Hearing-Aid Performance and Hearing-Aid Selection

1966 ◽  
Vol 9 (1) ◽  
pp. 136-149 ◽  
Author(s):  
James Jerger ◽  
Charles Speaks ◽  
Carolyn Malmquist

A sentence intelligibility test was used to evaluate listener performance with three hearing aids differing substantially in physical characteristics. Thirty six hard-of-hearing listeners, representing various types and degrees of hearing loss, were tested. Results showed that, although the sentence intelligibility test reflected meaningful average differences among the aids, the rank ordering of aids was essentially equivalent for all listeners.

1966 ◽  
Vol 9 (2) ◽  
pp. 253-258 ◽  
Author(s):  
James Jerger ◽  
Carolyn Malmquist ◽  
Charles Speaks

A sentence intelligibility test and three monosyllabic word intelligibility tests, recorded through three hearing aids, were presented to 36 subjects with diverse types of hearing loss. Although hearing aids were rank ordered meaningfully on the sentence intelligibility test-in inverse proportion to the harmonic distortion-performance differences were not systematically reflected in the monosyllabic word test results.


2019 ◽  
Vol 28 (2) ◽  
pp. 274-284 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser ◽  
Louise Hickson ◽  
Carly Meyer

Purpose Hearing loss self-management refers to the knowledge and skills people use to manage the effects of hearing loss on all aspects of their daily lives. The purpose of this study was to investigate the relationship between self-reported hearing loss self-management and hearing aid benefit and satisfaction. Method Thirty-seven adults with hearing loss, all of whom were current users of bilateral hearing aids, participated in this observational study. The participants completed self-report inventories probing their hearing loss self-management and hearing aid benefit and satisfaction. Correlation analysis was used to investigate the relationship between individual domains of hearing loss self-management and hearing aid benefit and satisfaction. Results Participants who reported better self-management of the effects of their hearing loss on their emotional well-being and social participation were more likely to report less aided listening difficulty in noisy and reverberant environments and greater satisfaction with the effect of their hearing aids on their self-image. Participants who reported better self-management in the areas of adhering to treatment, participating in shared decision making, accessing services and resources, attending appointments, and monitoring for changes in their hearing and functional status were more likely to report greater satisfaction with the sound quality and performance of their hearing aids. Conclusion Study findings highlight the potential for using information about a patient's hearing loss self-management in different domains as part of clinical decision making and management planning.


2008 ◽  
Vol 18 (1) ◽  
pp. 4-9 ◽  
Author(s):  
Leisha Eiten ◽  
Dawna Lewis

Background: For children with hearing loss, the benefits of FM systems in overcoming deleterious effects of noise, distance, and reverberation have led to recommendations for use beyond classroom settings. It is important that audiologists who recommend and fit these devices understand the rationale and procedures underlying fitting and verification. Objectives: This article reviews previousguidelines for FM verification, addresses technological advances, and introduces verification procedures appropriate for current FM and hearing-aid technology. Methods: Previous guidelines for verification of FM systems are reviewed. Those recommendations that are appropriate for current technology are addressed, as are procedures that are no longer adequate for hearing aids and FM systems utilizing more complex processing than in the past. Technological advances are discussed, and an updated approach to FM verification is proposed. Conclusions: Approaches to verification andfitting of FM systems must keep pace with advances in hearing-aid and FM technology. The transparency approach addressed in this paper is recommended for verification of FM systems coupled to hearing aids.


1968 ◽  
Vol 11 (1) ◽  
pp. 204-218 ◽  
Author(s):  
Elizabeth Dodds ◽  
Earl Harford

Persons with a high frequency hearing loss are difficult cases for whom to find suitable amplification. We have experienced some success with this problem in our Hearing Clinics using a specially designed earmold with a hearing aid. Thirty-five cases with high frequency hearing losses were selected from our clinical files for analysis of test results using standard, vented, and open earpieces. A statistical analysis of test results revealed that PB scores in sound field, using an average conversational intensity level (70 dB SPL), were enhanced when utilizing any one of the three earmolds. This result was due undoubtedly to increased sensitivity provided by the hearing aid. Only the open earmold used with a CROS hearing aid resulted in a significant improvement in discrimination when compared with the group’s unaided PB score under earphones or when comparing inter-earmold scores. These findings suggest that the inclusion of the open earmold with a CROS aid in the audiologist’s armamentarium should increase his flexibility in selecting hearing aids for persons with a high frequency hearing loss.


