Running condition and material response fretting maps of incoloy 800 steam generator tubes against AISI 304L pads in air and room temperature

2019 ◽  
Vol 135 ◽  
pp. 408-420 ◽  
Author(s):  
S.R. Soria ◽  
A. Tolley ◽  
A. Yawny
Author(s):  
Sandra Pagan ◽  
Xinjian Duan ◽  
Michael J. Kozluk ◽  
Brian Mills ◽  
Guylaine Goszczynski

Canadian nuclear standard CSA N285.4 requires the periodic metallurgical examination of removed ex-service steam generator tubes. This paper describes the practices used for the characterization and structural integrity tests of ex-service steam generator tubes at Ontario Power Generation (OPG). It shows that there is no degradation in mechanical properties of Monel 400 tubes after 7 to 18 Effective Full Power Years (EFPY) of operation and Incoloy 800 tubes after more than 10 EFPY of operation.


2015 ◽  
Vol 138 (2) ◽  
Author(s):  
Ki Hyeon Eom ◽  
Jin Weon Kim ◽  
Yun Jae Kim ◽  
Jong Sung Kim

This study investigates the interaction effect of multiple-axial part-through-wall (PTW) flaws on the failure behavior of Alloy 690TT steam generator (SG) tubes. Burst tests of tubes with single and multiple flaws were conducted at room temperature (RT). The flaws were made by the electrodischarge machining (EDM) method on the outer surface of the specimens. Six different configurations of multiple flaws were considered to see the interaction effect; two and three collinear, two and three parallel, and two and three nonaligned flaws. In all cases, an axial flaw with a constant depth of 50% wall-thickness was considered, and the following variables were systematically varied; the axial and/or circumferential separating ligament lengths between flaws, the flaw length, and the number of flaws. Effects of these variables on the failure pressure and failure mode were investigated based on experimental data. The effects of separating ligament lengths and flaw lengths on the failure pressure were dependent on the type of flaw configuration. For collinear and nonaligned flaws, the decrease in failure pressure by the interaction of multiple flaws became significant as the number of flaws increased. The failure mode of multiple flaws was strongly dependent on the length of the flaws.


2008 ◽  
Vol 59 (9) ◽  
Author(s):  
Dumitra Lucan ◽  
Manuela Fulger ◽  
Gheorghita Jinescu

The Steam Generators (SG), equipment that ensures the connection between the primary and secondary circuits, creates several safety problems during operation, mainly due to corrosion and mechanical damages. To provide information about the corrosion behaviour of the structural materials from CANDU SG under normal and abnormal conditions of operation and to identify the failure types produced by the corrosion were performed corrosion experiments consisting in chemical accelerated tests, static autoclaving and electrochemical methods. The gravimetric method, optical metallographic microscopy, XRD and EDS analysis, as well as electrochemical measurements have been used to evaluate the corrosion behavior of the steam generator tubes material (Incoloy-800).


Author(s):  
Mitch Hokazono ◽  
Clayton T. Smith

Integral light-water reactor designs propose the use of steam generators located within the reactor vessel. Steam generator tubes in these designs must withstand external pressure loadings to prevent buckling, which is affected by material strength, fabrication techniques, chemical environment and tube geometry. Experience with fired tube boilers has shown that buckling in boiler tubes is greatly alleviated by controlling ovality in bends when the tubes are fabricated. Light water reactor steam generator pressures will not cause a buckling problem in steam generators with reasonable fabrication limits on tube ovality and wall thinning. Utilizing existing Code rules, there is a significant design margin, even for the maximum differential pressure case. With reasonable bend design and fabrication limits the helical steam generator thermodynamic advantages can be realized without a buckling concern. This paper describes a theoretical methodology for determining allowable external pressure for steam generator tubes subject to tube ovality based on ASME Section III Code Case N-759-2 rules. A parametric study of the results of this methodology applied to an elliptical cross section with varying wall thicknesses, tube diameters, and ovality values is also presented.


2006 ◽  
Vol 321-323 ◽  
pp. 451-454
Author(s):  
Joo Young Yoo ◽  
Sung Jin Song ◽  
Chang Hwan Kim ◽  
Hee Jun Jung ◽  
Young Hwan Choi ◽  
...  

In the present study, the synthetic signals from the combo tube are simulated by using commercial electromagnetic numerical analysis software which has been developed based on a volume integral method. A comparison of the simulated signals to the experiments is made for the verification of accuracy, and then evaluation of five deliberated single circumferential indication signals is performed to explore a possibility of using a numerical simulation as a practical calibration tool. The good agreement between the evaluation results for two cases (calibration done by experiments and calibration made by simulation) demonstrates such a high possibility.


Sign in / Sign up

Export Citation Format

Share Document