko Ohta ◽  
...  

Energy consumption in data centers has seen a drastic increase in recent years. In data centers, server racks are cooled down in an indirect way by air-conditioning systems installed to cool the entire server room. This air cooling method is inefficient as information technology (IT) equipment is insufficiently cooled down, whereas the room is overcooled. The development of countermeasures for heat generated by IT equipment is one of the urgent tasks to be accomplished. We, therefore, proposed new liquid cooling systems in which IT equipment is cooled down directly and exhaust heat is not radiated into the server room. Three cooling methods have been developed simultaneously. Two of them involve direct cooling; a cooling jacket is directly attached to the heat source (or CPU in this case) and a single-phase heat exchanger or a two-phase heat exchanger is used as the cooling jacket. The other method involves indirect cooling; heat generated by CPU is transported to the outside of the chassis through flat heat pipes and the condensation sections of the heat pipes are cooled down by coolant with liquid manifold. Verification tests have been conducted by using commercial server racks to which these cooling methods are applied while investigating five R&D components that constitute our liquid cooling systems: the single-phase heat exchanger, the two-phase heat exchanger, high performance flat heat pipes, nanofluid technology, and the plug-in connector. As a result, a 44–53% reduction in energy consumption of cooling facilities with the single-phase cooling system and a 42–50% reduction with the flat heat pipe cooling system were realized compared with conventional air cooling system.


2021 ◽  
Vol 2021 ◽  
pp. 1-17
Author(s):  
Moloud Arian Maram ◽  
Hamid Reza Ghafari ◽  
Hassan Ghassemi ◽  
Mahmoud Ghiasi

This paper is presented on the tandem two-dimensional hydrofoils with profiles NACA4412 in single-phase and two-phase flow domains for different submergence depths and different distances in a various angle of attack (AoA). Also, supercavitation is studied at σ = 0.34 by the Zwart cavitation model. Reynolds-averaged Navier–Stokes (RANS) with the shear stress transport (SST) K-ω is employed as a turbulence model in transient analysis of Ansys FLUENT software. The numerical results show that, by increasing depth, the drag coefficient increases for both hydrofoils 1 and 2 as well as the lift coefficient. The drag coefficient of hydrofoil 2 is bigger than hydrofoil 1 for all depths; moreover, it was found that the flow pressure behind the hydrofoil 1 had affected the upper and the lower surface of the hydrofoil 2 at each distance or AoA. These effects are observed in the hydrofoil 2 lift coefficient as well as the flow separation. However, the maximum lift-to-drag ratio is observed at AoA =  8 ° and 3.5c distance. Also, single-phase results reveal that the value of pressure and the hydrodynamic coefficient are very different from the two-phase flow results, due to the elimination of the free surface. So, a two-phase flow domain is recommended for increasing the accuracy of results. In addition, the investigation of supercavitation shows a growth in cavity occurrence on the surface by raising AoA.


Author(s):  
Dae W. Kim ◽  
Emil Rahim ◽  
Avram Bar-Cohen ◽  
Bongtae Han

The thermofluid characteristics of a chip-scale microgap cooler, including single-phase flow of water and FC-72 and flow boiling of FC-72, are explored. Heat transfer and pressure drop results for single phase water are used to validate a detailed numerical model and, together with the convective FC-72 data, establish a baseline for microgap cooler performance. Experimental results for single phase water and FC-72 flowing in 120 μm, 260 μm and 600 μm microgap coolers, 31mm wide by 34mm long, at velocities of 0.1 – 2 m/s are reported. “Pseudo-boiling” driven by dissolved gas and flow boiling of FC-72 are found to provide significant enhancement in heat transfer relative to theoretical single phase values.