Ultra-selective detection of sub-ppm-level benzene using Pd–SnO2 yolk–shell micro-reactors with a catalytic Co3O4 overlayer for monitoring air quality

2017 ◽  
Vol 5 (4) ◽  
pp. 1446-1454 ◽  
Author(s):  
Seong-Yong Jeong ◽  
Ji-Wook Yoon ◽  
Tae-Hyung Kim ◽  
Hyun-Mook Jeong ◽  
Chul-Soon Lee ◽  
...  

Ultra-selective and sensitive detection of benzene was achieved using Pd-loaded SnO2 yolk–shell micro-reactor sensing films coated with a catalytic Co3O4 overlayer.

The Analyst ◽  
2017 ◽  
Vol 142 (21) ◽  
pp. 4116-4123 ◽  
Author(s):  
Juan Yao ◽  
Zhang Zhang ◽  
Zhenghua Deng ◽  
Youqiang Wang ◽  
Yongcan Guo

Sensitive and selective detection of miRNA based on the toehold-mediated strand displacement reaction (SDR) and non-enzymatic catalytic hairpin reaction (CHA) recycling.


CrystEngComm ◽  
2018 ◽  
Vol 20 (25) ◽  
pp. 3609-3619 ◽  
Author(s):  
Ai-Na Dou ◽  
Li-Bo Yang ◽  
Xiao-Dan Fang ◽  
Qi Yin ◽  
Mao-Dong Li ◽  
...  

Two isostructural lanthanide–organic frameworks containing bithiophene groups can be used as fast-response fluorescent probes for the sensitive detection of nitrobenzene and Fe3+ ions through fluorescence quenching.


2018 ◽  
Vol 6 (40) ◽  
pp. 10767-10774 ◽  
Author(s):  
Bo-Young Kim ◽  
Ji-Won Yoon ◽  
Kyeorei Lim ◽  
Sung Hyun Park ◽  
Ji-Wook Yoon ◽  
...  

Ultrahigh selectivity and response to sub-ppm-level of p-xylene was achieved using CoCr2O4–Cr2O3 spheres. The unique catalytic effect and nanoscale heterojunction of CoCr2O4 and Cr2O3 provide a strategy to design high performance volatile organic compounds sensors for monitoring air quality.


Crystals ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 222
Author(s):  
Qipeng Li ◽  
Yanqiong Shen ◽  
Junsong Zhao ◽  
Zejun Zhang ◽  
Jinjie Qian

A novel terbium-tetracarboxylate framework with the 5,5’-(diazene-1,2-iyl)diisophthalic acid (H4abtc) ligand, formulated as [Tb(Habtc)(DMSO)(H2O)2]n (ZTU-5), has been synthesized and structurally characterized. ZTU-5 features a 2D-layered structure constructed by the binuclear terbium secondary building units (SBUs) and abtc4– ligand, which can be further expanded into a 3D-supramolecular framework by the hydrogen bond interactions. In addition, the magnetic and fluorescence properties of ZTU-5 are investigated and ZTU-5 exhibits highly selective and sensitive detection of nitrofurazone (NZF).


2020 ◽  
Vol 44 (19) ◽  
pp. 7954-7961
Author(s):  
Sanchita Mondal ◽  
Saikat Kumar Manna ◽  
Sudipta Pathak ◽  
Aritri Ghosh ◽  
Pallab Datta ◽  
...  

A chromogenic and “off–on” fluorogenic chemodosimeter (L) based on a naphthalene–rhodamine B derivative was designed, synthesized and characterized for the selective and sensitive detection of Au3+ ions in mixed acetonitrile aqueous media.


2016 ◽  
Vol 52 (36) ◽  
pp. 6064-6067 ◽  
Author(s):  
Yi-Ru Wang ◽  
Lei Feng ◽  
Liang Xu ◽  
Yan Li ◽  
Dan-Dan Wang ◽  
...  

A rapid-response fluorescent probeACDMwas developed for selective and sensitive detection of human albumin (HA)viabinding on a non-drug binding site.


The Analyst ◽  
2018 ◽  
Vol 143 (7) ◽  
pp. 1691-1698 ◽  
Author(s):  
Neema Pallikkarathodi Mani ◽  
Manjunatha Ganiga ◽  
Jobin Cyriac

A simple and facile strategy is developed for the selective and sensitive detection of dopamine, using luminescent MoS2 nanohybrid particles.


2018 ◽  
Vol 42 (8) ◽  
pp. 6399-6407 ◽  
Author(s):  
Satyabrat Gogoi ◽  
Raju Khan

In the current study, we report the near infrared (NIR) upconversion (in the range of 850–950 nm) properties of carbon nanoparticles and their utility as a fluorescence probe for selective and sensitive detection of glutathione (GSH).


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
J. van den Broek ◽  
S. Abegg ◽  
S. E. Pratsinis ◽  
A. T. Güntner

Abstract Methanol poisoning causes blindness, organ failure or even death when recognized too late. Currently, there is no methanol detector for quick diagnosis by breath analysis or for screening of laced beverages. Typically, chemical sensors cannot distinguish methanol from the much higher ethanol background. Here, we present an inexpensive and handheld sensor for highly selective methanol detection. It consists of a separation column (Tenax) separating methanol from interferants like ethanol, acetone or hydrogen, as in gas chromatography, and a chemoresistive gas sensor (Pd-doped SnO2 nanoparticles) to quantify the methanol concentration. This way, methanol is measured within 2 min from 1 to 1000 ppm without interference of much higher ethanol levels (up to 62,000 ppm). As a proof-of-concept, we reliably measure methanol concentrations in spiked breath samples and liquor. This could enable the realization of highly selective sensors in emerging applications such as breath analysis or air quality monitoring.


The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1414-1426
Author(s):  
Ibrahim Khalil ◽  
Wageeh A. Yehye ◽  
Nurhidayatullaili Muhd Julkapli ◽  
Abu Ali Ibn Sina ◽  
Shahrooz Rahmati ◽  
...  

Raman tag intercalated short-length DNA and dual nanoplatform based SERS DNA biosensor for the ultrasensitive and selective detection of DNA.


Sign in / Sign up

Export Citation Format

Share Document