2020 ◽  
Author(s):  
Willy Nguyen ◽  
Miseung Koo ◽  
Seung Ha Oh ◽  
Jun Ho Lee ◽  
Moo Kyun Park

BACKGROUND Underuse of hearing aids is caused by several factors, including the stigma associated with hearing disability, affordability, and lack of awareness of rising hearing impairment associated with the growing population. Thus, there is a significant opportunity for the development of direct-to-consumer devices. For the past few years, smartphone-based hearing-aid apps have become more numerous and diverse, but few studies have investigated them. OBJECTIVE This study aimed to elucidate the electroacoustic characteristics and potential user benefits of a selection of currently available hearing-aid apps. METHODS We investigated the apps based on hearing-aid control standards (American National Standards Institute) using measurement procedures from previous studies. We categorized the apps and excluded those we considered inefficient. We investigated a selection of user-friendly, low-end apps, EarMachine and Sound Amplifier, with warble-tone audiometry, word recognition testing in unaided and aided conditions, and hearing-in-noise test in quiet and noise-front conditions in a group of users with mild hearing impairment (n = 7) as a pilot for a future long-term investigation. Results from the apps were compared with those of a conventional hearing aid. RESULTS Five of 14 apps were considered unusable based on low scores in several metrics, while the others varied across the range of electroacoustic measurements. The apps that we considered “high end” that provided lower processing latencies and audiogram-based fitting algorithms were superior overall. The clinical performance of the listeners tended to be better when using hearing aid, while the low end hearing-aid apps had limited benefits on the users. CONCLUSIONS Some apps showed the potential to benefit users with limited cases of minimal or mild hearing loss if the inconvenience of relatively poor electroacoustic performance did not outweigh the benefits of amplification.


1999 ◽  
Vol 8 (1) ◽  
pp. 40-46 ◽  
Author(s):  
Melisa R. Ellis ◽  
Michael K. Wynne

The loudness growth in 1/2-octave bands (LGOB) procedure has been shown previously to provide valid estimates of loudness growth for adults with normal hearing and those with hearing loss (Allen, Hall, & Jeng, 1990), and it has been widely incorporated into fitting strategies for adult hearing aid users by a hearing aid manufacturer. Here, we applied a simple modification of LGOB to children and adults with normal hearing and then compared the loudness growth functions (as obtained from end-point data) between the two age groups. In addition, reliability data obtained within a single session and between test sessions were compared between the two groups. Large differences were observed in the means between the two groups for the lower boundary values, the upper boundary values, and the range between boundaries both within and across all frequencies. The data obtained from children also had greater variance than the adult data. In addition, there was more variability in the data across test sessions for children. Many test-retest differences for children exceeded 10 dB. Adult test-retest differences were generally less than 10 dB. Although the LGOB with the modifications used in this study may be used to measure loudness growth in children, its poor reliability with this age group may limit its clinical use for children with hearing loss. Additional work is needed to explore whether loudness growth measures can be adapted successfully to children and whether these measures contribute worthwhile information for fitting hearing aids to children.


2017 ◽  
Vol 28 (10) ◽  
pp. 883-892 ◽  
Author(s):  
Samantha J. Gustafson ◽  
Todd A. Ricketts ◽  
Anne Marie Tharpe

Background: Consistency of hearing aid and remote microphone system use declines as school-age children with hearing loss age. One indicator of hearing aid use time is data logging, another is parent report. Recent data suggest that parents overestimate their children’s hearing aid use time relative to data logging. The potential reasons for this disparity remain unclear. Because school-age children spend the majority of their day away from their parents and with their teachers, reports from teachers might serve as a valuable and additional tool for estimating hearing aid use time and management. Purpose: This study expands previous research on factors influencing hearing aid use time in school-age children using data logging records. Discrepancies between data logging records and parent reports were explored using custom surveys designed for parents and teachers. Responses from parents and teachers were used to examine hearing aid use, remote microphone system use, and hearing aid management in school-age children. Study Sample: Thirteen children with mild-to-moderate hearing loss between the ages of 7 and 10 yr and their parents participated in this study. Teachers of ten of these children also participated. Data Collection and Analysis: Parents and teachers of children completed written surveys about each child’s hearing aid use, remote microphone system use, and hearing aid management skills. Data logs were read from hearing aids using manufacturer’s software. Multiple linear regression analysis and an intraclass correlation coefficient were used to examine factors influencing hearing aid use time and parent agreement with data logs. Parent report of hearing aid use time was compared across various activities and school and nonschool days. Survey responses from parents and teachers were compared to explore areas requiring potential improvement in audiological counseling. Results: Average daily hearing aid use time was ˜6 hr per day as recorded with data logging technology. Children exhibiting greater degrees of hearing loss and those with poorer vocabulary were more likely to use hearing aids consistently than children with less hearing loss and better vocabulary. Parents overestimated hearing aid use by ˜1 hr per day relative to data logging records. Parent-reported use of hearing aids varied across activities but not across school and nonschool days. Overall, parents and teachers showed excellent agreement on hearing aid and remote microphone system use during school instruction but poor agreement when asked about the child’s ability to manage their hearing devices independently. Conclusions: Parental reports of hearing aid use in young school-age children are largely consistent with data logging records and with teacher reports of hearing aid use in the classroom. Audiologists might find teacher reports helpful in learning more about children’s hearing aid management and remote microphone system use during their time at school. This supplementary information can serve as an additional counseling tool to facilitate discussion about remote microphone system use and hearing aid management in school-age children with hearing loss.


