Myocardial Substrate Characterization by CMR T1 Mapping in Patients With NICM and No LGE Undergoing Catheter Ablation of VT

Author(s):  
Daniele Muser ◽  
Gaetano Nucifora ◽  
Simon A. Castro ◽  
Andres Enriquez ◽  
C. Anwar A. Chahal ◽  
...  
2021 ◽  
Vol 7 (7) ◽  
pp. 841-842
Author(s):  
Donald D. Hegland ◽  
Han W. Kim ◽  
Jonathan P. Piccini

Heart Rhythm ◽  
2014 ◽  
Vol 11 (9) ◽  
pp. 1551-1559 ◽  
Author(s):  
Liang-han Ling ◽  
Alex J.A. McLellan ◽  
Andrew J. Taylor ◽  
Leah M. Iles ◽  
Andris H. Ellims ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
L Fiedler ◽  
F Roithinger ◽  
I Roca ◽  
F Lorgat ◽  
A Roux ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott Background 3D mapping systems are pivotal to identify low voltage areas and to define ablation strategies. In this context, high-density multipolar mapping catheters with varying electrode configurations are used for accurate myocardial substrate definition. High density mapping using a grid shaped catheter allows for use of simultaneous analysis of adjacent orthogonal bipolar signals that may assist in more accurate substrate characterization and ablation strategy decisions. Purpose This was a prospective, multicenter observational study to characterize the utility of electroanatomical mapping with a high density grid-style mapping catheter (HD Grid) in subjects undergoing catheter ablation for persistent atrial fibrillation (PersAF) or ventricular tachycardia (VT) in real-world clinical settings. Methods Mapping was performed with the HD Grid catheter to generate high-density maps of cardiac chambers in order to assess the potential influence of the simultaneous orthogonal bipole configuration on PersAF and VT ablation strategies. Differences in substrate identification between simultaneous orthogonal bipole configuration and standard along-the-spline electrode configuration, and potential effects on ablation strategies were investigated. Results During the study period (January 2019 through April 2020), 367 subjects underwent catheter ablation for PersAF (N = 333, average age 64.1yr, 75% male) or VT (N = 34, average age = 64.3yr, 85.3% male). In total, 494 maps were generated to treat patients undergoing PersAF ablation and 57 to treat patients undergoing VT ablation. Compared to standard along-the-spline configuration, mapping with the simultaneous orthogonal bipole configuration showed differences in 57.8% (178/308) of maps generated, with the greatest difference noticed in surface area of low voltage (62.9%) and location of low voltage (55.6%). In comparisons performed live during the procedure (n = 50), simultaneous orthogonal bipole configuration assisted in identification of ablation targets in 70.0% of cases, changing the ablation strategy compared to that identified with along-the-spline configuration in 34.3%. In comparisons performed retrospectively after the procedure (n = 258), the ablation strategy identified with simultaneous orthogonal bipole configuration differed from along-the-spline configuration in 21.7% of maps. Even compared to a higher-density electrode configuration using all-bipoles rather than along-the-spline bipoles, simultaneous orthogonal bipole configuration identified differences in 57.1% of maps. Conclusion The HD grid catheter combined with simultaneous orthogonal bipole configuration can define myocardial substrate more accurately compared to standard along-the-spline configuration. The difference in substrate identification has potential impact on ablation strategy. Further clinical trials are needed to elucidate the role of orthogonal bipole configuration mapping and improved ablation success rates.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Promporn Suksaranjit ◽  
Brent D Wilson ◽  
Christopher J McGann ◽  
Eugene G Kholmovski ◽  
Imran Haider ◽  
...  

Introduction: Atrial fibrillation (AF) is associated with diffuse myocardial fibrosis as quantified by cardiac magnetic resonance (CMR) using T1 mapping methods. Radiofrequency catheter ablation (RFCA) is evolving, and the role in rhythm control may be ideal for reversing left ventricular (LV) remodeling. Hypothesis: We aimed to study the impact of RFCA on diffuse myocardial fibrosis in AF patients. Methods: We retrospectively collected data from consecutive AF patients who underwent RFCA with modified Look-Locker Inversion recovery T1 mapping sequences on pre/post procedural CMR at 3.0-Tesla. Precontrast T1 relaxation time of the mid-LV short-axis view was used as an index of diffuse LV fibrosis. Primary outcome was the change in diffuse LV fibrosis after RFCA. Results: A total of 11 patients (mean age 67 years, 72% male, 67% paroxysmal AF) were enrolled. Median AF duration was 24.6 months [Interquartile range (IQR): 13.3-45.3)] and median CHA2DS2-VASc was 2 [IQR: 1-3]. Post RFCA CMR was obtained 99.5±18.1 days after the RFCA procedure. Mean precontrast T1 time was significantly lower after RFCA (1182ms vs 1158ms; p=0.0157). Conclusions: Based on our preliminary results, RFCA in AF reduces diffuse myocardial fibrosis and may play a role in reverse LV remodeling.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Azuma ◽  
S Kato ◽  
S Kodama ◽  
K Hayakawa ◽  
M Kagimoto ◽  
...  

Abstract Background The Catheter Ablation versus Standard Conventional Therapy in Patients with Left Ventricular Dysfunction and Atrial Fibrillation (CASTLE-AF) trial has shown that the catheter ablation (CA) for atrial fibrillation (AF) significantly reduced the risk of death and hospitalization for heart failure in patients with non-ischemic dilated cardiomyopathy (NIDCM) and AF (N Engl J Med 2018; 378:417–27). In addition, the Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction (CAMERA-MRI) study demonstrated that the absence of myocardial fibrosis on late gadolinium enhanced (LGE) magnetic resonance imaging (MRI) is associated with improvement of left ventricular systolic function after CA in NIDCM patients with AF (J Am Coll Cardiol 2017; 70:1949–61). Extracellular volume fraction (ECV) by T1 mapping has emerges as a non-invasive mean to quantify diffuse myocardial fibrosis. Purpose The aim of this study was to compare the predictive value of LGE-MRI and ECV by T1 mapping for the prediction of improvement of LVEF after CA in NIDCM patients. Methods A total of twenty-eight patients with NIDCM and AF (age: 67±10 years; 25 (89%) male; LVEF: 34.1±8.8%) were studied. Using a 1.5T MR scanner and 32 channel cardiac coils, cine MRI, LGE-MRI, pre- and post- T1 mapping images of LV wall at mid-ventricular level (modified Look-Locker inversion recovery sequence) were acquired. Myocardial fibrosis on LGE was defined as area with >5SD signal intensity of normal myocardium. ECV from six segments of mid ventricular level were averaged for each patient. All patients underwent CA for AF, and the improvement of LVEF before and after CA were evaluated by echocardiography. Results All patients restored sinus rhythm after CA at the time of echocardiography. The mean LVEF was 34.1±8.8% before CA and 49.1±12.0% after CA (p<0.001), resulting an improvement of 15.0±11.8%. Significant correlation was found between improvements in LVEF and amount of fibrosis on LGE-MRI (r=−0.40, p=0.034), improvement of LVEF and ECV (r=−0.55, p=0.008). In the ROC analysis, ECV had a higher discriminative ability for the improvement of LVEF after CA compared with amount of fibrosis on LGE-MRI (AUC 0.885 vs 0.650) (Figure). Conclusions In NIDCM patients with AF, ECV by T1 mapping had better predictive ability for improvement of LVEF after CA in comparison to LGE-MRI. ROC curves of ECV and LGE-MRI Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document