scholarly journals Dietary flavonoids and flavonoid-rich foods: validity and reproducibility of FFQ-derived intake estimates

2020 ◽  
Vol 23 (18) ◽  
pp. 3295-3303
Author(s):  
Yiyang Yue ◽  
Joshua Petimar ◽  
Walter C Willett ◽  
Stephanie A Smith-Warner ◽  
Changzheng Yuan ◽  
...  

AbstractObjective:To evaluate the validity and reproducibility of a 152-item semi-quantitative FFQ (SFFQ) for estimating flavonoid intakes.Design:Over a 1-year period, participants completed two SFFQ and two weighed 7-d dietary records (7DDR). Flavonoid intakes from the SFFQ were estimated separately using Harvard (SFFQHarvard) and Phenol-Explorer (SFFQPE) food composition databases. 7DDR flavonoid intakes were derived using the Phenol-Explorer database (7DDRPE). Validity was assessed using Spearman’s rank correlation coefficients deattenuated for random measurement error (rs), and reproducibility was assessed using rank intraclass correlation coefficients.Setting:This validation study included primarily participants from two large observational cohort studies.Participants:Six hundred forty-one men and 724 women.Results:When compared with two 7DDRPE, the validity of total flavonoid intake assessed by SFFQPE was high for both men and women (rs = 0·77 and rs = 0·74, respectively). The rs for flavonoid subclasses ranged from 0·47 for flavones to 0·78 for anthocyanins in men and from 0·46 for flavonols to 0·77 for anthocyanins in women. We observed similarly moderate (0·4–0·7) to high (≥0·7) validity when using SFFQHarvard estimates, except for flavonesHarvard (rs = 0·25 for men and rs = 0·19 for women). The SFFQ demonstrated high reproducibility for total flavonoid and flavonoid subclass intake estimates when using either food composition database. The intraclass correlation coefficients ranged from 0·69 (flavonolsPE) to 0·80 (proanthocyanidinsPE) in men and from 0·67 (flavonolsPE) to 0·77 (flavan-3-ol monomersHarvard) in women.Conclusions:SFFQ-derived intakes of total flavonoids and flavonoid subclasses (except for flavones) are valid and reproducible for both men and women.

2018 ◽  
Vol 62 (9) ◽  
pp. 1159-1170 ◽  
Author(s):  
Aude Lacourt ◽  
France Labrèche ◽  
Mark S Goldberg ◽  
Jack Siemiatycki ◽  
Jérôme Lavoué

Abstract Objectives To estimate the level of agreement and identify notable differences in occupational exposures (agents) between men and women from retrospective assessments by expert coders. Methods Lifetime occupational histories of 1657 men and 2073 women from two case–control studies, were translated into exposure estimates to 243 agents, from data on 13882 jobs. Exposure estimates were summarized as proportions and frequency-weighted intensity of exposure for 59 occupational codes by sex. Agreement between metrics of exposure in men’s and women’s jobs was determined with intraclass correlation coefficients (ICC) and weighted Kappa coefficients, using as unit of analysis (‘cell’) a combination of occupational code and occupational agent. ‘Notable’ differences between men and women were identified for each cell, according to a Bayesian hierarchical model for both proportion and frequency-weighted intensity of exposure. Results For cells common to both men and women, the ICC for continuous probability of exposure was 0.84 (95% CI: 0.83–0.84) and 7.4% of cells showed notable differences with jobs held by men being more often exposed. A weighted kappa of 0.67 (95% CI: 0.61–0.73) was calculated for intensity of exposure, and an ICC of 0.67 (95% CI: 0.62–0.71) for frequency-weighted intensity of exposure, with a tendency of higher values of exposure metrics in jobs held by men. Conclusions Exposures were generally in agreement between men and women. Some notable differences were identified, most of them explained by differential sub-occupations or industries or dissimilar reported tasks within the studied occupations.


2015 ◽  
Vol 50 (4) ◽  
pp. 392-399 ◽  
Author(s):  
Enda Whyte ◽  
Aoife Burke ◽  
Elaine White ◽  
Kieran Moran