2014 ◽  
Vol 23 (2) ◽  
pp. 91-104 ◽  
Author(s):  
Sophie E. Ambrose ◽  
Lauren M. Unflat Berry ◽  
Elizabeth A. Walker ◽  
Melody Harrison ◽  
Jacob Oleson ◽  
...  

Purpose The purpose of the study was to (a) compare the speech sound production abilities of 2-year-old children who are hard of hearing (HH) to children with normal hearing (NH), (b) identify sources of risk for individual children who are HH, and (c) determine whether speech sound production skills at age 2 were predictive of speech sound production skills at age 3. Method Seventy children with bilateral, mild-to-severe hearing loss who use hearing aids and 37 age- and socioeconomic status–matched children with NH participated. Children's speech sound production abilities were assessed at 2 and 3 years of age. Results At age 2, the HH group demonstrated vowel production abilities on par with their NH peers but weaker consonant production abilities. Within the HH group, better outcomes were associated with hearing aid fittings by 6 months of age, hearing loss of less than 45 dB HL, stronger vocabulary scores, and being female. Positive relationships existed between children's speech sound production abilities at 2 and 3 years of age. Conclusion Assessment of early speech sound production abilities in combination with demographic, audiologic, and linguistic variables may be useful in identifying HH children who are at risk for delays in speech sound production.


2008 ◽  
Vol 123 (5) ◽  
pp. 555-557 ◽  
Author(s):  
J M Bernstein ◽  
P Z Sheehan

AbstractObjective:Bone-anchored hearing aid surgery in younger children is a two-stage procedure, with a titanium fixture being allowed to osseointegrate for several months before an abutment is fitted through a skin graft. In the first procedure, it has been usual to place a reserve or sleeper fixture approximately 5 mm from the primary fixture as a backup in case the primary fixture fails to osseointegrate. This ipsilateral sleeper fixture is expensive, is often not used, and is placed in thinner calvarial bone where it is less likely to osseointegrate successfully. The authors have implanted the sleeper fixture on the contralateral side, with the additional objective of reducing the number of procedures for bilateral bone-anchored hearing aid implantation, providing a cost-effective use for the sleeper.Methods:The authors implanted the bone-anchored hearing aid sleeper fixture in the contralateral temporal bone instead of on the ipsilateral side in seven successive paediatric cases with bilateral conductive hearing loss requiring two-stage bone-anchored hearing aids, treated at the Royal Manchester Children's Hospital, UK.Results:The seven patients ranged in age from five to 15 years, with a mean age of 10 years; in addition, a 20-year-old with learning disability was also treated. In each case, the contralateral sleeper fixture was not needed as a backup fixture, but was used in four patients (57 per cent) as the basis for a second-side bone-anchored hearing aid.Conclusions:In children with bilateral conductive hearing loss, in whom a bilateral bone-anchored hearing aid is being considered and the second side is to be operated upon at a later date, we recommend placing the sleeper fixture on the contralateral side at the time of primary first-side surgery. Our technique provides a sleeper fixture located in an optimal position, where it also offers the option of use for a second-side bone-anchored hearing aid and reduces the number of procedures needed.


2002 ◽  
Vol 13 (09) ◽  
pp. 503-520
Author(s):  
Francis Kuk ◽  
Andre Marcoux

Ensuring consistent audibility is an important objective when fitting hearing aids to children. This article reviews the factors that could affect the audibility of the speech signals to children. These factors range from a precise determination of the child's hearing loss to an accurate specification of gain in the chosen hearing aids. In addition, hearing aid technology and features such as multichannel processing, directional microphones, and feedback cancellation that could affect the achievement of consistent audibility are reviewed.


Sign in / Sign up

Export Citation Format

Share Document