scholarly journals The First Results from “Solar X-ray Spectrometer (SOXS)” Mission

2005 ◽  
Vol 13 ◽  
pp. 622-622 ◽  
Author(s):  
Rajmal Jain ◽  
Hemant Dave ◽  
P. Sreekumar ◽  
A. B. Shah ◽  
N. M. Vadher ◽  
...  

Abstract“Solar X-ray Spectrometer (SOXS)” mission on-board GSAT-2 Indian spacecraft was launched on 08 May 2003 by GSLV-D2 and deployed in geostationery orbit to study the X-ray emission from solar flares with high spectral and temporal resolution. The SOXS consists of two independent payloads viz. SOXS Low Energy Detector (SLD) payload, and SOXS High Energy Detector (SHD) payload. The SLD consists of two solid state detectors Si PIN and CZT, which cover the energy range from 4-60 keV, while the SHD has NaI(Tl)/CsI(Na) sandwiched phoswich detector that covers energy range from 20 keV to 10 MeV. We present very briefly the science objectives and instrumentation of SLD payload. After the successful In-orbit Tests (IOT), the first light was fed into SLD payload on 08 June 2003 when the solar flare was already in progress. We briefly present the first results from the SLD payload.

1990 ◽  
Vol 142 ◽  
pp. 445-447
Author(s):  
R. R. Rausaria ◽  
Ranjana Bakaya ◽  
P.N. Khosa

Solar flare hard X-ray data obtained by Prognoz-9 spacecraft (Abrosimov et al 1988) in the energy range 10-200 keV are analysed. In examples of events which we consider here, high energy X-ray pulses appear earlier than low energy ones, which is contrary to many other events where the low energy X-ray peak emission takes place earlier. The variation of the spectral index was dynamical.


2012 ◽  
Vol 8 (S294) ◽  
pp. 571-572 ◽  
Author(s):  
Tomasz Mrozek ◽  
Szymon Gburek ◽  
Marek Siarkowski ◽  
Barbara Sylwester ◽  
Janusz Sylwester ◽  
...  

AbstractIn February 2009, during recent deepest solar minimum, Polish Solar Photometer in X-rays (SphinX) begun observations of the Sun in the energy range of 1.2–15 keV. SphinX was almost 100 times more sensitive than GOES X-ray Sensors. The silicon PIN diode detectors used in the experiment were carefully calibrated on the ground using Synchrotron Radiation Source BESSY II. The SphinX energy range overlaps with the Ramaty High Energy Solar Spectroscopic Imager (RHESSI) energy range. The instrument provided us with observations of hundreds of very small flares and X-ray brightenings. We have chosen a group of solar flares observed simultaneously with GOES, SphinX and RHESSI and performed spectroscopic analysis of observations wherever possible. The analysis of thermal part of the spectra showed that SphinX is a very sensitive complementary observatory for RHESSI and GOES.


1968 ◽  
Vol 35 ◽  
pp. 480-482
Author(s):  
C. De Jager

A solar flare has various aspects: the optical flare is often associated with emissions in the microwave or X-ray regions: this indicates the occurrence of a highly excited plasma, which we call the high-energy flare plasma. The existence of the high-energy flare plasma was first shown by radio observations in the microwave regions (Hachenberg) and later confirmed by X-ray observations in the energy range 102–106 eV.


1997 ◽  
Vol 487 ◽  
Author(s):  
M. Bavdaz ◽  
S. Kraft ◽  
A. Peacock ◽  
F. Scholze ◽  
M. Wedowski ◽  
...  

AbstractThe use of some specific compound semiconductors in the fabrication of high energy X-ray detectors shows significant potential for X-ray astrophysics space missions. We are currently investigating three high purity crystals - CdZnTe, GaAs and TlBr - as the basis for future hard X-ray detectors (above 10 keV). In this paper we present the first results on CdZnTe and GaAs based detectors and evaluate the factors currently still constraining the performance.Energy resolutions (FWHM) of 0.9 keV and 1.1 keV at 14 keV and 60 keV, respectively, have been obtained with an epitaxial GaAs detector, while 0.7 keV and 1.5 keV FWHM were measured at the same energies with a CdZnTe detector. Based on these results it is clear, that the next generation of X-ray astrophysics missions now in the planning phase may well consider extending the photon energy range up to ∼100 keV by use of efficient detectors with reasonable spectroscopic capabilities.


