scholarly journals Indoor Air Quality Evaluation of Commercial Buildings In Kuantan

2018 ◽  
Vol 225 ◽  
pp. 05018
Author(s):  
Noor Huwaida Yahaya ◽  
Ftwi Yohaness Hagos ◽  
Mohamad Firdaus Basrawi

This work focuses on indoor air quality evaluation of commercial buildings in Kuantan. Some buildings have been selected to monitor indoor air quality. The research has been carried out only in Kuantan, which focused on hotels and government buildings. Some sample measurements were taken which include air temperature, relative humidity, and air movement, carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), respirable particulate matter (PM 10), formaldehyde and total volatile organic compound (TVOC). In addition, questionnaires were conducted on a number of workers in each building to determine the level of health and illness caused by air in the building where they work. Hence, this study has analyzed the link between the questioner results and the results of indoor air measurements that were carried out. From surveys, it appears there are four buildings that have low air flow, four buildings have a lot of dust and five buildings have a high temperature. In contrast, four buildings have a good indoor air quality.

10.14311/492 ◽  
2003 ◽  
Vol 43 (6) ◽  
Author(s):  
M. V. Jokl

Human physiology research makes evident that the Weber-Fechner law applies not only to noise perception but also to the perception of other environmental components. Based on this fact, new decibel units for dor component representing indoor air quality in majority locations have been proposed: decicarbdiox dCd (for carbon dioxide CO2) and decitvoc dTv (for total volatile organic compound TVOC). Equations of these new units have been proved by application of a) experimental relationships between odor intensity (representing odor perception by the human body) and odor concentrations of CO2 and TVOC, b) individually  measured CO2 and TVOC levels (concentrations) – from these new decibel units can be calculated and their values compared with decibel units of noise measured in the same locations. The undoubted benefit of using the decibel scale is that it gives much better approximation to human perception of odor intensity compared to the CO2 and TVOC concentration scales.


Author(s):  
Camilla Vornanen-Winqvist ◽  
Kati Järvi ◽  
Maria A. Andersson ◽  
Kaiser Ahmed ◽  
Sander Toomla ◽  
...  

This paper describes a case study of ventilation as well as measured and perceived indoor air quality (IAQ) in a Finnish comprehensive school with a hybrid ventilation system and reported IAQ problems. An operational error was found when investigating the ventilation system that prevented air from coming into classrooms, except for short periods of high carbon dioxide (CO2) concentrations. However, results indicated that hybrid ventilation system was able to provide adequate ventilation and sufficient IAQ once properly designed and maintained. After ventilation operation was improved, occupants reported less unpleasant odors and stuffy air. The amount of total volatile organic compounds (TVOC) and some single volatile organic compounds (VOCs) decreased. Indoor mycobiota was observed in settled dust in the classrooms, from which ventilation improvement eliminated the dominant, opportunistic human pathogen species Trichoderma citrinoviride found before improvement.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 250
Author(s):  
Chuloh Jung ◽  
Jihad Awad

Due to unprecedented urbanization, UAE had built many new residential projects with poor choices of material and ventilation. This social phenomenon is leading UAE to Sick Building Syndrome (SBS) faster than any other countries. The Dubai Municipality regulates the indoor air quality with strict stipulation, but the detailed regulations are still insufficient. The objective of this paper is to measure the indoor air quality of new residential projects in Dubai to suggest the improvement of the regulations for indoor air quality. As a methodology, a field survey was conducted to investigate the status of indoor air pollution in residential buildings. Based on the field survey data, lab experiments for building materials were conducted and a computer simulation on radon gas was conducted. The result had shown that radon gas was mainly detected in new townhouses and labor camp houses, and its concentration was found to exceed the standard. Volatile organic solvents (VOCs) and formaldehyde (CH2O) were mainly detected in showhouses and new townhouses, and the concentration distribution was about 10 times higher than that of outdoors. It was proven that emission concentration of radon gas from various building materials were detected, and the order was red clay, gypsum board, and concrete. Volatile organic solvents (VOCs) are mainly detected in oil paints and PVC floor and the radiation amount of all pollutants increased with temperature increase. In computer simulation, it was found that a new townhouse needs a grace period from 20 days to 6 months to lower the radon gas concentration by 2 pCi/L. This study will serve as a basic data to establish more detailed regulation for the building materials and improve the IAQ standards in Dubai.


2021 ◽  
Author(s):  
Kamrie Sarnosky ◽  
Mark Benden ◽  
Leslie Cizmas ◽  
Annette Regan ◽  
Garett Sansom

Abstract Background: The COVID-19 pandemic has accelerated an already existing trend of individuals increasingly working remotely. With the growing popularity of remote working, specifically in a home office, there is a critical need to better understand and characterize the potential environmental differences between these two spaces. Indoor air pollution can have adverse health effects and impair cognitive functioning. Methods: This small pilot cohort study (N=22) recruited home and office workers to better understand the indoor air quality between these spaces. Air contaminants collected and assessed included PM10 and PM2.5, carbon dioxide (CO2), and total volatile organic compounds (TVOCs). Results: Findings showed a strong statistically significant increase in all measured variables within homes in comparison to traditional offices (p<0.001). For instance, The mean PM2.5 level in the traditional office space was 1.93 µg/m3 whereas it was more than twice this amount (5.97 µg/m3) in home offices.Conclusion: These results indicate that those who work from home are at increased risk due to longer exposures to higher levels of certain contaminants, the importance to better develop interventions to mitigate this reality is underscored by the fact that many workers will be moving to home-based offices in the coming years.


2015 ◽  
Vol 2 (1) ◽  
pp. 70 ◽  
Author(s):  
Feng-Chyi Duh

This study investigated transient effects on the air quality of parked cars and moving cars with and without operating air conditioning. Carbon dioxide, carbon monoxide, volatile organic compounds, and formaldehyde concentrations were measured for comparative analysis. The results showed that simply changing the air conditioning system from internal circulation to external circulation to introduce air from outside reduces carbon dioxide concentrations by more than 50%, volatile organic compound concentrations by more than 77%, and the heat index from 0.1℃/min to less than 0.05 ℃/min. In order to conserve energy and improve car indoor air quality, this study can serve as a reference on healthy car environments.


2017 ◽  
Vol 112 ◽  
pp. 261-268 ◽  
Author(s):  
Sorin Cociorva ◽  
Andreea Iftene

Sign in / Sign up

Export Citation Format

Share Document