Heat transfer simulation, analysis and performance study of single U-tube borehole heat exchanger

2020 ◽  
Vol 145 ◽  
pp. 1430-1448 ◽  
Author(s):  
Esa Dube Kerme ◽  
Alan S. Fung
Polymers ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1175
Author(s):  
Tereza Kroulíková ◽  
Tereza Kůdelová ◽  
Erik Bartuli ◽  
Jan Vančura ◽  
Ilya Astrouski

A novel heat exchanger for automotive applications developed by the Heat Transfer and Fluid Flow Laboratory at the Brno University of Technology, Czech Republic, is compared with a conventional commercially available metal radiator. The heat transfer surface of this heat exchanger is composed of polymeric hollow fibers made from polyamide 612 by DuPont (Zytel LC6159). The cross-section of the polymeric radiator is identical to the aluminum radiator (louvered fins on flat tubes) in a Skoda Octavia and measures 720 × 480 mm. The goal of the study is to compare the functionality and performance parameters of both radiators based on the results of tests in a calibrated air wind tunnel. During testing, both heat exchangers were tested in conventional conditions used for car radiators with different air flow and coolant (50% ethylene glycol) rates. The polymeric hollow fiber heat exchanger demonstrated about 20% higher thermal performance for the same air flow. The efficiency of the polymeric radiator was in the range 80–93% and the efficiency of the aluminum radiator was in the range 64–84%. The polymeric radiator is 30% lighter than its conventional metal competitor. Both tested radiators had very similar pressure loss on the liquid side, but the polymeric radiator featured higher air pressure loss.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


2018 ◽  
Vol 225 ◽  
pp. 01023
Author(s):  
T.M. Yusof ◽  
M.F. Basrawi ◽  
A. Shahrani ◽  
H. Ibrahim

Ground heat exchanger is an exciting technique to reduce energy consumption in building especially in hot climate countries. Implementation of GHE for commercial unit in Malaysia is almost none in record. Thus, performance study of the GHE in Malaysia is crucial to be conducted either experimentally or numerically. Therefore, this paper presents the performance of GHE in term of effectiveness, outlet temperature and rate of heat transfer based on mathematical model. The model is developed based on cross flow heat exchanger with one fluid unmixed. There are two variable parameter used in the analysis which is effectiveness and flowrate of the air for 25 meter length of a PVC pipe. Three effectiveness values which is 0.8, 0.9 and 0.99 have been analysed in this study. Meanwhile, flowrate of air is ranging from 0.02 to 0.2 kg/s. Results show that flowrate at 0.02 kg/s gives great temperature reduction in the pipe compared with higher flowrate. However, flowrate of 0.2 kg/s produces higher cooling potential. Characteristic of the GHE for the rate of heat transfer with 80, 90 and 99 percent effectiveness also have been developed and it has been found that effectiveness of 0.9 provide good combination between flowrate and the rate of heat transfer for 25 meter length of the pipe


Entropy ◽  
2020 ◽  
Vol 22 (1) ◽  
pp. 86
Author(s):  
Guillermo Efren Ovando-Chacon ◽  
Sandy Luz Ovando-Chacon ◽  
Abelardo Rodriguez-Leon ◽  
Mario Diaz-Gonzalez ◽  
Jorge Arturo Hernandez-Zarate ◽  
...  

Heat exchangers play an important role in different industrial processes; therefore, it is important to characterize these devices to improve their efficiency by guaranteeing the efficient use of energy. In this study, we carry out a numerical analysis of flow dynamics, heat transfer, and entropy generation inside a heat exchanger; an aqueous medium used for oil extraction flows through the exchanger. Hot water flows on the shell side; nanoparticles have been added to the water in order to improve heat transfer toward the cold aqueous medium flowing on the tube side. The aqueous medium must reach a certain temperature in order to obtain its oil extraction properties. The analysis is performed for different Richardson numbers (Ri = 0.1–10), nanofluid volume fractions (φ = 0.00–0.06), and heat exchanger heights (H = 0.6–1.0). Results are presented in terms of Nusselt number, total entropy generation, Bejan number, and performance evaluation criterion. Results showed that heat exchanger performance increases with the increase in Ri when Ri > 1 and when reducing H.


2020 ◽  
Vol 12 (18) ◽  
pp. 7345
Author(s):  
Linlin Zhang ◽  
Zhonghua Shi ◽  
Tianhao Yuan

In this paper, a dynamic heat transfer model for the vertical double U-tube borehole heat exchanger (BHE) was developed to comprehensively address the coupled heat transfer between the in-tube fluid and the soil with groundwater advection. A new concept of the heat transfer effectiveness was also proposed to evaluate the BHE heat exchange performance together with the index of the heat transfer rate. The moving finite line heat source model was selected for heat transfer outside the borehole and the steady-state model for inside the borehole. The data obtained in an on-site thermal response test were used to validate the physical model of the BHE. Then, the effects of soil type, groundwater advection velocity, inlet water flow rate, and temperature on the outlet water temperature of BHE were explored. Results show that ignoring the effects of groundwater advection in sand gravel may lead to deviation in the heat transfer rate of up to 38.9% of the ground loop design. The groundwater advection fosters the heat transfer of BHE. An increase in advection velocity may also help to shorten the time which takes the surrounding soil to reach a stable temperature. The mass flow rate of the inlet water to the BHE should be more than 0.5 kg·s−1 but should not exceed a certain upper limit under the practical engineering applications with common scale BHE. The efficiency of the heat transfer of the double U-tube BHE was determined jointly by factors such as the soil’s physical properties and the groundwater advection velocity.


Sign in / Sign up

Export Citation Format

Share Document