2005 ◽  
Vol 14 (06) ◽  
pp. 947-956
Author(s):  
D. C. MEI ◽  
L. ZHANG

We study the Doppler factors for a group blazars at soft X-ray band. In our estimates, we have made the assumptions that (i) blazars can be divided into high-energy-peaked (HEP) objects whose synchrotron peak frequencies νp > 1014.7 Hz , and the low-energy-peaked (LEP) objects whose synchrotron peak frequencies νp≤1014.7 Hz , and (ii) the intrinsic radiation from a blazar in the energy range from radio to soft X-ray bands is the synchrotron radiation for HEP objects and the soft X-ray emission comes from inverse Compton scattering for LEP objects. Under the above assumptions, we estimate Doppler factors at optical (δO) and X-rays (δx) for 54 blazars by using the known radio Doppler factors and the observed flux densities in radio, optical and X-ray bands, and Doppler factors [Formula: see text] at X-ray band in which X-rays are assumed to be produced only by the synchrotron radiation. We get [Formula: see text] . The Doppler factors are different in various wavebands, and on average, the Doppler factor decreases with frequency from radio to X-ray bands.


2021 ◽  
Vol 11 (10) ◽  
pp. 4349
Author(s):  
Tianzhong Xiong ◽  
Wenhua Ye ◽  
Xiang Xu

As an important part of pretreatment before recycling, sorting has a great impact on the quality, efficiency, cost and difficulty of recycling. In this paper, dual-energy X-ray transmission (DE-XRT) combined with variable gas-ejection is used to improve the quality and efficiency of in-line automatic sorting of waste non-ferrous metals. A method was proposed to judge the sorting ability, identify the types, and calculate the mass and center-of-gravity coordinates according to the shading of low-energy, the line scan direction coordinate and transparency natural logarithm ratio of low energy to high energy (R_value). The material identification was satisfied by the nearest neighbor algorithm of effective points in the material range to the R_value calibration surface. The flow-process of identification was also presented. Based on the thickness of the calibration surface, the material mass and center-of-gravity coordinates were calculated. The feasibility of controlling material falling points by variable gas-ejection was analyzed. The experimental verification of self-made materials showed that identification accuracy by count basis was 85%, mass and center-of-gravity coordinates calculation errors were both below 5%. The method proposed features high accuracy, high efficiency, and low operation cost and is of great application value even to other solid waste sorting, such as plastics, glass and ceramics.


2011 ◽  
Vol 21 (15) ◽  
pp. 5604 ◽  
Author(s):  
Zonghai Chen ◽  
Yang Ren ◽  
Yan Qin ◽  
Huiming Wu ◽  
Shengqian Ma ◽  
...  

Author(s):  
P. Laurent ◽  
F. Acero ◽  
V. Beckmann ◽  
S. Brandt ◽  
F. Cangemi ◽  
...  

AbstractBased upon dual focusing techniques, the Polarimetric High-Energy Modular Telescope Observatory (PHEMTO) is designed to have performance several orders of magnitude better than the present hard X-ray instruments, in the 1–600 keV energy range. This, together with its angular resolution of around one arcsecond, and its sensitive polarimetry measurement capability, will give PHEMTO the improvements in scientific performance needed for a mission in the 2050 era in order to study AGN, galactic black holes, neutrons stars, and supernovae. In addition, its high performance will enable the study of the non-thermal processes in galaxy clusters with an unprecedented accuracy.


2014 ◽  
Vol 54 (4) ◽  
pp. 285-289 ◽  
Author(s):  
Francesco Schillaci ◽  
Giuseppe A. P. Cirrone ◽  
George Korn ◽  
Mario Maggiore ◽  
Daniele Margarone ◽  
...  

ELI-Beamlines is one of the four pillars of the ELI (Extreme Light Infrastructure) pan-European project. It will be an ultrahigh-intensity, high repetition-rate, femtosecond laser facility whose main goal is to generate and apply high-brightness X-ray sources and accelerated charged particles. In particular, medical applications are treated by the ELIMED task force, which has been launched by collaboration between ELI and INFN researchers. ELIMED aims to demonstrate the clinical applicability of laser accelerated ions. In this article, the state of the ELIMED project and the first scientific results are reported. The design and realisation of a preliminary beam handling system and of an advanced spectrometer for diagnostics of high energy (multi-MeV) laser-accelerated ion beams will also be briefly presented.


1970 ◽  
Vol 48 (18) ◽  
pp. 2155-2161 ◽  
Author(s):  
C. Y. Kim

An attempt to measure the flux of high-energy solar neutrons was made by measuring the difference in flux from the direction of the sun and from the symmetrical direction about the zenith, using oriented nuclear emulsions flown by balloon on July 30, 1966 from Fort Churchill, Manitoba.An excess of (2.2 ± 2.5) × 10−2 neutrons cm−2 s−1 was observed from the direction of the sun in the energy region of 20–160 MeV. On the day of the flight the sunspot number was 63, and no major solar flares were reported.


Sign in / Sign up

Export Citation Format

Share Document