Effects of Chlorine Exposure Conditions on Physiochemical Properties and Performance of a Polyamide Membrane—Mechanisms and Implications

2012 ◽  
Vol 46 (24) ◽  
pp. 13184-13192 ◽  
Author(s):  
Van Thanh Do ◽  
Chuyang Y. Tang ◽  
Martin Reinhard ◽  
James O. Leckie
Author(s):  
Manudul Pahansen de Alwis ◽  
Riccardo LoMartire ◽  
Björn O Äng ◽  
Karl Garme

High-Performance Marine Craft (HPMC) occupants are currently being investigated for various psychophysical impairments degrading work performance postulating that these deteriorations are related to their occupational exposures. However, scientific evidence for this is lacking and the association of exposure conditions aboard HPMC with adverse health and performance effects is unknown. Therefore, the study estimates the prevalence of musculoskeletal pain (MSP) among HPMC occupants and the association of their work exposure with MSP and performance degradation. It also presents a criterion for evaluating the self-reported exposure severity aboard three different types of mono-hull HPMC; displacement, semi-displacement and planing, on a par with the available standard criteria for objectively measurable exposures. Furthermore, another criterion is proposed to assess the performance-degradation of HPMC occupants based on self-reported fatigue symptoms and MSP. Swedish Coast Guard HPMC occupants were surveyed for MSP, fatigue symptoms as well as for work-related and individual risk indicators using a validated web-based questionnaire. Prevalence of MSP and performance-degradation during the past 12 months were assessed and presented as a percentage of the sample. Associations of exposure conditions aboard HPMC with MSP and performance-capacity were systematically evaluated using multiple logistic regression models and expressed as odds ratio (OR). Prevalence of MSP was 72% among which lower back pain was the most prevalent (46%) followed by neck pain (29%) and shoulder pain (23%) while 29% with degraded performance. Exposure to severe conditions aboard semi-displacement craft was associated with lower back (OR = 2.3) and shoulder (OR = 2.6) pain while severe conditions aboard planing craft with neck pain (OR = 2.3) and performance-degradation (OR = 2.6). MSP is common among Swedish coast guards. Severe exposure conditions aboard HPMC are significantly associated with both MSP and performance-degradation. The spine and shoulders are the most susceptible to work-related MSP among HPMC occupants which should be targeted in work-related preventive and corrective measures.


2021 ◽  
Vol 287 ◽  
pp. 02003
Author(s):  
Muhammad Syahir Aminuddin ◽  
Zakaria Man ◽  
Mohamad Azmi Bustam Khalil ◽  
Bawadi Abdullah

In order to identify the best possible reaction media for performing H2S conversion, a total number of 300 different ILs from a combination of 20 cations and 15 anions were screened via COSMO-RS model simulations. By COSMO-RS method, thermodynamic and physicochemical properties of 300 ILs such as Henry’s law constants, activity coefficient, selectivity, capacity and performance index are obtained and analyzed. Thus, by comparing the performance of ILs via COSMO-RS, a series of TSILs containing cation of [P66614] with metal chloride anions such as Fe, Ga and Sn were chosen and selected for synthesis based on their performance predicted by COSMO-RS and their economic values. Consequently, the physiochemical properties such as density, viscosity, thermal properties, as well as H2S absorptive oxidation performances in those TSILs will be systematically investigated.


Nanomaterials ◽  
2018 ◽  
Vol 8 (9) ◽  
pp. 681 ◽  
Author(s):  
Alexandra-Cristina Burdușel ◽  
Oana Gherasim ◽  
Alexandru Mihai Grumezescu ◽  
Laurențiu Mogoantă ◽  
Anton Ficai ◽  
...  

During the past few years, silver nanoparticles (AgNPs) became one of the most investigated and explored nanotechnology-derived nanostructures, given the fact that nanosilver-based materials proved to have interesting, challenging, and promising characteristics suitable for various biomedical applications. Among modern biomedical potential of AgNPs, tremendous interest is oriented toward the therapeutically enhanced personalized healthcare practice. AgNPs proved to have genuine features and impressive potential for the development of novel antimicrobial agents, drug-delivery formulations, detection and diagnosis platforms, biomaterial and medical device coatings, tissue restoration and regeneration materials, complex healthcare condition strategies, and performance-enhanced therapeutic alternatives. Given the impressive biomedical-related potential applications of AgNPs, impressive efforts were undertaken on understanding the intricate mechanisms of their biological interactions and possible toxic effects. Within this review, we focused on the latest data regarding the biomedical use of AgNP-based nanostructures, including aspects related to their potential toxicity, unique physiochemical properties, and biofunctional behaviors, discussing herein the intrinsic anti-inflammatory, antibacterial, antiviral, and antifungal activities of silver-based nanostructures.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


Sign in / Sign up

Export Citation Format

Share Document