scholarly journals Experimental study on the magnetic permeability of inclusion filled soft polymeric composite for soft-core transformer applications

2021 ◽  
pp. 107430
Author(s):  
Xiaocheng Hu ◽  
Zipeng Liang ◽  
Qiyang Li ◽  
Sideng Hu ◽  
Shaoxing Qu
2004 ◽  
Vol 6 (3) ◽  
pp. 239-261 ◽  
Author(s):  
Vladimir S. Sokolinsky ◽  
Hubertus F. Von Bremen ◽  
J. André Lavoie ◽  
Steven R. Nutt

2010 ◽  
Vol 41 (5) ◽  
pp. 414-421 ◽  
Author(s):  
Mandar Kulkarni ◽  
David Carnahan ◽  
Kapil Kulkarni ◽  
Dong Qian ◽  
Jandro L. Abot

Author(s):  
Sergey Gango ◽  
Konstantin Gusev ◽  
Evgeniy Ilin ◽  
Mikhail Predtechensky ◽  
Vladimir Solovyev ◽  
...  

Experimental study of single-wall carbon nabotubes (CNT) effect on the electrical properties of polymeric composite materials based on epoxy matrix has been carried out. Direct-current (DC) as well as alternating-current (AC) electrical conductivity of nanocomposites with different CNT concentrations have been investigated in the temperature interval from 293 K to 373 K. Measurements of Seebeck coefficient confirm n-type conductivity of composite with CNTs. Percolation threshold of the composite material under study has been estimated. It has been found that addition of single-wall CNT at low concentration causes hysteresis of current-voltage characteristics and the temperature dependences of electrical conductivity as well as its anisotropy in the samples under study. No noticeable frequency dependence of the AC electrical conductivity has been found in the frequency range from 100 Hz to 300 kHz.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


Sign in / Sign up

Export Citation Format

Share Document