scholarly journals Low-Cost, User-Friendly, All-Integrated Smartphone-Based Microplate Reader for Optical-Based Biological and Chemical Analyses

Author(s):  
José Francisco Bergua ◽  
Ruslán Álvarez-Diduk ◽  
Andrea Idili ◽  
Claudio Parolo ◽  
Marc Maymó ◽  
...  
2012 ◽  
Vol 44 (2) ◽  
pp. 75-93
Author(s):  
Peter Mortensen

This essay takes its cue from second-wave ecocriticism and from recent scholarly interest in the “appropriate technology” movement that evolved during the 1960s and 1970s in California and elsewhere. “Appropriate technology” (or AT) refers to a loosely-knit group of writers, engineers and designers active in the years around 1970, and more generally to the counterculture’s promotion, development and application of technologies that were small-scale, low-cost, user-friendly, human-empowering and environmentally sound. Focusing on two roughly contemporary but now largely forgotten American texts Sidney Goldfarb’s lyric poem “Solar-Heated-Rhombic-Dodecahedron” (1969) and Gurney Norman’s novel Divine Right’s Trip (1971)—I consider how “hip” literary writers contributed to eco-technological discourse and argue for the 1960s counterculture’s relevance to present-day ecological concerns. Goldfarb’s and Norman’s texts interest me because they conceptualize iconic 1960s technologies—especially the Buckminster Fuller-inspired geodesic dome and the Volkswagen van—not as inherently alienating machines but as tools of profound individual, social and environmental transformation. Synthesizing antimodernist back-to-nature desires with modernist enthusiasm for (certain kinds of) machinery, these texts adumbrate a humanity- and modernity-centered post-wilderness model of environmentalism that resonates with the dilemmas that we face in our increasingly resource-impoverished, rapidly warming and densely populated world.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Yehe Liu ◽  
Andrew M. Rollins ◽  
Richard M. Levenson ◽  
Farzad Fereidouni ◽  
Michael W. Jenkins

AbstractSmartphone microscopes can be useful tools for a broad range of imaging applications. This manuscript demonstrates the first practical implementation of Microscopy with Ultraviolet Surface Excitation (MUSE) in a compact smartphone microscope called Pocket MUSE, resulting in a remarkably effective design. Fabricated with parts from consumer electronics that are readily available at low cost, the small optical module attaches directly over the rear lens in a smartphone. It enables high-quality multichannel fluorescence microscopy with submicron resolution over a 10× equivalent field of view. In addition to the novel optical configuration, Pocket MUSE is compatible with a series of simple, portable, and user-friendly sample preparation strategies that can be directly implemented for various microscopy applications for point-of-care diagnostics, at-home health monitoring, plant biology, STEM education, environmental studies, etc.


Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 697
Author(s):  
Siming Lu ◽  
Sha Lin ◽  
Hongrui Zhang ◽  
Liguo Liang ◽  
Shien Shen

Respiratory viral infections threaten human life and inflict an enormous healthcare burden worldwide. Frequent monitoring of viral antibodies and viral load can effectively help to control the spread of the virus and make timely interventions. However, current methods for detecting viral load require dedicated personnel and are time-consuming. Additionally, COVID-19 detection is generally relied on an automated PCR analyzer, which is highly instrument-dependent and expensive. As such, emerging technologies in the development of respiratory viral load assays for point-of-care (POC) testing are urgently needed for viral screening. Recent advances in loop-mediated isothermal amplification (LAMP), biosensors, nanotechnology-based paper strips and microfluidics offer new strategies to develop a rapid, low-cost, and user-friendly respiratory viral monitoring platform. In this review, we summarized the traditional methods in respiratory virus detection and present the state-of-art technologies in the monitoring of respiratory virus at POC.


Author(s):  
Jing Li ◽  
Dingyong Yu ◽  
Huaxing Liu

The passive acoustic-based wave measurement via hydrophones is presented in this paper. It has the potential to measure non-intrusively, implement with low cost and with higher resolution. Details of experiments, real-time data recording and processing are described respectively. Particularly, the portable data acquisition system based on virtual instrument technique is designed to make the in situ measurement convenient and user-friendly. Special emphasis is put on FFT filtering technique to band pass the signal fast and efficiently. The key wave parameters, i.e. the mean wave period and the significant wave height, can be obtained from the comparatively safe and stable underwater by means of submerged hydrophones. Considering the pressure sensor has been widely used in the ocean wave measurement, it is deployed simultaneously to test the feasibility of the new system. The result shows that the present measuring system can give satisfactory measurement of significant wave heights and average wave periods in shallow water despite of the little deviation.


