Imaging endogenous HClO in atherosclerosis using a novel fast-response fluorescence probe

2020 ◽  
Vol 56 (17) ◽  
pp. 2598-2601 ◽  
Author(s):  
Beibei Wang ◽  
Feng Zhang ◽  
Shukun Wang ◽  
Ruijin Yang ◽  
Chonghao Chen ◽  
...  

A novel probe S-ClO was developed, which could selectively sense HClO as well as monitor HClO-induced arterial vessel inflammation.


2018 ◽  
Vol 16 (12) ◽  
pp. 2074-2082 ◽  
Author(s):  
Hongmin Jia ◽  
Shuhe Xia ◽  
Huan Feng ◽  
Qingtao Meng ◽  
Chengchen Duan ◽  
...  

The features ofDNPH-NA, including its high sensitivity, selectivity, and reliability at physiological pH, together with a rapid response, enable its successful application in the detection of endogenous HOClin vitroandin vivo.



RSC Advances ◽  
2019 ◽  
Vol 9 (28) ◽  
pp. 15926-15932
Author(s):  
Lei Jin ◽  
Xiaoxue Tan ◽  
Lihui Dai ◽  
Liqiang Sheng ◽  
Qingming Wang

A new probe, EDPC, was designed and synthesized for highly specific and sensitive detection of ClO− with a fast response time in living cells.



Polyhedron ◽  
2018 ◽  
Vol 148 ◽  
pp. 76-80 ◽  
Author(s):  
Yanping Li ◽  
Ke Jiang ◽  
Jun Zhang ◽  
Tifeng Xia ◽  
Yuanjing Cui ◽  
...  


2015 ◽  
Vol 51 (13) ◽  
pp. 2721-2724 ◽  
Author(s):  
Hongxing Zhang ◽  
Jing Liu ◽  
Yuan-Qiang Sun ◽  
Yingying Huo ◽  
Yaohua Li ◽  
...  

A mitochondria-targetable fluorescence probe, methyl(4-hydroxyphenyl)amino-substituted pyronin (1), was exploited, which could highly selectively sense peroxynitrite (ONOO−) within seconds.



Author(s):  
M.J. Kim ◽  
L.C. Liu ◽  
S.H. Risbud ◽  
R.W. Carpenter

When the size of a semiconductor is reduced by an appropriate materials processing technique to a dimension less than about twice the radius of an exciton in the bulk crystal, the band like structure of the semiconductor gives way to discrete molecular orbital electronic states. Clusters of semiconductors in a size regime lower than 2R {where R is the exciton Bohr radius; e.g. 3 nm for CdS and 7.3 nm for CdTe) are called Quantum Dots (QD) because they confine optically excited electron- hole pairs (excitons) in all three spatial dimensions. Structures based on QD are of great interest because of fast response times and non-linearity in optical switching applications.In this paper we report the first HREM analysis of the size and structure of CdTe and CdS QD formed by precipitation from a modified borosilicate glass matrix. The glass melts were quenched by pouring on brass plates, and then annealed to relieve internal stresses. QD precipitate particles were formed during subsequent "striking" heat treatments above the glass crystallization temperature, which was determined by differential thermal analysis.



The Analyst ◽  
2020 ◽  
Vol 145 (1) ◽  
pp. 122-131 ◽  
Author(s):  
Wanda V. Fernandez ◽  
Rocío T. Tosello ◽  
José L. Fernández

Gas diffusion electrodes based on nanoporous alumina membranes electrocatalyze hydrogen oxidation at high diffusion-limiting current densities with fast response times.



2020 ◽  
Author(s):  
SMITA GAJANAN NAIK ◽  
Mohammad Hussain Kasim Rabinal

Electrical memory switching effect has received a great interest to develop emerging memory technology such as memristors. The high density, fast response, multi-bit storage and low power consumption are their...





2020 ◽  
Author(s):  
Junxia Ren ◽  
Yaozu Liu ◽  
Xin Zhu ◽  
Yangyang Pan ◽  
Yujie Wang ◽  
...  

<p><a></a><a></a><a></a><a></a><a></a><a></a><a></a><a>The development of highly-sensitive recognition of </a><a></a><a></a><a></a><a></a><a>hazardous </a>chemicals, such as volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs), is of significant importance because of their widespread social concerns related to environment and human health. Here, we report a three-dimensional (3D) covalent organic framework (COF, termed JUC-555) bearing tetraphenylethylene (TPE) side chains as an aggregation-induced emission (AIE) fluorescence probe for sensitive molecular recognition.<a></a><a> </a>Due to the rotational restriction of TPE rotors in highly interpenetrated framework after inclusion of dimethylformamide (DMF), JUC-555 shows impressive AIE-based strong fluorescence. Meanwhile, owing to the large pore size (11.4 Å) and suitable intermolecular distance of aligned TPE (7.2 Å) in JUC-555, the obtained material demonstrates an excellent performance in the molecular recognition of hazardous chemicals, e.g., nitroaromatic explosives, PAHs, and even thiophene compounds, via a fluorescent quenching mechanism. The quenching constant (<i>K</i><sub>SV</sub>) is two orders of magnitude better than those of other fluorescence-based porous materials reported to date. This research thus opens 3D functionalized COFs as a promising identification tool for environmentally hazardous substances.</p>



2020 ◽  
Vol 38 (8A) ◽  
pp. 1187-1199
Author(s):  
Qaed M. Ali ◽  
Mohammed M. Ezzalden

BLDC motors are characterized by electronic commutation, which is performed by using an electric three-phase inverter. The direct control system of the BLDC motor consists of double loops; including the inner-loop for current regulating and outer-loop for speed control. The operation of the current controller requires feedback of motor currents; the conventional current controller uses two current sensors on the ac side of the inverter to measure the currents of two phases, while the third current would be accordingly calculated. These two sensors should have the same characteristics, to achieve balanced current measurements. It should be noted that the sensitivity of these sensors changes with time. In the case of one sensor fails, both of them must be replaced. To overcome this problem, it is preferable to use one sensor instead of two. The proposed control system is based on a deadbeat predictive controller, which is used to regulate the DC current of the BLDC motor. Such a controller can be considered as digital controller mode, which has fast response, high precision and can be easily implemented with microprocessor. The proposed control system has been simulated using Matlab software, and the system is tested at a different operating condition such as low speed and high speed.



Sign in / Sign up

Export Citation Format

Share Document