scholarly journals Impact of g force and timing on the characteristics of platelet-rich fibrin matrices

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ana B. Castro ◽  
C. Andrade ◽  
X. Li ◽  
N. Pinto ◽  
W. Teughels ◽  
...  

AbstractRecently, new centrifugation protocols for the preparation of platelet-rich fibrin (PRF) have been introduced in an attempt to further improve the beneficial impact of these 2nd generation platelet concentrate membranes. This in-vitro study aimed to compare the biological and physical characteristics of three types of PRF membranes using two different centrifuges with adapted relative centrifugal forces (RCF): leucocyte- and platelet-rich fibrin, advanced platelet-rich fibrin, and advanced platelet-rich fibrin+. Release of growth factors, macroscopic dimensions, cellular content and mechanical properties of the respective membranes, prepared from blood of the same individual were explored. Furthermore, the impact of timing (blood draw-centrifugation and centrifugation-membrane preparation) was assessed morphologically as well as by electron microscopy scanning. No statistically significant differences amongst the three PRF modifications could be observed, neither in their release of growth factors or the cellular content, nor in clot/membrane dimensions. The difference between both centrifuges were negligible when the same g-force was used. A lower g-force, however, reduced membrane tensile strength. Timing in the preparation process had a significant impact. Adaptation of RCF only had a minimal impact on the final characteristics of PRF membranes.

2010 ◽  
Vol 1 (3) ◽  
pp. 163-166
Author(s):  
Shelly Ahuja

ABSTRACT Introduction The major cellular events in the tissue repair are mitogenesis, migration and metabolism. The proteins responsible for coordination of these events are called “growth factors”. The activated platelets at the wound margins release several growth factors, such as PDGF, TGF-β and EGF, etc., and plasma exudates also provide an important source of TGF-β factors. Materials and methods Periodontal ligament fibroblast obtained from third molar impaction surgery, periodontal ligaments were cultured under standard conditions and spread on 96 well tissue culture plates. Platelet concentrate was obtained after centrifugation of 350-400 ml of blood at 1000 and 5000 rpm. 15 μl of platelet concentrate was added to each well. The proliferation rate of test and control group was determined by Redox indicator (Alamar blue® assay). The number of cells were counted by neu bar counting chamber after 24, 48 and 72 hours. Results The proliferation activity of cells was considerably higher in the platelet concentrate group (test group) than the control group. The difference was highly significant upto 72 hours after addition of platelet concentrates (Mann-Whitney U test p < 0.001). Conclusion A cellular effect of the platelet concentrate is clearly discernible. It was concluded that the use of platelet concentrate is an effective modality of regeneration.


2012 ◽  
Vol 506 ◽  
pp. 367-370
Author(s):  
N. Pattaraporncharoen ◽  
P. Pripatnanont ◽  
S. Suttapreyasri ◽  
N. Leepong

Platelet-rich fibrin (PRF) is platelet concentration that contains growth factors and acts as a biodegradable scaffold. The aims of this study were to determinethe quantity ofentrappedgrowth factors (Platelet derived growth factor BB, PDGF-BB) in the PRF and radiographically assess the stability of the fibrin in maintaining the lifted sinus space in minipigs. From the in vitro study, PRF was found slowly releasing thegrowth factor, PDGF-BB, during the ex-vivo period of 60 minutes, and the amount (1,963.93±380.17 pg/ml) was comparable to the total amount from immediate extraction either by physical (2,492.2±199.78 pg/ml) or chemical lysis (2,227.32±566.59 pg/ml).In vivo study, PRF wasable to be retained in the sinus of minipigs with minimal collapse during the first 2 weeks after application. PRF has been proven to be a source for growth factors and is able to be retained in the body during the initial period of wound healing.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2021 ◽  
Vol 11 (5) ◽  
pp. 2339
Author(s):  
Joanna Metlerska ◽  
Till Dammaschke ◽  
Mariusz Lipski ◽  
Irini Fagogeni ◽  
Anna Machoy-Mokrzyńska ◽  
...  

