High-Sensitivity Sensing of Divalent Copper Ions at the Single Upconversion Nanoparticle Level

Author(s):  
Xindong Wang ◽  
Xiaorong Zhang ◽  
Dingxin Huang ◽  
Tianyu Zhao ◽  
Lili Zhao ◽  
...  
Nanomaterials ◽  
2018 ◽  
Vol 9 (1) ◽  
pp. 32 ◽  
Author(s):  
Zhezhe Wang ◽  
Xuechun Xiao ◽  
Tong Zou ◽  
Yue Yang ◽  
Xinxin Xing ◽  
...  

Citric acid capped CdS quantum dots (CA-CdS QDs), a new assembled fluorescent probe for copper ions (Cu2+), was synthesized successfully by a simple hydrothermal method. In this work, the fluorescence sensor for the detection of heavy and transition metal (HTM) ions has been extensively studied in aqueous solution. The results of the present study indicate that the obtained CA-CdS QDs could detect Cu2+ with high sensitivity and selectivity. It found that the existence of Cu2+ has a significant fluorescence quenching with a large red shifted (from greenish-yellow to yellowish-orange), but not in the presence of 17 other HTM ions. As a result, Cu2S, the energy level below the CdS conduction band, could be formed at the surface of the CA-CdS QDs and leads to the quenching of fluorescence of CA-CdS QDs. Under optimal conditions, the copper ions detection range using the synthesized fluorescence sensor was 1.0 × 10‒8 M to 5.0 × 10‒5 M and the limit of detection (LOD) is 9.2 × 10‒9 M. Besides, the as-synthesized CA-CdS QDs sensor exhibited good selectivity toward Cu2+ relative to other common metal ions. Thus, the CA-CdS QDs has potential applications for detecting Cu2+ in real water samples.


Chemosensors ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 47 ◽  
Author(s):  
Jiang ◽  
Lu ◽  
Su ◽  
Feng ◽  
Zhou ◽  
...  

Cadmium selenide (CdSe) quantum dots (QDs) were synthesized by water phase synthesis method using 3-mercaptopropionic acid (3-MPA) as a stabilizer, and they were applied to the detection of copper ions (Cu2+). The results showed that CdSe QDs have excellent selectivity and sensitivity toward Cu2+. The fluorescence intensity of CdSe QDs decreased with the increase of Cu2+ concentration. The linear range was from 30 nM to 3 μM, and the detection limit was 30 nM. Furthermore, CdSe QDs were used for detecting the concentration of Cu2+ in oysters. The content of Cu2+ was 40.91 mg/kg, which was close to the one measured via flame atomic absorption spectrometry (FAAS), and the relative error was 1.81%. Therefore, CdSe QDs have a wide application prospect in the rapid detection of copper ions in food.


Author(s):  
D. V. Tolkachev ◽  
A. A. Khodak ◽  
S. P. Solodovnikov ◽  
N. N. Bubnov ◽  
M. I. Kabachnik

2017 ◽  
Vol 46 (8) ◽  
pp. 2456-2461 ◽  
Author(s):  
Tian-Tian Zheng ◽  
Jiao Zhao ◽  
Zhou-Wen Fang ◽  
Meng-Ting Li ◽  
Chun-Yi Sun ◽  
...  

Cd-MOF-74shows high sensitivity and efficiency in the detection and removal of copper ions from water and simulated biological fluids.


2021 ◽  
Author(s):  
Magal Saphier ◽  
Lea Moshkovich ◽  
Stanislav Popov ◽  
Yoram Shotland ◽  
Eldad Silberstein ◽  
...  

Abstract The effect of monovalent copper ions on enzymatic systems has hardly been studied to date; this is due to the low stability of monovalent copper ions in aqueous solutions, which led to the assumption that their concentration is negligible in biological systems. However, in an anaerobic atmosphere, and in the presence of a ligand that stabilizes the monovalent copper ions over the divalent copper ions, high and stable concentrations of monovalent copper ions can be reached. Moreover, the cell cytoplasm has a substantial concentration of potential stabilizers that can explain significant concentrations of monovalent copper ions in the cytoplasm. This study demonstrates the effect of monovalent and divalent copper ions on DNA polymerase, ligaseT4 DNA, the restriction enzymes EcoP15I and EcoR I, acid phosphatase, and α and βamylase enzymes. These systems were chosen because they can be monitored under conditions necessary for maintaining a stable concentration of monovalent copper ions, and since they exhibit a wide range of dependency on ATP. Previous studies indicated that ATP interacts with monovalent and divalent copper ions and stabilizing monovalent copper ions over divalent copper ions. The results showed that monovalent copper ions dramatically inhibit DNA polymerase and acid phosphatase, inhibit ligaseT4 DNA and the restriction enzyme EcoP15I, moderately inhibit α and β amylase, and have no effect on the restriction enzyme EcoR I. From the results presented in this work, it can be concluded that the mechanism is not one of oxidative stress, even though monovalent copper ions generate reactive oxygen species (ROS). Molecular oxygen in the medium, which is supposed to increase the oxidative stress, impairs the inhibitory effect of monovalent and divalent copper ions, and the kinetics of the inhibition is not suitable for the ROS mechanism.ATP forms a complex with copper ions (di and monovalent ions, where the latter is more stable) in which the metal ion is bound both to the nitrogen base and to the oxygen charged on the phosphate groups, forming an unusually distorted complex. The results of this study indicate that these complexes have the ability to inhibit enzymatic systems that are dependent on ATP.This finding can provide an explanation for the strong antimicrobial activity of monovalent copper ions, suggesting that rapid and lethal metabolic damage is the main mechanism of monovalent copper ions’ antimicrobial effect.


1984 ◽  
Vol 25 (3-4) ◽  
pp. 237-241 ◽  
Author(s):  
G. P. Potapov ◽  
E. I. Kazakova ◽  
V. A. Poluboyarov ◽  
V. F. Anufrienko

Micromachines ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 63 ◽  
Author(s):  
Ziyue Wu ◽  
Jiaqi Wang ◽  
Chao Bian ◽  
Jianhua Tong ◽  
Shanhong Xia

As an important means to protect water resources, water quality detection is of great social and economic significance. Water quality detection sensors processed by micro-electro-mechanical system (MEMS) technology have the advantages of low-cost, small size, and high sensitivity. In this paper, a multi-parameter water quality detection integrated sensor chip is further studied, and a portable detection system using this chip is developed. Temperature, pH, oxidation-reduction potential (ORP), conductivity and concentration of copper ions (Cu2+) are selected as typical water quality parameters. Experiments of sensor calibrations using this portable detection system were performed in standard solutions. The sensor has a sensitivity of −57.34 mV/pH in pH detection and 5.95 Ω/°C in temperature response. ORP is directly detected by Pt microelectrode on the chip and the relative error is less than 3%. The electrode constant of the sensor is 1.416 cm−1 and the linearity is 0.9995 in conductivity detection. With the gold nanoparticles deposited on the electrode, the detection peak of Cu2+ appears at 280 mV and the sensor shows good linearity to the concentration of Cu2+ in the range of 0–0.6 mg/L. The detection limit of Cu2+ concentration is 2.33 μg/L. Through measurement and calculation, the accuracy of the portable system is within 4%. This portable multi-parameter water quality detection system with the MEMS-based integrated chip shows great potential in the field and fast detection.


Sign in / Sign up

Export Citation Format

Share Document