The Focused Ion Beam Fold-Out: Sample Preparation Method for Transmission Electron Microscopy

2009 ◽  
Vol 15 (6) ◽  
pp. 558-563 ◽  
Author(s):  
Herman Carlo Floresca ◽  
Jangbae Jeon ◽  
Jinguo G. Wang ◽  
Moon J. Kim

AbstractWe have developed the focused ion beam (FIB) fold-out technique, for transmission electron microscopy (TEM) sample preparation in which there is no fine polishing or dimpling, thus saving turnaround time. It does not require a nanomanipulator yet is still site specific. The sample wafer is cut to shape, polished down, and then placed in a FIB system. A tab containing the area of interest is created by ion milling and then “folded out” from the bulk sample. This method also allows a plan-view of the sample by removing material below the wafer's surface film or device near the polished edge. In the final step, the sample is thinned to electron transparency, ready to be analyzed in the TEM. With both a cross section and plan-view, our technique gives microscopists a powerful tool in analyzing multiple zone axes in one TEM session. The nature of the polished sample edge also includes the ability to sample many areas, allowing the user to examine a very large device or sample. More importantly, this technique could make multiple site-specific e-beam transparent specimens in one polished sample, which is difficult to do when prepared by other methods.

2001 ◽  
Vol 7 (S2) ◽  
pp. 948-949
Author(s):  
R. S. Rai ◽  
S. Bagchi ◽  
L. Duncan ◽  
L. Prabhu ◽  
J. Beck ◽  
...  

In recent years, the availability of focused ion beam (FIB) milling systems has given a much-needed boost for transmission electron microscopy (TEM) as a technique for site-specific analysis. Much progress has been made in the area of site-specific cross-sectional and planar TEM sample preparation techniques. However, a continuing need exists to reduce the sample preparation time, in order to improve TEM cycle time for better support of process development, yield improvement and production in a high-volume industrial environment. Thus, a faster TEM sample preparation technique is always desirable to meet this demand. A new approach to TEM sample preparation is described in this paper.Following the new approach developed in the present work, one can prepare on a single TEM grid at least two different cross-sectional samples of site-specific device structures or up to four different cross-sectional samples of blanket films. Two different samples, each containing an area of interest near the center, are cleaved or cut to a width of about 1.25 mm; these samples may be from two separate locations of a wafer, or from two different wafers where TEM analyses are required.


Author(s):  
Ching Shan Sung ◽  
Hsiu Ting Lee ◽  
Jian Shing Luo

Abstract Transmission electron microscopy (TEM) plays an important role in the structural analysis and characterization of materials for process evaluation and failure analysis in the integrated circuit (IC) industry as device shrinkage continues. It is well known that a high quality TEM sample is one of the keys which enables to facilitate successful TEM analysis. This paper demonstrates a few examples to show the tricks on positioning, protection deposition, sample dicing, and focused ion beam milling of the TEM sample preparation for advanced DRAMs. The micro-structures of the devices and samples architectures were observed by using cross sectional transmission electron microscopy, scanning electron microscopy, and optical microscopy. Following these tricks can help readers to prepare TEM samples with higher quality and efficiency.


Author(s):  
Chin Kai Liu ◽  
Chi Jen. Chen ◽  
Jeh Yan.Chiou ◽  
David Su

Abstract Focused ion beam (FIB) has become a useful tool in the Integrated Circuit (IC) industry, It is playing an important role in Failure Analysis (FA), circuit repair and Transmission Electron Microscopy (TEM) specimen preparation. In particular, preparation of TEM samples using FIB has become popular within the last ten years [1]; the progress in this field is well documented. Given the usefulness of FIB, “Artifact” however is a very sensitive issue in TEM inspections. The ability to identify those artifacts in TEM analysis is an important as to understanding the significance of pictures In this paper, we will describe how to measure the damages introduced by FIB sample preparation and introduce a better way to prevent such kind of artifacts.


Sign in / Sign up

Export Citation Format

Share Document