The aim of the present in vitro study was to investigate the effects of 10% and 40% citric acid (CA) on the color of calcium silicate–based cements (CSCs) in comparison to the effects of common root canal irrigants. Samples of six CSCs (n = 6)—ProRoot MTA (Dentsply, Tulsa, OK, USA), Biodentine (Septodont, Saint-Maur-des-Fossés, France), MTA Plus (Avalon Biomed Inc, by Prevest Denpro Limited, Jammu, India), MTA Repair HP (Angelus, Londrina, PR, Brazil), Ortho MTA (BioMTA, Seoul, Korea), and Retro MTA (BioMTA, Seoul, Korea)—were immersed in 10% and 40% CA as well as 15% EDTA, 2% NaOCl, 2% CHX, and 0.9% NaCl for 15 min, 1 h, and 24 h. ΔE values, representing the difference between the final and baseline values of the color components, were then determined using a VITA Easyshade Compact 5.0 spectrophotometer. Naked-eye evaluation of the changes in color and structures of the materials was performed using our own scale. Upon immersion of the materials in both 10% and 40% CA, there were statistically significant differences between spectrophotometric color measurement results for all CSCs (P < 0.05). However, CA does not cause dark discoloration, observable with the naked eye, of any of the materials, such as NaOCl and CHX. Significant statistical differences were also found between all CSCs in terms of submersion duration (P < 0.05). CA, which could be an alternative to EDTA use, caused greater CSCs discoloration and changed some of their structures. Unless required by the therapeutic procedure, clinicians should pay attention to the fact that the irrigant may affect the CSCs discoloration and minimize the contact time of irrigant with CSCs.


2021 ◽  
Vol 62 ◽  
pp. 473-476
Author(s):  
Ishandono Dachlan ◽  
Hendy Satrya Kurniawan ◽  
Aditya Wicaksana ◽  
Aditya Rifqi Fauzi ◽  
Firdian Makrufardi ◽  
...  

2021 ◽  
pp. 232020682110107
Author(s):  
Sandeep S. Katti ◽  
Kishore Bhat ◽  
Chetana Bogar

Aim: The aim of the current study was to isolate stem cells from various dental sources such as dental pulp, periodontal ligament (PDL), and apical papilla, and to characterize stem cells by staining for the presence/absence of specific surface markers and also to differentiate stem cells into osteogenic, chondrogenic, and adipogenic cell lineages by exposing them to specific growth factors under the ideal conditions. Materials and Methods: A total of 117 samples were included in the study, consisting of 30 pulp, 50 gingival, 35 PDL, and 2 apical papilla samples. The pulp was extirpated and transported to the Central Research Laboratory. Gingival connective tissue was collected from the participants undergoing any crown lengthening procedure or any gingivectomy procedure from the Department of Periodontology. A similar procedure was also followed for apical papilla and PDL. Isolation was done followed by the identification of the cells by immunocytochemistry using different markers. Once the identity of cells was confirmed, these cells were treated with different culture media to attain 70% to 100% confluency. Then the medium was replaced with a conditioning medium containing specific growth factors for differentiation into osteogenic, chondrogenic, and adipogenic cell lineages. Result: In our study, the number of samples collected and processed was 117. The isolation rate of stem cells from the above-collected samples was 70%. Statistical analysis—no statistical analysis was done as there was no variability expected. Conclusion: Our study showed that stem cells could be isolated, differentiated, and characterized from different dental sources.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 365
Author(s):  
Seon-Hee Shin ◽  
Hyung-Seog Yu ◽  
Jung-Yul Cha ◽  
Jae-Sung Kwon ◽  
Chung-Ju Hwang

