A Weak Shear Stress Microfluidic Device based on Viscoelastic Stagnant Region (VSR) for Biosensitive Particle Capture

Talanta ◽  
2021 ◽  
pp. 122550
Author(s):  
Yuwen Lu ◽  
Wei Tan ◽  
Xin Shi ◽  
Mingwei Liu ◽  
Guorui Zhu
Soft Matter ◽  
2016 ◽  
Vol 12 (23) ◽  
pp. 5072-5076 ◽  
Author(s):  
Flurin Sturzenegger ◽  
Tom Robinson ◽  
David Hess ◽  
Petra S. Dittrich

2012 ◽  
Vol 6 (1) ◽  
pp. 014107 ◽  
Author(s):  
Peter Rupprecht ◽  
Laurent Golé ◽  
Jean-Paul Rieu ◽  
Cyrille Vézy ◽  
Rosaria Ferrigno ◽  
...  

Lab on a Chip ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 4373-4390
Author(s):  
Utku M. Sonmez ◽  
Ya-Wen Cheng ◽  
Simon C. Watkins ◽  
Beth L. Roman ◽  
Lance A. Davidson

Endothelial cell polarization and orientation analysis using a novel microfluidic device that can simultaneously generate multiple levels of shear stress and shear stress gradients for systematic mechanobiology studies under flow.


Author(s):  
Fei Liu ◽  
Tingting Chen ◽  
Xudong Zhang ◽  
Fang Li ◽  
Ioana Voiculescu

Measuring water toxicity is a lengthy process, and rapid analytical methods are limited. A complementary approach is to measure water toxicity on live cells via electric cell-substrate impedance sensing (ECIS) using a field portable device. This paper presents a study of the longevity of bovine aortic endothelial cell (BAECs VEC Technologies, Rensselaer, NY) by integrating a microfluidic device onto the ECIS sensors. This microfluidic chamber with a network of tree-like perfusion microfluidic channels for cell media delivery to the culturing chamber was fabricated from a biocompatible polymer and tested for longevity studies. This perfusion microchannels were designed as a symmetric arbor with binary splitting to provide equal flow in all the perfusion channels. The microdimensions of the perfusion channels provide high flow resistance, thus carrying low flow rates for a given head pressure and generating low shear stress to the cells during the long-time cell attachment and proliferation period. With such a microfluidic device, cell media can be automatically and evenly perfused into the culturing chamber and no significant shear stress produced by media perfusion was observed. During the longevity study, the BAECs were able to survive in good health for longer than one month. Toxicity tests to study the BAECs responsiveness to health-threatening concentrations of ammonia using the microfluidic ECIS sensor will be also presented. Using impedance spectroscopy technique we demonstrated the BAECs can rapidly respond to ammonia concentrations between the military exposure guideline of 2mM and human lethal concentration of 55mM. The BAECs monolayer represent the most important component of a biosensor for testing water toxicity in the field. This research concluded that the BAECs could resist at least 34 days on the microfluidic chip and demonstrate high values of cell membrane impedance during long period of time.


2014 ◽  
Vol 9 (1) ◽  
pp. JBSE0006-JBSE0006
Author(s):  
Emilie WEIBULL ◽  
Shunsuke MATSUI ◽  
Helene ANDERSSON SVAHN ◽  
Toshiro OHASHI

PLoS ONE ◽  
2021 ◽  
Vol 16 (1) ◽  
pp. e0245536
Author(s):  
Alessandra Marrella ◽  
Arianna Fedi ◽  
Gabriele Varani ◽  
Ivan Vaccari ◽  
Marco Fato ◽  
...  

Metastasis represents a dynamic succession of events involving tumor cells which disseminate through the organism via the bloodstream. Circulating tumor cells (CTCs) can flow the bloodstream as single cells or as multicellular aggregates (clusters), which present a different potential to metastasize. The effects of the bloodstream-related physical constraints, such as hemodynamic wall shear stress (WSS), on CTC clusters are still unclear. Therefore, we developed, upon theoretical and CFD modeling, a new multichannel microfluidic device able to simultaneously reproduce different WSS characterizing the human circulatory system, where to analyze the correlation between SS and CTC clusters behavior. Three physiological WSS levels (i.e. 2, 5, 20 dyn/cm2) were generated, reproducing values typical of capillaries, veins and arteries. As first validation, triple-negative breast cancer cells (MDA-MB-231) were injected as single CTCs showing that higher values of WSS are correlated with a decreased viability. Next, the SS-mediated disaggregation of CTC clusters was computationally investigated in a vessels-mimicking domain. Finally, CTC clusters were injected within the three different circuits and subjected to the three different WSS, revealing that increasing WSS levels are associated with a raising clusters disaggregation after 6 hours of circulation. These results suggest that our device may represent a valid in vitro tool to carry out systematic studies on the biological significance of blood flow mechanical forces and eventually to promote new strategies for anticancer therapy.


Sign in / Sign up

Export Citation Format

Share Document