Author(s):  
W. Ostrowski ◽  
K. Hanus

One of the popular uses of UAVs in photogrammetry is providing an archaeological documentation. A wide offer of low-cost (consumer) grade UAVs, as well as the popularity of user-friendly photogrammetric software allowing obtaining satisfying results, contribute to facilitating the process of preparing documentation for small archaeological sites. However, using solutions of this kind is much more problematic for larger areas. The limited possibilities of autonomous flight makes it significantly harder to obtain data for areas too large to be covered during a single mission. Moreover, sometimes the platforms used are not equipped with telemetry systems, which makes navigating and guaranteeing a similar quality of data during separate flights difficult. The simplest solution is using a better UAV, however the cost of devices of such type often exceeds the financial capabilities of archaeological expeditions. <br><br> The aim of this article is to present methodology allowing obtaining data for medium scale areas using only a basic UAV. The proposed methodology assumes using a simple multirotor, not equipped with any flight planning system or telemetry. Navigating of the platform is based solely on live-view images sent from the camera attached to the UAV. The presented survey was carried out using a simple GoPro camera which, from the perspective of photogrammetric use, was not the optimal configuration due to the fish eye geometry of the camera. Another limitation is the actual operational range of UAVs which in the case of cheaper systems, rarely exceeds 1 kilometre and is in fact often much smaller. Therefore the surveyed area must be divided into sub-blocks which correspond to the range of the drone. It is inconvenient since the blocks must overlap, so that they will later be merged during their processing. This increases the length of required flights as well as the computing power necessary to process a greater number of images. <br><br> These issues make prospection highly inconvenient, but not impossible. Our paper presents our experiences through two case studies: surveys conducted in Nepal under the aegis of UNESCO, and works carried out as a part of a Polish archaeological expedition in Cyprus, which both prove that the proposed methodology allows obtaining satisfying results. The article is an important voice in the ongoing debate between commercial and academic archaeologists who discuss the balance between the required standards of conducting archaeological works and economic capabilities of archaeological missions.


Micromachines ◽  
2021 ◽  
Vol 12 (12) ◽  
pp. 1464
Author(s):  
Florina Silvia Iliescu ◽  
Ana Maria Ionescu ◽  
Larisa Gogianu ◽  
Monica Simion ◽  
Violeta Dediu ◽  
...  

The deleterious effects of the coronavirus disease 2019 (COVID-19) pandemic urged the development of diagnostic tools to manage the spread of disease. Currently, the “gold standard” involves the use of quantitative real-time polymerase chain reaction (qRT-PCR) for SARS-CoV-2 detection. Even though it is sensitive, specific and applicable for large batches of samples, qRT-PCR is labour-intensive, time-consuming, requires trained personnel and is not available in remote settings. This review summarizes and compares the available strategies for COVID-19: serological testing, Point-of-Care Testing, nanotechnology-based approaches and biosensors. Last but not least, we address the advantages and limitations of these methods as well as perspectives in COVID-19 diagnostics. The effort is constantly focused on understanding the quickly changing landscape of available diagnostic testing of COVID-19 at the clinical levels and introducing reliable and rapid screening point of care testing. The last approach is key to aid the clinical decision-making process for infection control, enhancing an appropriate treatment strategy and prompt isolation of asymptomatic/mild cases. As a viable alternative, Point-of-Care Testing (POCT) is typically low-cost and user-friendly, hence harbouring tremendous potential for rapid COVID-19 diagnosis.


Author(s):  
Lara Rebaioli ◽  
Irene Fassi

Abstract Lab on Chips (LOCs) are devices, mostly based on microfluidics, that allow to perform one or several chemical, biochemical or biological analysis in a miniaturized format on a single chip. The Additive Manufacturing processes, and in particular the Digital Light Processing stereolithography (DLP-SLA), could quickly produce a complete LOC with high resolution 3D features in a single step, i.e. without the need for assembly processes, and using low cost and user-friendly desktop machines. However, the potential of DLP-SLA to produce non-planar channels or channels with complex sections has not been fully investigated yet. This study proposes a benchmark artifact (including also some channels with their axis lying in a plane parallel to the machine building platform) aiming at assessing the capability and performance of DLP-SLA for manufacturing microfeatures for microfluidic devices. A proper experimental campaign was performed to evaluate the effect of the main process parameters (namely, layer thickness and exposure time) on the process performance. The results pointed out that both the process parameters influence the quality and dimensional accuracy of the analyzed features.


Sign in / Sign up

Export Citation Format

Share Document