Numerical analysis of square concrete-filled double skin steel tubular columns with rubberized concrete

Structures ◽  
2021 ◽  
Vol 32 ◽  
pp. 1026-1047
Author(s):  
Pouria Ayough ◽  
Zainah Ibrahim ◽  
N.H. Ramli Sulong ◽  
Po-Chien Hsiao ◽  
Mohamed Elchalakani
2011 ◽  
Vol 368-373 ◽  
pp. 511-514
Author(s):  
Wei Bin Yuan ◽  
Shi Long Ma

An investigation of the octagon-shaped concrete-filled double skin steel tubular columns which used PVC-U pipe to replace the steel tube as inner tube was carried out. In order to study the performances and mechanisms of the components when suffered axial load, ultimate axial bearing capacities of 9 components were tested. The cross-sectional size of the outer steel tube and inner PVC-U pipe and length of the specimen was concerned by the nominal steel ratio and the hollow ratio and slenderness ratio, respectively. The external steel tube and core concrete appeared three and four types of destruction phenomenons, respectively, but the inner PVC-U pipe did not destroy. Finally, experimental results and numerical analysis results were comparied.


Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1434
Author(s):  
Muhammmad Faisal Javed ◽  
Haris Rafiq ◽  
Mohsin Ali Khan ◽  
Fahid Aslam ◽  
Muhammad Ali Musarat ◽  
...  

This experimental study presents concrete-filled double-skin tubular columns and demonstrates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10% strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004).


2018 ◽  
Vol 165 ◽  
pp. 328-339 ◽  
Author(s):  
L. C. O. Souza ◽  
H. A. Souza ◽  
E. F. Rodrigues

Sign in / Sign up

Export Citation Format

Share Document