Context Deficits in dynamic postural control predict lower limb injury. Differing fatiguing protocols negatively affect dynamic postural control. The effect of high-intensity, intermittent exercise on dynamic postural control has not been investigated. Objective To investigate the effect of a high-intensity, intermittent exercise protocol (HIIP) on the dynamic postural control of men and women as measured by the Star Excursion Balance Test (SEBT). Design Descriptive laboratory study. Setting University gymnasium. Patients or Other Participants Twenty male (age = 20.83 ± 1.50 years, height = 179.24 ± 7.94 cm, mass = 77.67 ± 10.82 kg) and 20 female (age = 20.45 ± 1.34 years, height = 166.08 ± 5.83 cm, mass = 63.02 ± 6.67 kg) athletes. Intervention(s) We recorded SEBT measurements at baseline, pre-HIIP, and post-HIIP. The HIIP consisted of 4 repetitions of 10-m forward sprinting with a 90° change of direction and then backward sprinting for 5 m, 2 repetitions of 2-legged jumping over 5 hurdles, 2 repetitions of high-knee side stepping over 5 hurdles, and 4 repetitions of lateral 5-m shuffles. Participants rested for 30 seconds before repeating the circuit until they reported a score of 18 on the Borg rating of perceived exertion scale. Main Outcome Measure(s) A mixed between- and within–subjects analysis of variance was conducted to assess time (pre-HIIP, post-HIIP) × sex interaction effects. Subsequent investigations assessed the main effect of time and sex on normalized maximal SEBT scores. We used intraclass correlation coefficients to determine the test-retest reliability of the SEBT and paired-samples t tests to assess the HIIP effect on circuit times. Results We found a time × sex effect (F8,69 = 3.5; P range, <.001–.04; η2 range, 0.057–0.219), with women less negatively affected. We also noted a main effect for time, with worse normalized maximal SEBT scores postfatigue (F8,69 = 22.39; P < .001; η2 range, 0.324–0.695), and for sex, as women scored better in 7 SEBT directions (F8,69 = 0.84; P range, <.001–008; η2 range, 0.088–0.381). The intraclass correlation coefficients demonstrated high (0.77–0.99) test-retest repeatability. Paired-samples t tests demonstrated increases in circuit time post-HIIP (P < .001). Conclusions The HIIP-induced fatigue negatively affected normalized maximal SEBT scores. Women had better scores than men and were affected less negatively by HIIP-induced fatigue.


2015 ◽  
Vol 95 (1) ◽  
pp. 103-108 ◽  
Author(s):  
Stephen J. Page ◽  
Erinn Hade ◽  
Andrew Persch

Background There remains a need for a quickly administered, stroke-specific, bedside measure of active wrist and finger movement for the expanding stroke population. The wrist stability and hand mobility scales of the upper extremity Fugl-Meyer Assessment (w/h UE FM) constitute a valid, reliable measure of paretic UE impairment in patients with active wrist and finger movement. Objective The aim of this study was to determine performance on the w/h UE FM in a stable cohort of survivors of stroke with only palpable movement in their paretic wrist flexors. Design A single-center cohort study was conducted. Method Thirty-two individuals exhibiting stable, moderate upper extremity hemiparesis (15 male, 17 female; mean age=56.6 years, SD=10.1; mean time since stroke=4.6 years, SD=5.8) participated in the study, which was conducted at an outpatient rehabilitation clinic in the midwestern United States. The w/h UE FM and Action Research Arm Test (ARAT) were administered twice. Intraclass correlation coefficients (ICCs), Cronbach alpha, and ordinal alpha were computed to determine reliability, and Spearman rank correlation coefficients and Bland-Altman plots were computed to establish validity. Results Intraclass correlation coefficients for the w/h UE FM and ARAT were .95 and .99, respectively. The w/h UE FM intrarater reliability and internal consistency were greater than .80, and concurrent validity was greater than .70. This also was the first stroke rehabilitative study to apply ordinal alpha to examine internal consistency values, revealing w/h UE FM levels greater than .85. Concurrent validity findings were corroborated by Bland-Altman plots. Conclusions It appears that the w/h UE FM is a promising tool to measure distal upper extremity movement in patients with little active paretic wrist and finger movement. This finding widens the segment of patients on whom the w/h UE FM can be effectively used and addresses a gap, as commonly used measures necessitate active distal upper extremity movement.


2016 ◽  
Vol 21 (01) ◽  
pp. 72-77 ◽  
Author(s):  
Takashi Oda ◽  
Yukio Abe ◽  
Yasukazu Katsumi ◽  
Hiroyuki Ohi ◽  
Toshiyasu Nakamura ◽  
...  

