scholarly journals Directional-TV Algorithm for Image Reconstruction from Limited-Angular-Range Data

2021 ◽  
pp. 102030
Author(s):  
Zheng Zhang ◽  
Buxin Chen ◽  
Dan Xia ◽  
Emil Y. Sidky ◽  
Xiaochuan Pan
2021 ◽  
pp. 1-11
Author(s):  
Buxin Chen ◽  
Zheng Zhang ◽  
Dan Xia ◽  
Emil Y. Sidky ◽  
Xiaochuan Pan

BACKGROUND: Interest exists in dual-energy computed tomography (DECT) imaging with scanning arcs of limited-angular ranges (LARs) for reducing scan time and radiation dose, and for enabling scan configurations of C-arm CT that can avoid possible collision between the rotating X-ray tube/detector and the imaged subject. OBJECTIVE: In this work, we investigate image reconstruction for a type of configurations of practical DECT interest, referred to as the two-orthogonal-arc configuration, in which low- and high-kVp data are collected over two non-overlapping arcs of equal LAR α, ranging from 30° to 90°, separated by 90°. The configuration can readily be implemented, e.g., on CT with dual sources separated by 90° or with the slow-kVp-switching technique. METHODS: The directional-total-variation (DTV) algorithm developed previously for image reconstruction in conventional, single-energy CT is tailored to enable image reconstruction in DECT with two-orthogonal-arc configurations. RESULTS: Performing visual inspection and quantitative analysis of monochromatic images obtained and effective atomic numbers estimated, we observe that the monochromatic images of the DTV algorithm from LAR data are with substantially reduced LAR artifacts, which are observed otherwise in those of existing algorithms, and thus visually correlate reasonably well, in terms of metrics PCC and nMI, with their reference images obtained form full-angular-range data. In addition, effective atomic numbers estimated from LAR data of DECT with two-orthogonal-arc configurations are in reasonable agreement, with relative errors up to ∼  10%, with those estimated from full-angular-range data in DECT. CONCLUSIONS: The results acquired in the work may yield insights into the design of LAR configurations of practical dual-energy application relevance in diagnostic CT or C-arm CT imaging.


2005 ◽  
Vol 4 (2) ◽  
pp. 143-150 ◽  
Author(s):  
Xiaochuan Pan ◽  
Yu Zou ◽  
Dan Xia ◽  
Emil Y. Sidky

The suffciency conditions are derived for exact image reconstruction of a 3D ROI from projections acquired with a reduced helical scan over an angular range considerably smaller than that required by image reconstruction in, e.g., the conventional long object problem, for which the scanned angular range is often more than 2π. ROI reconstruction is investigated by a recently developed filtered-backprojection algorithm that can make use of data acquired with a reduced helical scan. Preliminary numerical studies demonstrate and validate the ROI reconstruction. This work may have significant practical implications because a reduced scan in CT often translates to reduced motion artifacts and reduced radiation dose delivered to the subject.


Author(s):  
Buxin Chen ◽  
Zheng Zhang ◽  
Dan Xia ◽  
Emil Y Sidky ◽  
Xiaochuan Pan

Author(s):  
R. A. Crowther

The reconstruction of a three-dimensional image of a specimen from a set of electron micrographs reduces, under certain assumptions about the imaging process in the microscope, to the mathematical problem of reconstructing a density distribution from a set of its plane projections.In the absence of noise we can formulate a purely geometrical criterion, which, for a general object, fixes the resolution attainable from a given finite number of views in terms of the size of the object. For simplicity we take the ideal case of projections collected by a series of m equally spaced tilts about a single axis.


Author(s):  
Yu Liu

The image obtained in a transmission electron microscope is the two-dimensional projection of a three-dimensional (3D) object. The 3D reconstruction of the object can be calculated from a series of projections by back-projection, but this algorithm assumes that the image is linearly related to a line integral of the object function. However, there are two kinds of contrast in electron microscopy, scattering and phase contrast, of which only the latter is linear with the optical density (OD) in the micrograph. Therefore the OD can be used as a measure of the projection only for thin specimens where phase contrast dominates the image. For thick specimens, where scattering contrast predominates, an exponential absorption law holds, and a logarithm of OD must be used. However, for large thicknesses, the simple exponential law might break down due to multiple and inelastic scattering.


Author(s):  
J.D. Geller ◽  
C.R. Herrington

The minimum magnification for which an image can be acquired is determined by the design and implementation of the electron optical column and the scanning and display electronics. It is also a function of the working distance and, possibly, the accelerating voltage. For secondary and backscattered electron images there are usually no other limiting factors. However, for x-ray maps there are further considerations. The energy-dispersive x-ray spectrometers (EDS) have a much larger solid angle of detection that for WDS. They also do not suffer from Bragg’s Law focusing effects which limit the angular range and focusing distance from the diffracting crystal. In practical terms EDS maps can be acquired at the lowest magnification of the SEM, assuming the collimator does not cutoff the x-ray signal. For WDS the focusing properties of the crystal limits the angular range of acceptance of the incident x-radiation. The range is dependent upon the 2d spacing of the crystal, with the acceptance angle increasing with 2d spacing. The natural line width of the x-ray also plays a role. For the metal layered crystals used to diffract soft x-rays, such as Be - O, the minimum magnification is approximately 100X. In the worst case, for the LEF crystal which diffracts Ti - Zn, ˜1000X is the minimum.