scholarly journals Development of micropillar array electrodes for highly sensitive detection of biomarkers

RSC Advances ◽  
2020 ◽  
Vol 10 (67) ◽  
pp. 41110-41119
Author(s):  
Chaozhan Chen ◽  
Bin Ran ◽  
Zhenxing Wang ◽  
Hongli Zhao ◽  
Minbo Lan ◽  
...  

PDMS-based micropillar array electrodes with increased surface area and surface modification were developed to detect biomarkers with high sensitivity.

RSC Advances ◽  
2021 ◽  
Vol 11 (39) ◽  
pp. 23975-23984
Author(s):  
Xue Yang ◽  
Yixia Ren ◽  
Hongmei Chai ◽  
Xiufang Hou ◽  
Zhixiang Wang ◽  
...  

Four fluorescent 2D Zn-MOFs based on a flexible triangular ligand and linear N-donor ligands are hydrothermally prepared and used to detect nitrobenzene in aqueous solution with high sensitivity, demonstrating their potential as fluorescent sensors.


2017 ◽  
Vol 9 (6) ◽  
pp. 1031-1037 ◽  
Author(s):  
Jingtao Liu ◽  
Yu Ding ◽  
Lifei Ji ◽  
Xin Zhang ◽  
Fengchun Yang ◽  
...  

Hexavalent chromium (Cr(vi)) is one of the most toxic heavy metal pollutants in groundwater, and thus the detection of Cr(vi) with high sensitivity, accuracy, and simplicity and low cost is of great importance.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Po Chun Chen ◽  
Sheng Jen Hsieh ◽  
Chien Chon Chen ◽  
Jun Zou

We proposed fabricating an aluminum microneedle array with a nanochannel structure on the surface by combining micromachining, electrolyte polishing, and anodization methods. The microneedle array provides a three-dimensional (3D) structure that possesses several hundred times more surface area than a traditional nanochannel template. Therefore, the microneedle array can potentially be used in many technology applications. This 3D microneedle array device can not only be used for painless injection or extraction, but also for storage, highly sensitive detection, drug delivery, and microelectrodes. From the calculation we made, the microneedle array not only increases surface area, but also enlarges the capacity of the device. Therefore, the microneedle array can further be used on many detecting, storing, or drug delivering applications.


The Analyst ◽  
2021 ◽  
Author(s):  
Ahmed Mohamed ◽  
Ryan Walsh ◽  
Mohamed Cherif ◽  
Hassan A. Hafez ◽  
Xavier Ropagnol ◽  
...  

We demonstrate the rapid and highly sensitive detection of a small molecule, microcystin-LR (MC-LR) toxin using an aptasensor based on a terahertz (THz) emission technique named the terahertz chemical microscope (TCM).


2019 ◽  
Vol 7 (8) ◽  
pp. 2327-2332 ◽  
Author(s):  
Tingting Ma ◽  
Xue Zhao ◽  
Yutaka Matsuo ◽  
Jian Song ◽  
Rui Zhao ◽  
...  

Highly sensitive detection of Fe3+ was achieved using a fluorescein-based fluorescent porous aromatic framework.


RSC Advances ◽  
2015 ◽  
Vol 5 (11) ◽  
pp. 7854-7859 ◽  
Author(s):  
Yang Peng ◽  
Ziren Yan ◽  
Ying Wu ◽  
Junwei Di

AgAuPt hybrid nanocages modified electrode showed high sensitivity for the detection of hydrogen peroxide.


2019 ◽  
Vol 6 (6) ◽  
pp. 1432-1441 ◽  
Author(s):  
Shenghong Kang ◽  
Haimin Zhang ◽  
Guozhong Wang ◽  
Yunxia Zhang ◽  
Huijun Zhao ◽  
...  

Gold nanoparticle (Au NP)-decorated-Fe2O3 nanorod arrays (AuNPs-Fe2O3) as a photoelectrode are applied to the detection of nitrite solution with a low limit of detection and high sensitivity.


2017 ◽  
Vol 53 (80) ◽  
pp. 11040-11043 ◽  
Author(s):  
Yuanyuan Sun ◽  
Hui Tian ◽  
Chenghui Liu ◽  
Yueying Sun ◽  
Zhengping Li

A target-triggered loop-mediated isothermal amplification (TT-LAMP) mechanism is developed for simple one-step but highly sensitive detection of microRNAs.


Sign in / Sign up

Export Citation Format

Share Document