Laser triangulation as a fast and reliable method for determining ribbon solid fraction; focus on accuracy, precision, and measurement time

Author(s):  
Tim D. Lillotte ◽  
Paul Bebernik ◽  
Johanna Keck ◽  
Moritz Bommer ◽  
Daniela Schröder ◽  
...  
Author(s):  
Bernhard Rossegger ◽  
Michael Engelmayer ◽  
Andreas Wimmer

Abstract Lube oil emission is thought to have a negative influence on hydrocarbon and particle emissions, autoignition and the life-cycle cost of internal combustion engines. Thus, one of the major goals of combustion engine research and development is to optimize lube oil consumption, for example by optimizing the tribological behavior of the piston group (interaction between piston rings and cylinder liner). This requires the application of a fast and accurate lube oil consumption measurement method. Methods such as gravimetric and volumetric measurement are outdated for R&D applications because of measurement time, absolute accuracy as well as repeatability, however some OEMs are still applying this method. At present, the use of tracer methods for measuring lube oil consumption is considered the most promising in terms of decreasing measurement time and increasing accuracy. For example, sulfur as a tracer is one of the most established methods for measuring lube oil consumption, but previous publications have revealed downsides and future challenges of its use. This publication, however, highlights the challenges of using the stable hydrogen isotope deuterium as a tracer which are still to overcome, in order to become a viable and reliable method for measuring lube oil consumption on internal combustion engines. In the introduction, a novel concept of measuring lube oil consumption with deuterated engine oil and the test bench setup are explained. Following laboratory experiments, test bench runs on a heavy-duty diesel engine and long-term studies on a field engine, three major challenges facing the new approach are identified and potential solutions are proposed. First, the long-term stability of the tracer in the lube oil and potential changes in the physical and chemical properties of the oil due to deuteration are discussed in light of the results of tests on a field engine that uses deuterated engine oil. Second, the hydrogen-deuterium exchange process to mark the oil with the tracer is examined and potential approaches for reducing cost and duration are highlighted. The universal applicability of the deuteration process to several base oil groups is also explained. Finally, the detection of deuterium in the gas of the engine exhaust and potential cross-sensitivities to trace gases as well as other crucial limitations of the detector in analyzing engine exhaust are addressed. The summary presents the requirements for converting the experiments with a deuterium tracer into a reliable method for lube oil consumption measurement providing crucial properties such as high accuracy, short measurement time, effort and ease of use.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2574
Author(s):  
Jona Gladines ◽  
Seppe Sels ◽  
Johan Blom ◽  
Steve Vanlanduit

Shape from focus is an accurate, but relatively time-consuming, 3D profilometry technique (compared to e.g., laser triangulation or fringe projection). This is the case because a large amount of data that needs to be captured and processed to obtain 3D measurements. In this paper, we propose a two-step shape-from-focus measurement approach that can improve the speed with 40%. By using a faster profilometry technique to create a coarse measurement of an unknown target, this coarse measurement can be used to limit the data capture to only the required frames. This method can significantly improve the measurement and processing speed. The method was tested on a 40 mm by 40 mm custom target and resulted in an overall 46% reduction of measurement time. The accuracy of the proposed method was compared against the conventional shape from focus method by comparing both methods with a more accurate reference.


Author(s):  
B. D. Athey ◽  
A. L. Stout ◽  
M. F. Smith ◽  
J. P. Langmore

Although there is general agreement that Inactive chromosome fibers consist of helically packed nucleosomes, the pattern of packing is still undetermined. Only one of the proposed models, the crossed-linker model, predicts a variable diameter dependent on the length of DNA between nucleosomes. Measurements of the fiber diameter of negatively-stained and frozen- hydrated- chromatin from Thyone sperm (87bp linker) and Necturus erythrocytes (48bp linker) have been previously reported from this laboratory. We now introduce a more reliable method of measuring the diameters of electron images of fibrous objects. The procedure uses a modified version of the computer program TOTAL, which takes a two-dimensional projection of the fiber density (represented by the micrograph itself) and projects it down the fiber axis onto one dimension. We illustrate this method using high contrast, in-focus STEM images of TMV and chromatin from Thyone and Necturus. The measured diameters are in quantitative agreement with the expected values for the crossed-linker model for chromatin structure


1987 ◽  
Vol 26 (02) ◽  
pp. 87-92 ◽  
Author(s):  
A. Verbruggen ◽  
C. De Bakker ◽  
A. Vandecruys ◽  
J. Joosten ◽  
A. Nevelsteen ◽  
...  

The action of antithrombotic drugs can be evaluated by measuring the deposition of111In-labelled platelets on peripheral bypass grafts several days after injection. This evaluation can be performed qualitatively (visual interpretation on the daily images) or quantitatively. Four different methods which calculate the ratio of platelet uptake with a reference region are compared: two methods use a gamma camera and two a detector. A blood sample or the region under the sternal angle are used as reference. The daily ratio of the counts, recorded by a gamma camera in a region of interest covering the graft, and the blood radioactivity interpolated from a platelet survival curve appears to be the most reliable method. The information of all the ratios can be combined in a single thrombogenicity index which reflects the daily rise of a linear or exponential regression versus time.


1981 ◽  
Vol 45 (03) ◽  
pp. 204-207 ◽  
Author(s):  
Wolfgang Siess ◽  
Peter Roth ◽  
Peter C Weber

SummaryPlatelets have been implicated in the development of atherosclerotic and thrombotic vascular diseases. Evaluation of platelet aggregation in relation to endogenously formed compounds which affect platelet function may provide information of clinical and pharmacological relevance. We describe a method in which thromboxane B2 (TXB2) formation was analyzed following stimulation of platelet-rich plasma (PRP) with ADP, 1-epinephrine, collagen, and arachidonic acid. In addition, we determined platelet sensitivity to prostacyclin following ADP- and collagen-induced platelet aggregation. The parameters under study were found to depend on the platelet count in PRP, on the type and dose of the aggregating agent used, and on the test time after blood sampling. By standardization of these variables, a reliable method was established which can be used in clinical and pharmacological trials.


2012 ◽  
Vol 3 (6) ◽  
pp. 22-23
Author(s):  
Achalla Naga Valli Kameshwari Sravani ◽  
◽  
Gurneet Kaur ◽  
Shweta Singh ◽  
Mritunjay Kumar Singh
Keyword(s):  

2018 ◽  
Vol 26 (2) ◽  
Author(s):  
Dean A. Forbes

In a recent essay published in this journal, I illustrated the limitations one may encounter when sequencing texts temporally using s-curve analysis. I also introduced seriation, a more reliable method for temporal ordering much used in both archaeology and computational biology. Lacking independently ordered Biblical Hebrew (BH) data to assess the potential power of seriation in the context of diachronic studies, I used classic Middle English data originally compiled by Ellegård. In this addendum, I reintroduce and extend s-curve analysis, applying it to one rather noisy feature of Middle English. My results support Holmstedt’s assertion that s-curve analysis can be a useful diagnostic tool in diachronic studies. Upon quantitative comparison, however, the five-feature seriation results derived in my former paper are found to be seven times more accurate than the single-feature s-curve results presented here. 


Sign in / Sign up

Export Citation Format

Share Document