The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections

PM&R ◽  
2016 ◽  
Vol 8 (8) ◽  
pp. 767-772 ◽  
Author(s):  
Daniel Cushman ◽  
Alexandra Flis ◽  
Ben Jensen ◽  
Zachary McCormick
2016 ◽  
Vol 16 (7) ◽  
pp. 876-883 ◽  
Author(s):  
Daniel Cushman ◽  
Ryan Mattie ◽  
Bradley Curtis ◽  
Alexandra Flis ◽  
Zachary L. McCormick

2017 ◽  
Vol 42 ◽  
pp. 19-24 ◽  
Author(s):  
Ryan Mattie ◽  
Zachary L. McCormick ◽  
Benjamin Fogg ◽  
Daniel M. Cushman

2021 ◽  
pp. 197140092199896
Author(s):  
Christin A Tiegs-Heiden ◽  
Naveen S Murthy ◽  
Jennifer R Geske ◽  
Felix E Diehn ◽  
Vance T Lehman ◽  
...  

PurposeUnderstanding all factors that may impact radiation dose and procedural time is crucial to safe and efficient image-guided interventions, such as fluoroscopically guided sacroiliac (SI) joint injections. The purpose of this study was to evaluate the effect of flow pattern (intra- vs. periarticular), patient age, and body mass index (BMI) on radiation dose and fluoroscopy time.MethodsA total of 134 SI joint injections were reviewed. Injectate flow pattern, age, and BMI were analyzed in respect to fluoroscopy time (minutes), radiation dose (kerma area product (KAP); µGy m2), and estimated skin dose (mGy).ResultsBMI did not affect fluoroscopy time, but increased BMI resulted in significantly higher skin and fluoroscopy doses ( p < 0.001). There was no association between fluoroscopy time and flow pattern. Higher skin dose was associated with intraarticular flow ( p = 0.0086), and higher KAP was associated with periarticular flow ( p = 0.0128). However, the odds ratios were close to 1. There was no significant difference between fluoroscopy time or dose based on patient age.ConclusionIncreased BMI had the largest impact on procedural radiation dose and skin dose. Flow pattern also showed a statistically significant association with radiation dose and skin dose, but the clinical difference was small. Proceduralists should be aware that BMI has the greatest impact on fluoroscopy dose and skin dose during SI joint injections compared to other factors.


PM&R ◽  
2016 ◽  
Vol 8 (9) ◽  
pp. 876-882 ◽  
Author(s):  
Daniel M. Cushman ◽  
Ryan Mattie ◽  
Nathan D. Clements ◽  
Zachary L. McCormick

2018 ◽  
Vol 2 (1) ◽  
Author(s):  
Siobhan O’Neill ◽  
Richard G. Kavanagh ◽  
Brian W. Carey ◽  
Niamh Moore ◽  
Michael Maher ◽  
...  

Author(s):  
Ryan D. Madder ◽  
Stacie VanOosterhout ◽  
Abbey Mulder ◽  
Taylor Ten Brock ◽  
Austin T. Clarey ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document