Enhancing the selectivity of optical sensors using synthetic transmembrane ion transporters

2020 ◽  
Vol 56 (92) ◽  
pp. 14455-14458
Author(s):  
Sarah R. Marshall ◽  
Anmol Singh ◽  
Jacqueline N. Wagner ◽  
Nathalie Busschaert

As proof-of-concept, we show that the non-selective anion sensor lucigenin can be converted to a selective iodide sensor by encapsulation into liposomes and the addition of transmembrane transporters.

Nanophotonics ◽  
2020 ◽  
Vol 9 (5) ◽  
pp. 1015-1022
Author(s):  
Sang-Eun Mun ◽  
Chulsoo Choi ◽  
Jongwoo Hong ◽  
Byoungho Lee

AbstractFano resonance, one of the interesting resonance phenomena in physics, provides versatile applications when combined with a concept of metasurface in nanophotonics. Fano-resonant metasurface (FRM) is attracting a lot of attention due to its superior narrowband characteristics as well as design freedom of metasurfaces in nanoscale. However, only the control of apparent asymmetric spectral nature of Fano resonance has been focused at applications such as optical sensors, as the amplitude feature of Fano resonances is relatively easy to control and can be measured by an experimental setup. Here, a method for modulating the phase information of FRM by both simulation and experiment is demonstrated. As a proof of concept, an optical demultiplexer, which can divide four target wavelengths in different directions of free space, is verified experimentally. It covers a broadband wavelength range of more than 350 nm in the near-infrared region with extremely small full-width at half-maximum. This approach can offer the complete control of FRM for a wide range of applications, including optical multiplexers, routers, filters, and switches, beyond conventional applications that have been limited to the amplitude control of Fano resonance.


Author(s):  
A. G. Jackson ◽  
M. Rowe

Diffraction intensities from intermetallic compounds are, in the kinematic approximation, proportional to the scattering amplitude from the element doing the scattering. More detailed calculations have shown that site symmetry and occupation by various atom species also affects the intensity in a diffracted beam. [1] Hence, by measuring the intensities of beams, or their ratios, the occupancy can be estimated. Measurement of the intensity values also allows structure calculations to be made to determine the spatial distribution of the potentials doing the scattering. Thermal effects are also present as a background contribution. Inelastic effects such as loss or absorption/excitation complicate the intensity behavior, and dynamical theory is required to estimate the intensity value.The dynamic range of currents in diffracted beams can be 104or 105:1. Hence, detection of such information requires a means for collecting the intensity over a signal-to-noise range beyond that obtainable with a single film plate, which has a S/N of about 103:1. Although such a collection system is not available currently, a simple system consisting of instrumentation on an existing STEM can be used as a proof of concept which has a S/N of about 255:1, limited by the 8 bit pixel attributes used in the electronics. Use of 24 bit pixel attributes would easily allowthe desired noise range to be attained in the processing instrumentation. The S/N of the scintillator used by the photoelectron sensor is about 106 to 1, well beyond the S/N goal. The trade-off that must be made is the time for acquiring the signal, since the pattern can be obtained in seconds using film plates, compared to 10 to 20 minutes for a pattern to be acquired using the digital scan. Parallel acquisition would, of course, speed up this process immensely.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2002 ◽  
Author(s):  
Sheri Yvonne Nottestad Boyd ◽  
Linda L. Huffer ◽  
Terry D. Bauch ◽  
James L. Furgerson

2020 ◽  
Vol 92 (1) ◽  
pp. 10906
Author(s):  
Jeroen Schoenmaker ◽  
Pâmella Gonçalves Martins ◽  
Guilherme Corsi Miranda da Silva ◽  
Julio Carlos Teixeira

Organic Rankine Cycle (ORC) systems are increasingly gaining relevance in the renewable and sustainable energy scenario. Recently our research group published a manuscript identifying a new type of thermodynamic cycle entitled Buoyancy Organic Rankine Cycle (BORC) [J. Schoenmaker, J.F.Q. Rey, K.R. Pirota, Renew. Energy 36, 999 (2011)]. In this work we present two main contributions. First, we propose a refined thermodynamic model for BORC systems accounting for the specific heat of the working fluid. Considering the refined model, the efficiencies for Pentane and Dichloromethane at temperatures up to 100 °C were estimated to be 17.2%. Second, we show a proof of concept BORC system using a 3 m tall, 0.062 m diameter polycarbonate tube as a column-fluid reservoir. We used water as a column fluid. The thermal stability and uniformity throughout the tube has been carefully simulated and verified experimentally. After the thermal parameters of the water column have been fully characterized, we developed a test body to allow an adequate assessment of the BORC-system's efficiency. We obtained 0.84% efficiency for 43.8 °C working temperature. This corresponds to 35% of the Carnot efficiency calculated for the same temperature difference. Limitations of the model and the apparatus are put into perspective, pointing directions for further developments of BORC systems.


2010 ◽  
Vol 48 (05) ◽  
Author(s):  
K Farkas ◽  
Z Rakonczay Jr ◽  
F Nagy ◽  
T Molnár ◽  
Z Szepes ◽  
...  

2012 ◽  
Vol 25 (01) ◽  
Author(s):  
A Klein ◽  
G Shafirstein ◽  
E Kohl ◽  
W Bäumler ◽  
M Landthaler ◽  
...  

Author(s):  
FV Güttler ◽  
K Winterwerber ◽  
C Gross ◽  
A Heinrich ◽  
M de Bucourt ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document