Immune efficacy of a candidate porcine reproductive and respiratory syndrome vaccine rHN-NP49 administered by a Needle-free intradermal delivery system in comparison with intramuscular injection

Vaccine ◽  
2021 ◽  
Author(s):  
Yifeng Jiang ◽  
Xianbin Li ◽  
Lingxue Yu ◽  
Wu Tong ◽  
Pengfei Chen ◽  
...  
2009 ◽  
Vol 16 (5) ◽  
pp. 719-725 ◽  
Author(s):  
Joanne Huang ◽  
Ajit J. D'Souza ◽  
Jason B. Alarcon ◽  
John A. Mikszta ◽  
Brandi M. Ford ◽  
...  

ABSTRACT The potential use of Yersinia pestis as a bioterror agent is a great concern. Development of a stable powder vaccine against Y. pestis and administration of the vaccine by minimally invasive methods could provide an alternative to the traditional liquid formulation and intramuscular injection. We evaluated a spray-freeze-dried powder vaccine containing a recombinant F1-V fusion protein of Y. pestis for vaccination against plaque in a mouse model. Mice were immunized with reconstituted spray-freeze-dried F1-V powder via intramuscular injection, microneedle-based intradermal delivery, or noninvasive intranasal administration. By intramuscular injection, the reconstituted powder induced serum antibody responses and provided protection against lethal subcutaneous challenge with 1,000 50% lethal doses of Y. pestis at levels equivalent to those elicited by unprocessed liquid formulations (70 to 90% protection). The feasibility of intradermal and intranasal delivery of reconstituted powder F1-V vaccine was also demonstrated. Overall, microneedle-based intradermal delivery was shown to be similar in efficacy to intramuscular injection, while intranasal administration required an extra dose of vaccine to achieve similar protection. In addition, the results suggest that seroconversion against F1 may be a better predictor of protection against Y. pestis challenge than seroconversion against either F1-V or V. In summary, we demonstrate the preclinical feasibility of using a reconstituted powder F1-V formulation and microneedle-based intradermal delivery to provide protective immunity against plague in a mouse model. Intranasal delivery, while feasible, was less effective than injection in this study. The potential use of these alternative delivery methods and a powder vaccine formulation may result in substantial health and economic benefits.


2006 ◽  
Vol 175 (4S) ◽  
pp. 323-324 ◽  
Author(s):  
Joseph Dall'era ◽  
Sweaty Koul ◽  
Jesse Mills ◽  
Jeremy Myers ◽  
Randall B. Meacham ◽  
...  

VASA ◽  
2017 ◽  
Vol 46 (6) ◽  
pp. 452-461 ◽  
Author(s):  
Klaus Amendt ◽  
Ulrich Beschorner ◽  
Matthias Waliszewski ◽  
Martin Sigl ◽  
Ralf Langhoff ◽  
...  

Abstract. Background: The purpose of this observational study is to report the six-month clinical outcomes with a new multiple stent delivery system in patients with femoro-popliteal lesions. Patients and methods: The LOCOMOTIVE study is an observational multicentre study with a primary endpoint target lesion revascularization (TLR) rate at six months. Femoro-popliteal lesions were prepared with uncoated and/or paclitaxel-coated peripheral balloon catheters. When flow limiting dissections, elastic recoil or recoil due to calcification required stenting, up to six short stents per delivery device, each 13 mm in length, were implanted. Sonographic follow-ups and clinical assessments were scheduled at six months. Results: For this first analysis, a total of 75 patients 72.9 ± 9.2 years of age were enrolled. The majority of the 176 individually treated lesions were in the superficial femoral artery (76.2 %, 134/176) whereas the rate of TASC C/D amounted to 51.1 % (90/176). The total lesion length was 14.5 ± 9.0 cm with reference vessel diameters of 5.6 ± 0.7 mm. Overall 47 ± 18 % of lesion lengths could be saved from stenting. At six months, the patency was 90.7 % (68/75) and all-cause TLR rates were 5.3 % (4/75) in the overall cohort. Conclusions: The first clinical experience at six months suggests that the MSDS strategy was safe and effective to treat femoro-popliteal lesions of considerable length (14.5 ± 9.0 cm). Almost half of the lesion length could be saved from stenting while patency was high and TLR rates were acceptably low.


1993 ◽  
Vol 48 (3) ◽  
pp. 270-276 ◽  
Author(s):  
Jeff Bingaman ◽  
Robert G. Frank ◽  
Carrie L. Billy

Sign in / Sign up

Export Citation Format

Share Document