A simple and innovative sample preparation method for on-site SARS-CoV-2 molecular diagnostics

The Analyst ◽  
2021 ◽  
Author(s):  
Songhyun LEE ◽  
Junkyu Song ◽  
Sanghyo Kim

Nucleic acid amplification is a widely used diagnostic tool, although it requires a relatively time-consuming and complicated extraction step. To address this issue outside the laboratory, we investigated a sample...

2013 ◽  
Vol 19 (3) ◽  
pp. 635-641 ◽  
Author(s):  
Vincent P. Klink ◽  
Giselle Thibaudeau ◽  
Ronald Altig

AbstractThe ability to isolate and perform nucleic acid analyses of individual cells is critical to studying the development of various cell types and structures. We present a novel biological sample preparation method developed for laser capture microdissection-assisted nucleic acid analysis of ultrathin cell/tissue sections. We used cells of the mitotic bed of the tadpole teeth of Lithobates sphenocephalus (Southern Leopard Frog). Cells from the mitotic beds at the base of the developing teeth series were isolated and embedded in the methacrylate resin, Technovit® 9100®. Intact cells of the mitotic beds were thin sectioned and examined by bright-field and transmission electron microscopy. The cytological and ultrastructural anatomy of the immature and progressively more mature tooth primordia appeared well preserved and intact. A developmental series of tooth primordia were isolated by laser capture microdissection (LCM). Processing of these cells for RNA showed that intact RNA could be isolated. The study demonstrates that Technovit® 9100® can be used as an embedding medium for extremely small tissues and from individual cells, a prerequisite step to LCM and nucleic acid analyses. A relatively small amount of sample material was needed for the analysis, which makes this technique ideal for cell-specific analyses when the desired cells are limited in quantity.


2020 ◽  
Author(s):  
Gert Johannes Kruger Marais ◽  
Michelle Naidoo ◽  
Nei-yuan Hsiao ◽  
Ziyaad Valley-Omar ◽  
Heidi Smuts ◽  
...  

The SARS-CoV-2 pandemic has resulted in shortages of both critical reagents for nucleic acid purification and highly trained staff as supply chains are strained by high demand, public health measures and frequent quarantining and isolation of staff. This created the need for alternate workflows with limited reliance on specialised reagents, equipment and staff. We present here the validation and implementation of such a workflow for preparing samples for downstream SARS-CoV-2 RT-PCR using liquid handling robots. The rapid sample preparation technique evaluated, which included sample centrifugation and heating prior to RT-PCR, showed a 97.37% (95% CI: 92.55-99.28%) positive percent agreement and 97.30% (95% CI: 90.67-99.52%) negative percent agreement compared to nucleic acid purification-based testing. This method was subsequently adopted as the primary sample preparation method in the Groote Schuur Hospital Virology Diagnostic Laboratory in Cape Town, South Africa.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Swaminathan Subramanian ◽  
Khiem Ly ◽  
Tony Chrastecky

Abstract Visualization of dopant related anomalies in integrated circuits is extremely challenging. Cleaving of the die may not be possible in practical failure analysis situations that require extensive electrical fault isolation, where the failing die can be submitted of scanning probe microscopy analysis in various states such as partially depackaged die, backside thinned die, and so on. In advanced technologies, the circuit orientation in the wafer may not align with preferred crystallographic direction for cleaving the silicon or other substrates. In order to overcome these issues, a focused ion beam lift-out based approach for site-specific cross-section sample preparation is developed in this work. A directional mechanical polishing procedure to produce smooth damage-free surface for junction profiling is also implemented. Two failure analysis applications of the sample preparation method to visualize junction anomalies using scanning microwave microscopy are also discussed.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2277
Author(s):  
Piotr M. Kuś ◽  
Igor Jerković

Recently, we proposed a new sample preparation method involving reduced solvent and sample usage, based on dehydration homogeneous liquid–liquid extraction (DHLLE) for the screening of volatiles and semi-volatiles from honey. In the present research, the method was applied to a wide range of honeys (21 different representative unifloral samples) to determine its suitability for detecting characteristic honey compounds from different chemical classes. GC-FID/MS disclosed 130 compounds from different structural and chemical groups. The DHLLE method allowed the extraction and identification of a wide range of previously reported specific and nonspecific marker compounds belonging to different chemical groups (including monoterpenes, norisoprenoids, benzene derivatives, or nitrogen compounds). For example, DHLLE allowed the detection of cornflower honey chemical markers: 3-oxo-retro-α-ionols, 3,4-dihydro-3-oxoedulan, phenyllactic acid; coffee honey markers: theobromine and caffeine; linden honey markers: 4-isopropenylcyclohexa-1,3-diene-1-carboxylic acid and 4-(2-hydroxy-2-propanyl)cyclohexa-1,3-diene-1-carboxylic acid, as well as furan derivatives from buckwheat honey. The obtained results were comparable with the previously reported data on markers of various honey varieties. Considering the application of much lower volumes of very common reagents, DHLLE may provide economical and ecological advantages as an alternative sample preparation method for routine purposes.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2350
Author(s):  
Jianing Zhang ◽  
Fengjie Yu ◽  
Yunmin Tao ◽  
Chunping Du ◽  
Wenchao Yang ◽  
...  

In the present work, a novel sample preparation method, micro salting-out assisted matrix solid-phase dispersion (μ-SOA-MSPD), was developed for the determination of bisphenol A (BPA) and bisphenol B (BPB) contaminants in bee pollen. The proposed method was designed to combine two classical sample preparation methodologies, matrix solid-phase dispersion (MSPD) and homogenous liquid-liquid extraction (HLLE), to simplify and speed-up the preparation process. Parameters of μ-SOA-MSPD were systematically investigated, and results indicated the significant effect of salt and ACN-H2O extractant on the signal response of analytes. In addition, excellent clean-up ability in removing matrix components was observed when primary secondary amine (PSA) sorbent was introduced into the blending operation. The developed method was fully validated, and the limits of detection for BPA and BPB were 20 μg/kg and 30 μg/kg, respectively. Average recoveries and precisions were ranged from 83.03% to 94.64% and 1.76% to 5.45%, respectively. This is the first report on the analysis of bisphenol contaminants in bee pollen sample, and also on the combination of MSPD and HLLE. The present method might provide a new strategy for simple and fast sample preparation of solid and semi-solid samples.


Sign in / Sign up

Export Citation Format

Share Document