Background: The Michigan Hand Outcomes Questionnaire (MHQ) has shown reliability, validity and responsiveness and has been used to assess surgical outcomes mainly in North America. We established a Japanese version of the MHQ and evaluated its reliability and validity compared with both the short-form 36 (SF-36) questionnaire and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire in a Japanese-speaking population. Methods: The MHQ was cross-culturally adapted to a Japanese version according to guidelines. Sixty-eight patients with hand conditions were enrolled in this study and answered the MHQ, DASH questionnaire and SF-36 questionnaire. The MHQ was completed again with an interval of one or two weeks. Reproducibility and internal consistency were statistically assessed by the test-retest method and calculating Cronbach's alpha. Spearman's rank correlation was calculated to assess associations between the MHQ and the SF-36 questionnaire as well as the DASH questionnaire. Results: The intraclass correlation coefficients of MHQ subscales ranged from 0.68 to 0.93. Aesthetics subscale of the left hand showed the lowest intraclass correlation but still a good correlation. Cronbach's alpha values of the MHQ ranged from 0.81 to 0.96 for all subscales. The absolute values of Spearman's rank correlation coefficient between MHQ subscales and DASH function/symptoms scores ranged from 0.49 to 0.82. Spearman's correlation coefficients of the MHQ total score to subscales of the SF-36 questionnaire ranged from 0.42 to 0.68. The strongest correlations were found between work performance of the MHQ and rolephysical of the SF-36 questionnaire. Conclusions: The Japanese version of the MHQ has adequate instrument properties for assessing hand outcomes compared with the SF-36 questionnaire as well as the DASH questionnaire.


2018 ◽  
Vol 30 (3) ◽  
pp. 377-385 ◽  
Author(s):  
Patti K. Kiser ◽  
Christiane V. Löhr ◽  
Danielle Meritet ◽  
Sean T. Spagnoli ◽  
Milan Milovancev ◽  
...  

Although quantitative assessment of margins is recommended for describing excision of cutaneous malignancies, there is poor understanding of limitations associated with this technique. We described and quantified histologic artifacts in inked margins and determined the association between artifacts and variance in histologic tumor-free margin (HTFM) measurements based on a novel grading scheme applied to 50 sections of normal canine skin and 56 radial margins taken from 15 different canine mast cell tumors (MCTs). Three broad categories of artifact were 1) tissue deformation at inked edges, 2) ink-associated artifacts, and 3) sectioning-associated artifacts. The most common artifacts in MCT margins were ink-associated artifacts, specifically ink absent from an edge (mean prevalence: 50%) and inappropriate ink coloring (mean: 45%). The prevalence of other artifacts in MCT skin was 4–50%. In MCT margins, frequency-adjusted kappa statistics found fair or better inter-rater reliability for 9 of 10 artifacts; intra-rater reliability was moderate or better in 9 of 10 artifacts. Digital HTFM measurements by 5 blinded pathologists had a median standard deviation (SD) of 1.9 mm (interquartile range: 0.8–3.6 mm; range: 0–6.2 mm). Intraclass correlation coefficients demonstrated good inter-pathologist reliability in HTFM measurement (κ = 0.81). Spearman rank correlation coefficients found negligible correlation between artifacts and HTFM SDs ( r ≤ 0.3). These data confirm that although histologic artifacts commonly occur in inked margin specimens, artifacts are not meaningfully associated with variation in HTFM measurements. Investigators can use the grading scheme presented herein to identify artifacts associated with tissue processing.


2004 ◽  
Vol 7 (6) ◽  
pp. 723-727 ◽  
Author(s):  
Elizabeth A Spencer ◽  
Andrew W Roddam ◽  
Timothy J Key

AbstractObjective:To assess the accuracy of self-reported waist and hip circumferences and the waist-to-hip ratio (WHR) by comparison with measured waist and hip circumferences and WHR in a sample of middle-aged men and women.Design:Analysis of measured and self-reported waist and hip data from participants in the Oxford cohort of the European Prospective Investigation into Cancer and Nutrition (EPIC–Oxford).Participants:Four thousand four hundred and ninety-two British men and women aged 35–76 years.Results:Spearman's rank correlation coefficients between measured and self-reported waist, hip and WHR were 0.80, 0.74 and 0.44, respectively, for men and 0.83, 0.86 and 0.62 for women. Waist was underestimated, on average, by 3.1 (standard deviation (SD) 5.6) cm in men and 1.9 (SD 5.4) cm in women. The extent of underestimation was greater in participants with larger waists, older participants and women with greater body mass index (BMI). Hip was underestimated by a mean of 1.8 (SD 4.9) cm in men and 1.2 (SD 4.5) cm in women; the extent of underestimation was greater in participants with larger hip circumference and older participants. On average, WHR was underestimated by less than 2% by men and women; the extent of underestimation was greater among those with larger WHR, older people and those with greater BMI. Using self-reported values, the proportion of classification to the correct tertile was over 65% for waist and hip measurements. For WHR this proportion was 50% among men and 60% among women.Conclusions:Self-reported waist and hip measurements in EPIC–Oxford are sufficiently accurate for identifying relationships in epidemiological studies.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


Sign in / Sign up

Export Citation Format

Share Document