The accurate expression of bracket prescription is important for successful orthodontic treatment. The aim of this study was to evaluate the accuracy of digital scan images of brackets produced by four intraoral scanners (IOSs) when scanning the surface of the dental model attached with different bracket materials. Brackets made from stainless steel, polycrystalline alumina, composite, and composite/stainless steel slot were considered, which have been scanned from four different IOSs (Primescan, Trios, CS3600, and i500). SEM images were used as references. Each bracket axis was set in the reference scan image, and the axis was set identically by superimposing with the IOS image, and then only the brackets were divided and analyzed. One-way analysis of variance (ANOVA) was used to compare the differences. The difference between the manufacturer’s nominal torque and bracket slot base angle was 0.39 in SEM, 1.96 in Primescan, 2.04 in Trios, and 5.21 in CS3600 (p < 0.001). The parallelism, which is the difference between the upper and lower angles of the slot wall, was 0.48 in SEM, 7.00 in Primescan, 5.52 in Trios, 6.34 in CS3600, and 23.74 in i500 (p < 0.001). This study evaluated the accuracy of the bracket only, and it must be admitted that there is some error in recognizing slots through scanning in general.


2021 ◽  
pp. 66-68
Author(s):  
Rakesh Pyla ◽  
Jai Kiran Killada ◽  
V Raja Sekhar

Aim:Endodontic retreatment is a procedure that removes the lling materials from the root canals followed by their cleaning, shaping and obturation. This in-vitro study aimed to compare and evaluate the ability of various essential oils as solvents in dissolving gutta-percha, epoxy resin, and zinc oxide eugenol (ZOE) cements. Materials and methods: A total of 28 cylindrical specimens in each group ZOE, epoxy resin, 28 ISO size 40 gutta-percha cones were prepared and divided into four groups for immersion in the different solvents, i.e. lemon oil, citronella oil, lavender oil, and TCE(Tetrachloroethylene (control)) for 5 minutes. The obturating materials dissolution in the solvents were obtained by the difference between the pre-immersion original weight and the post-immersion weight on a digital analytical scale. Data were statistically analysed by a paired t-test and Analysis of Variance (ANOVA) (p < 0.05). Results: Order of efcacy of dissolution of essential oils was found to be lemon oil > Citronella oil > Lavender oil and was highly signicant (p < 0.01). In all the solvents, Gutta-percha showed maximum dissolution (Fvalue:149.56) followed by ZOE(89.07 ) and resin sealer least (23.86). Conclusion: It can be concluded that the lemon oil can be used as a solvent for dissolving obturating materials.


2018 ◽  
Vol 8 (1) ◽  
pp. 20-26
Author(s):  
Asim Rizvi ◽  
Sean T. Fitzgerald ◽  
Kent D. Carlson ◽  
Dan Dragomir Daescu ◽  
Waleed Brinjikji ◽  
...  

Background: “Remote aspiration,” using suction from the proximal internal carotid artery (ICA) to open terminus occlusions, has been reported in small case series. However, it remains unclear whether remote aspiration is feasible for middle cerebral artery occlusions in the setting of potential inflow from communicating arteries. We performed an in vitro study to assess whether suction applied at various locations proximal to an occlusion could successfully aspirate the clot. Methods: A glass model of 4 mm inner diameter (ID) with 1 mm distal narrowing and 2 mm side branch to simulate a communicating artery was constructed. A proximal side branch was placed to simulate inflow from the proximal ICA. The impact of three different-sized catheters (ID 0.088, 0.070, and 0.056 in) on histologically different (red blood cell-cell rich, fibrin-rich, and mixed) clot analogues was tested with the catheter tip placed remotely either distal or proximal to the collateral branch. Aspiration was attempted with (1) open system (flow in both the ICA and the collateral branch, (2) flow arrest with open collateral (no flow in the ICA, but flow in the collateral branch), and (3) closed system (no flow in either the ICA or the collateral branch). The outcome was success or failure of remote aspiration. Results: For the 0.088-in catheter, remote aspiration was successful in all conditions. For the 0.070-in catheter, remote aspiration was unsuccessful without proximal flow arrest, but was successful in all other scenarios. For the 0.056-in catheter, remote aspiration was successful only with complete flow arrest. Conclusions: In a noncollapsible system, remote aspiration can be successfully achieved even in the setting of prominent branch arteries by using relatively large aspiration catheters. Proximal flow arrest may facilitate successful remote aspiration for some catheter sizes.


Sign in / Sign up

Export Citation Format

Share Document